Cargando…

Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity

Recently, green analytical chemistry (GAC) is a key issue towards the idea of sustainability, the analytical community is focused on developing analytical methods that incorporate green chemistry principles to minimize adverse impacts on the environment and humans. Herein, we present 2 sustainable,...

Descripción completa

Detalles Bibliográficos
Autores principales: Ashour, Esraa S., Hegazy, Maha A., Al-Alamein, Amal M. Abou, El-Sayed, Ghada M., Ghoniem, Nermine S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633899/
https://www.ncbi.nlm.nih.gov/pubmed/37941018
http://dx.doi.org/10.1186/s13065-023-01065-3
_version_ 1785132710905249792
author Ashour, Esraa S.
Hegazy, Maha A.
Al-Alamein, Amal M. Abou
El-Sayed, Ghada M.
Ghoniem, Nermine S.
author_facet Ashour, Esraa S.
Hegazy, Maha A.
Al-Alamein, Amal M. Abou
El-Sayed, Ghada M.
Ghoniem, Nermine S.
author_sort Ashour, Esraa S.
collection PubMed
description Recently, green analytical chemistry (GAC) is a key issue towards the idea of sustainability, the analytical community is focused on developing analytical methods that incorporate green chemistry principles to minimize adverse impacts on the environment and humans. Herein, we present 2 sustainable, selective, and validated chromatographic methods. Initially, lidocaine hydrochloride (LDC) and miconazole nitrate (MIC) with two preservatives; methyl paraben (MTP) and saccharin sodium (SAC) were chromatographed via TLC–densitometric method which employed ethyl acetate: methanol: formic acid (9:1:0.1, by volume) as the mobile phase with UV detection at 220.0 nm, good correlation was obtained in the range of 0.3–3.0 µg/band for MIC and LDC. Following that, RP-HPLC was successfully applied for separating quinary mixture of LDC, MIC, MTP, SAC along with LDC impurity; dimethyl aniline (DMA) using C18 column, and a gradient green mobile phase composed of methanol and phosphate buffer (pH 6.0) in different ratios with a flow rate 1.5 mL/min and UV detection at 210.0 nm, linearity ranges from 1.00 to 100.00 µg/mL for MIC, 2.00–100.00 µg/mL for LDC and 1.00–-20.00 µg/mL for MTP and DMA. No records to date regarding the determination of the two drugs, besides MTP and DMA. The proposed methods were validated according to the ICH guidelines and applied successfully to the analysis of the compounds. The methods' results were statistically compared to those obtained by applying the reported one, indicating no significant difference regarding both accuracy and precision. The methods' greenness profiles have been assessed and compared with those of the reported method using different assessment tools. GRAPHICAL ABSTRACT: [Image: see text]
format Online
Article
Text
id pubmed-10633899
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-106338992023-11-10 Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity Ashour, Esraa S. Hegazy, Maha A. Al-Alamein, Amal M. Abou El-Sayed, Ghada M. Ghoniem, Nermine S. BMC Chem Research Recently, green analytical chemistry (GAC) is a key issue towards the idea of sustainability, the analytical community is focused on developing analytical methods that incorporate green chemistry principles to minimize adverse impacts on the environment and humans. Herein, we present 2 sustainable, selective, and validated chromatographic methods. Initially, lidocaine hydrochloride (LDC) and miconazole nitrate (MIC) with two preservatives; methyl paraben (MTP) and saccharin sodium (SAC) were chromatographed via TLC–densitometric method which employed ethyl acetate: methanol: formic acid (9:1:0.1, by volume) as the mobile phase with UV detection at 220.0 nm, good correlation was obtained in the range of 0.3–3.0 µg/band for MIC and LDC. Following that, RP-HPLC was successfully applied for separating quinary mixture of LDC, MIC, MTP, SAC along with LDC impurity; dimethyl aniline (DMA) using C18 column, and a gradient green mobile phase composed of methanol and phosphate buffer (pH 6.0) in different ratios with a flow rate 1.5 mL/min and UV detection at 210.0 nm, linearity ranges from 1.00 to 100.00 µg/mL for MIC, 2.00–100.00 µg/mL for LDC and 1.00–-20.00 µg/mL for MTP and DMA. No records to date regarding the determination of the two drugs, besides MTP and DMA. The proposed methods were validated according to the ICH guidelines and applied successfully to the analysis of the compounds. The methods' results were statistically compared to those obtained by applying the reported one, indicating no significant difference regarding both accuracy and precision. The methods' greenness profiles have been assessed and compared with those of the reported method using different assessment tools. GRAPHICAL ABSTRACT: [Image: see text] Springer International Publishing 2023-11-08 /pmc/articles/PMC10633899/ /pubmed/37941018 http://dx.doi.org/10.1186/s13065-023-01065-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Ashour, Esraa S.
Hegazy, Maha A.
Al-Alamein, Amal M. Abou
El-Sayed, Ghada M.
Ghoniem, Nermine S.
Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity
title Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity
title_full Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity
title_fullStr Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity
title_full_unstemmed Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity
title_short Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity
title_sort green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633899/
https://www.ncbi.nlm.nih.gov/pubmed/37941018
http://dx.doi.org/10.1186/s13065-023-01065-3
work_keys_str_mv AT ashouresraas greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity
AT hegazymahaa greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity
AT alalameinamalmabou greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity
AT elsayedghadam greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity
AT ghoniemnermines greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity