Cargando…
Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report
BACKGROUND: We previously reported a case of successful percutaneous left atrial appendage closure (LAAC) for complex left atrial appendage (LAA) morphology using a handmade double-curve delivery sheath (DS) reshaped by a heat gun. However, whether the reshaped curve was appropriately adjusted as an...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633782/ https://www.ncbi.nlm.nih.gov/pubmed/37954569 http://dx.doi.org/10.1093/ehjcr/ytad503 |
_version_ | 1785132689344430080 |
---|---|
author | Shimura, Tetsuro Higami, Hirooki Matsuo, Hitoshi Yamamoto, Masanori |
author_facet | Shimura, Tetsuro Higami, Hirooki Matsuo, Hitoshi Yamamoto, Masanori |
author_sort | Shimura, Tetsuro |
collection | PubMed |
description | BACKGROUND: We previously reported a case of successful percutaneous left atrial appendage closure (LAAC) for complex left atrial appendage (LAA) morphology using a handmade double-curve delivery sheath (DS) reshaped by a heat gun. However, whether the reshaped curve was appropriately adjusted as an optimal configuration for this patient’s anatomy remained uncertain. CASE SUMMARY: We established the LAAC procedural simulation model supported by virtual reality (VR) technology. With this VR simulator, the patient’s whole heart model with venous access route and atrial septal puncture point of foramen ovale (FO) could be replicated based on the pre-procedural computed tomography image. Multiple views of the VR image provided a deep understanding of the patient-specific anatomy. Additionally, the operators were enabled to perform the virtual LAAC procedure using VR-derived LAAC devices, including various DS types. In the VR simulator, the manually reshaped DS showed better co-axiality from the FO to the LAA orifice than the conventional double-curve DS, resulting in the successful deployment inside the LAA of the VR simulator. However, the perpendicularity of the device towards the LAA orifice of the handmade reshaped DS remained insufficient. The VR simulator suggested that the ideal curve of the DS needed to change relatively posteriorly and have a more aggressive inferior slide than the previously reshaped DS. DISCUSSION: The post-procedural review of the VR simulator confirmed that the sheath reshaping technique helped ensure successful LAAC. Pre-procedural VR simulation may be useful for procedural planning that includes DS reshaping for patients with challenging anatomy undergoing LAAC. |
format | Online Article Text |
id | pubmed-10633782 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-106337822023-11-10 Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report Shimura, Tetsuro Higami, Hirooki Matsuo, Hitoshi Yamamoto, Masanori Eur Heart J Case Rep Case Report BACKGROUND: We previously reported a case of successful percutaneous left atrial appendage closure (LAAC) for complex left atrial appendage (LAA) morphology using a handmade double-curve delivery sheath (DS) reshaped by a heat gun. However, whether the reshaped curve was appropriately adjusted as an optimal configuration for this patient’s anatomy remained uncertain. CASE SUMMARY: We established the LAAC procedural simulation model supported by virtual reality (VR) technology. With this VR simulator, the patient’s whole heart model with venous access route and atrial septal puncture point of foramen ovale (FO) could be replicated based on the pre-procedural computed tomography image. Multiple views of the VR image provided a deep understanding of the patient-specific anatomy. Additionally, the operators were enabled to perform the virtual LAAC procedure using VR-derived LAAC devices, including various DS types. In the VR simulator, the manually reshaped DS showed better co-axiality from the FO to the LAA orifice than the conventional double-curve DS, resulting in the successful deployment inside the LAA of the VR simulator. However, the perpendicularity of the device towards the LAA orifice of the handmade reshaped DS remained insufficient. The VR simulator suggested that the ideal curve of the DS needed to change relatively posteriorly and have a more aggressive inferior slide than the previously reshaped DS. DISCUSSION: The post-procedural review of the VR simulator confirmed that the sheath reshaping technique helped ensure successful LAAC. Pre-procedural VR simulation may be useful for procedural planning that includes DS reshaping for patients with challenging anatomy undergoing LAAC. Oxford University Press 2023-10-09 /pmc/articles/PMC10633782/ /pubmed/37954569 http://dx.doi.org/10.1093/ehjcr/ytad503 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Report Shimura, Tetsuro Higami, Hirooki Matsuo, Hitoshi Yamamoto, Masanori Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report |
title | Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report |
title_full | Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report |
title_fullStr | Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report |
title_full_unstemmed | Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report |
title_short | Appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report |
title_sort | appropriate assessment using virtual reality simulation for a novel reshaped curve sheath during percutaneous left atrial appendage closure: a follow-up case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633782/ https://www.ncbi.nlm.nih.gov/pubmed/37954569 http://dx.doi.org/10.1093/ehjcr/ytad503 |
work_keys_str_mv | AT shimuratetsuro appropriateassessmentusingvirtualrealitysimulationforanovelreshapedcurvesheathduringpercutaneousleftatrialappendageclosureafollowupcasereport AT higamihirooki appropriateassessmentusingvirtualrealitysimulationforanovelreshapedcurvesheathduringpercutaneousleftatrialappendageclosureafollowupcasereport AT matsuohitoshi appropriateassessmentusingvirtualrealitysimulationforanovelreshapedcurvesheathduringpercutaneousleftatrialappendageclosureafollowupcasereport AT yamamotomasanori appropriateassessmentusingvirtualrealitysimulationforanovelreshapedcurvesheathduringpercutaneousleftatrialappendageclosureafollowupcasereport |