Cargando…

Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report

BACKGROUND: We previously reported a case of successful percutaneous left atrial appendage closure (LAAC) for complex left atrial appendage (LAA) morphology using a handmade double-curve delivery sheath (DS) reshaped by a heat gun. However, whether the reshaped curve was appropriately adjusted as an...

Descripción completa

Detalles Bibliográficos
Autores principales: Shimura, Tetsuro, Higami, Hirooki, Matsuo, Hitoshi, Yamamoto, Masanori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633782/
https://www.ncbi.nlm.nih.gov/pubmed/37954569
http://dx.doi.org/10.1093/ehjcr/ytad503
_version_ 1785132689344430080
author Shimura, Tetsuro
Higami, Hirooki
Matsuo, Hitoshi
Yamamoto, Masanori
author_facet Shimura, Tetsuro
Higami, Hirooki
Matsuo, Hitoshi
Yamamoto, Masanori
author_sort Shimura, Tetsuro
collection PubMed
description BACKGROUND: We previously reported a case of successful percutaneous left atrial appendage closure (LAAC) for complex left atrial appendage (LAA) morphology using a handmade double-curve delivery sheath (DS) reshaped by a heat gun. However, whether the reshaped curve was appropriately adjusted as an optimal configuration for this patient’s anatomy remained uncertain. CASE SUMMARY: We established the LAAC procedural simulation model supported by virtual reality (VR) technology. With this VR simulator, the patient’s whole heart model with venous access route and atrial septal puncture point of foramen ovale (FO) could be replicated based on the pre-procedural computed tomography image. Multiple views of the VR image provided a deep understanding of the patient-specific anatomy. Additionally, the operators were enabled to perform the virtual LAAC procedure using VR-derived LAAC devices, including various DS types. In the VR simulator, the manually reshaped DS showed better co-axiality from the FO to the LAA orifice than the conventional double-curve DS, resulting in the successful deployment inside the LAA of the VR simulator. However, the perpendicularity of the device towards the LAA orifice of the handmade reshaped DS remained insufficient. The VR simulator suggested that the ideal curve of the DS needed to change relatively posteriorly and have a more aggressive inferior slide than the previously reshaped DS. DISCUSSION: The post-procedural review of the VR simulator confirmed that the sheath reshaping technique helped ensure successful LAAC. Pre-procedural VR simulation may be useful for procedural planning that includes DS reshaping for patients with challenging anatomy undergoing LAAC.
format Online
Article
Text
id pubmed-10633782
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-106337822023-11-10 Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report Shimura, Tetsuro Higami, Hirooki Matsuo, Hitoshi Yamamoto, Masanori Eur Heart J Case Rep Case Report BACKGROUND: We previously reported a case of successful percutaneous left atrial appendage closure (LAAC) for complex left atrial appendage (LAA) morphology using a handmade double-curve delivery sheath (DS) reshaped by a heat gun. However, whether the reshaped curve was appropriately adjusted as an optimal configuration for this patient’s anatomy remained uncertain. CASE SUMMARY: We established the LAAC procedural simulation model supported by virtual reality (VR) technology. With this VR simulator, the patient’s whole heart model with venous access route and atrial septal puncture point of foramen ovale (FO) could be replicated based on the pre-procedural computed tomography image. Multiple views of the VR image provided a deep understanding of the patient-specific anatomy. Additionally, the operators were enabled to perform the virtual LAAC procedure using VR-derived LAAC devices, including various DS types. In the VR simulator, the manually reshaped DS showed better co-axiality from the FO to the LAA orifice than the conventional double-curve DS, resulting in the successful deployment inside the LAA of the VR simulator. However, the perpendicularity of the device towards the LAA orifice of the handmade reshaped DS remained insufficient. The VR simulator suggested that the ideal curve of the DS needed to change relatively posteriorly and have a more aggressive inferior slide than the previously reshaped DS. DISCUSSION: The post-procedural review of the VR simulator confirmed that the sheath reshaping technique helped ensure successful LAAC. Pre-procedural VR simulation may be useful for procedural planning that includes DS reshaping for patients with challenging anatomy undergoing LAAC. Oxford University Press 2023-10-09 /pmc/articles/PMC10633782/ /pubmed/37954569 http://dx.doi.org/10.1093/ehjcr/ytad503 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Shimura, Tetsuro
Higami, Hirooki
Matsuo, Hitoshi
Yamamoto, Masanori
Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report
title Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report
title_full Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report
title_fullStr Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report
title_full_unstemmed Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report
title_short Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report
title_sort appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633782/
https://www.ncbi.nlm.nih.gov/pubmed/37954569
http://dx.doi.org/10.1093/ehjcr/ytad503
work_keys_str_mv AT shimuratetsuro appropriateassessmentusingvirtualrealitysimulationforanovelreshapedcurvesheathduringpercutaneousleftatrialappendageclosureafollowupcasereport
AT higamihirooki appropriateassessmentusingvirtualrealitysimulationforanovelreshapedcurvesheathduringpercutaneousleftatrialappendageclosureafollowupcasereport
AT matsuohitoshi appropriateassessmentusingvirtualrealitysimulationforanovelreshapedcurvesheathduringpercutaneousleftatrialappendageclosureafollowupcasereport
AT yamamotomasanori appropriateassessmentusingvirtualrealitysimulationforanovelreshapedcurvesheathduringpercutaneousleftatrialappendageclosureafollowupcasereport