Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle
Background This study aims to evaluate the accuracy of volumetric measurements of three-dimensional (3D)-printed human condyles from cone-beam computed tomography (CBCT) in comparison to physical condyles using a water displacement test. Methodology A sample of 22 dry condyles was separated from the...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10631571/ https://www.ncbi.nlm.nih.gov/pubmed/38022326 http://dx.doi.org/10.7759/cureus.46746 |
_version_ | 1785132389797724160 |
---|---|
author | Elrawdy, Ahmed M Amer, Mohamed E Algariah, Ahmed K Eid, Mohamed H Abu-Elsaoud, Abdelghafar M Ghoneim, Mohamed M |
author_facet | Elrawdy, Ahmed M Amer, Mohamed E Algariah, Ahmed K Eid, Mohamed H Abu-Elsaoud, Abdelghafar M Ghoneim, Mohamed M |
author_sort | Elrawdy, Ahmed M |
collection | PubMed |
description | Background This study aims to evaluate the accuracy of volumetric measurements of three-dimensional (3D)-printed human condyles from cone-beam computed tomography (CBCT) in comparison to physical condyles using a water displacement test. Methodology A sample of 22 dry condyles was separated from the mandibular body by disc, mounted on a base made of casting wax, and scanned using the SCANORA (Scanora 3DX, Soredex, Finland) CBCT scanner. Subsequently, the projection data were reconstructed with the machine-dedicated OnDemand 3D (Cybermed Co., Seoul, Korea). The Standard Tessellation Language file was prepared for 3D printing using chitubox slicing software v1.9.1. Frozen water-washable gray resin was used for 3D printing. All condyles were printed using the same parameters and the same resin. The volumetric measurements were then performed using a customized modified pycnometer based on water volume and weight displacement. Volumetric measures were performed for both the physical human condyles and the 3D-printed replicas and the measurements were then compared. Results The volume of dry condyles using the water displacement method showed an average (±SD) of 1.925 ± 0.40 cm(3). However, the volume of 3D-printed replicas using the water displacement method showed an average (±SD) of 2.109 ± 0.40 cm(3). The differences in measurements were insignificant (p > 0.05), as revealed by an independent t-test. Conclusions Highly precise, accurate, and reliable CBCT for volumetric mandibular condyle was applied for measurements of a human condyle and 3D-printed replica. The modified pycnometer for volumetric measurements presented an excellent volumetric measure based on a simple water displacement device. The tested modified pycnometer can be applied in volumetric measurements in both 3D-printed and mandibular condyle. For best accuracy, the highest scanning resolution possible should be used. As it directly handles irregularly shaped solid objects in a non-destructive manner with a high level of precision and reliability, this 3D scanning approach may be seen as a superior alternative to the current measurement methods. |
format | Online Article Text |
id | pubmed-10631571 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-106315712023-10-09 Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle Elrawdy, Ahmed M Amer, Mohamed E Algariah, Ahmed K Eid, Mohamed H Abu-Elsaoud, Abdelghafar M Ghoneim, Mohamed M Cureus Dentistry Background This study aims to evaluate the accuracy of volumetric measurements of three-dimensional (3D)-printed human condyles from cone-beam computed tomography (CBCT) in comparison to physical condyles using a water displacement test. Methodology A sample of 22 dry condyles was separated from the mandibular body by disc, mounted on a base made of casting wax, and scanned using the SCANORA (Scanora 3DX, Soredex, Finland) CBCT scanner. Subsequently, the projection data were reconstructed with the machine-dedicated OnDemand 3D (Cybermed Co., Seoul, Korea). The Standard Tessellation Language file was prepared for 3D printing using chitubox slicing software v1.9.1. Frozen water-washable gray resin was used for 3D printing. All condyles were printed using the same parameters and the same resin. The volumetric measurements were then performed using a customized modified pycnometer based on water volume and weight displacement. Volumetric measures were performed for both the physical human condyles and the 3D-printed replicas and the measurements were then compared. Results The volume of dry condyles using the water displacement method showed an average (±SD) of 1.925 ± 0.40 cm(3). However, the volume of 3D-printed replicas using the water displacement method showed an average (±SD) of 2.109 ± 0.40 cm(3). The differences in measurements were insignificant (p > 0.05), as revealed by an independent t-test. Conclusions Highly precise, accurate, and reliable CBCT for volumetric mandibular condyle was applied for measurements of a human condyle and 3D-printed replica. The modified pycnometer for volumetric measurements presented an excellent volumetric measure based on a simple water displacement device. The tested modified pycnometer can be applied in volumetric measurements in both 3D-printed and mandibular condyle. For best accuracy, the highest scanning resolution possible should be used. As it directly handles irregularly shaped solid objects in a non-destructive manner with a high level of precision and reliability, this 3D scanning approach may be seen as a superior alternative to the current measurement methods. Cureus 2023-10-09 /pmc/articles/PMC10631571/ /pubmed/38022326 http://dx.doi.org/10.7759/cureus.46746 Text en Copyright © 2023, Elrawdy et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Dentistry Elrawdy, Ahmed M Amer, Mohamed E Algariah, Ahmed K Eid, Mohamed H Abu-Elsaoud, Abdelghafar M Ghoneim, Mohamed M Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle |
title | Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle |
title_full | Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle |
title_fullStr | Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle |
title_full_unstemmed | Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle |
title_short | Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle |
title_sort | appraisal of the accuracy and reliability of cone-beam computed tomography and three-dimensional printing for volumetric mandibular condyle measurements of a human condyle |
topic | Dentistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10631571/ https://www.ncbi.nlm.nih.gov/pubmed/38022326 http://dx.doi.org/10.7759/cureus.46746 |
work_keys_str_mv | AT elrawdyahmedm appraisaloftheaccuracyandreliabilityofconebeamcomputedtomographyandthreedimensionalprintingforvolumetricmandibularcondylemeasurementsofahumancondyle AT amermohamede appraisaloftheaccuracyandreliabilityofconebeamcomputedtomographyandthreedimensionalprintingforvolumetricmandibularcondylemeasurementsofahumancondyle AT algariahahmedk appraisaloftheaccuracyandreliabilityofconebeamcomputedtomographyandthreedimensionalprintingforvolumetricmandibularcondylemeasurementsofahumancondyle AT eidmohamedh appraisaloftheaccuracyandreliabilityofconebeamcomputedtomographyandthreedimensionalprintingforvolumetricmandibularcondylemeasurementsofahumancondyle AT abuelsaoudabdelghafarm appraisaloftheaccuracyandreliabilityofconebeamcomputedtomographyandthreedimensionalprintingforvolumetricmandibularcondylemeasurementsofahumancondyle AT ghoneimmohamedm appraisaloftheaccuracyandreliabilityofconebeamcomputedtomographyandthreedimensionalprintingforvolumetricmandibularcondylemeasurementsofahumancondyle |