Cargando…
Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity
Recently, green analytical chemistry (GAC) is a key issue towards the idea of sustainability, the analytical community is focused on developing analytical methods that incorporate green chemistry principles to minimize adverse impacts on the environment and humans. Herein, we present 2 sustainable,...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633899/ https://www.ncbi.nlm.nih.gov/pubmed/37941018 http://dx.doi.org/10.1186/s13065-023-01065-3 |
_version_ | 1785132710905249792 |
---|---|
author | Ashour, Esraa S. Hegazy, Maha A. Al-Alamein, Amal M. Abou El-Sayed, Ghada M. Ghoniem, Nermine S. |
author_facet | Ashour, Esraa S. Hegazy, Maha A. Al-Alamein, Amal M. Abou El-Sayed, Ghada M. Ghoniem, Nermine S. |
author_sort | Ashour, Esraa S. |
collection | PubMed |
description | Recently, green analytical chemistry (GAC) is a key issue towards the idea of sustainability, the analytical community is focused on developing analytical methods that incorporate green chemistry principles to minimize adverse impacts on the environment and humans. Herein, we present 2 sustainable, selective, and validated chromatographic methods. Initially, lidocaine hydrochloride (LDC) and miconazole nitrate (MIC) with two preservatives; methyl paraben (MTP) and saccharin sodium (SAC) were chromatographed via TLC–densitometric method which employed ethyl acetate: methanol: formic acid (9:1:0.1, by volume) as the mobile phase with UV detection at 220.0 nm, good correlation was obtained in the range of 0.3–3.0 µg/band for MIC and LDC. Following that, RP-HPLC was successfully applied for separating quinary mixture of LDC, MIC, MTP, SAC along with LDC impurity; dimethyl aniline (DMA) using C18 column, and a gradient green mobile phase composed of methanol and phosphate buffer (pH 6.0) in different ratios with a flow rate 1.5 mL/min and UV detection at 210.0 nm, linearity ranges from 1.00 to 100.00 µg/mL for MIC, 2.00–100.00 µg/mL for LDC and 1.00–-20.00 µg/mL for MTP and DMA. No records to date regarding the determination of the two drugs, besides MTP and DMA. The proposed methods were validated according to the ICH guidelines and applied successfully to the analysis of the compounds. The methods' results were statistically compared to those obtained by applying the reported one, indicating no significant difference regarding both accuracy and precision. The methods' greenness profiles have been assessed and compared with those of the reported method using different assessment tools. GRAPHICAL ABSTRACT: [Image: see text] |
format | Online Article Text |
id | pubmed-10633899 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-106338992023-11-10 Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity Ashour, Esraa S. Hegazy, Maha A. Al-Alamein, Amal M. Abou El-Sayed, Ghada M. Ghoniem, Nermine S. BMC Chem Research Recently, green analytical chemistry (GAC) is a key issue towards the idea of sustainability, the analytical community is focused on developing analytical methods that incorporate green chemistry principles to minimize adverse impacts on the environment and humans. Herein, we present 2 sustainable, selective, and validated chromatographic methods. Initially, lidocaine hydrochloride (LDC) and miconazole nitrate (MIC) with two preservatives; methyl paraben (MTP) and saccharin sodium (SAC) were chromatographed via TLC–densitometric method which employed ethyl acetate: methanol: formic acid (9:1:0.1, by volume) as the mobile phase with UV detection at 220.0 nm, good correlation was obtained in the range of 0.3–3.0 µg/band for MIC and LDC. Following that, RP-HPLC was successfully applied for separating quinary mixture of LDC, MIC, MTP, SAC along with LDC impurity; dimethyl aniline (DMA) using C18 column, and a gradient green mobile phase composed of methanol and phosphate buffer (pH 6.0) in different ratios with a flow rate 1.5 mL/min and UV detection at 210.0 nm, linearity ranges from 1.00 to 100.00 µg/mL for MIC, 2.00–100.00 µg/mL for LDC and 1.00–-20.00 µg/mL for MTP and DMA. No records to date regarding the determination of the two drugs, besides MTP and DMA. The proposed methods were validated according to the ICH guidelines and applied successfully to the analysis of the compounds. The methods' results were statistically compared to those obtained by applying the reported one, indicating no significant difference regarding both accuracy and precision. The methods' greenness profiles have been assessed and compared with those of the reported method using different assessment tools. GRAPHICAL ABSTRACT: [Image: see text] Springer International Publishing 2023-11-08 /pmc/articles/PMC10633899/ /pubmed/37941018 http://dx.doi.org/10.1186/s13065-023-01065-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Ashour, Esraa S. Hegazy, Maha A. Al-Alamein, Amal M. Abou El-Sayed, Ghada M. Ghoniem, Nermine S. Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity |
title | Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity |
title_full | Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity |
title_fullStr | Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity |
title_full_unstemmed | Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity |
title_short | Green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity |
title_sort | green chromatographic methods for determination of co-formulated lidocaine hydrochloride and miconazole nitrate along with an endocrine disruptor preservative and potential impurity |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633899/ https://www.ncbi.nlm.nih.gov/pubmed/37941018 http://dx.doi.org/10.1186/s13065-023-01065-3 |
work_keys_str_mv | AT ashouresraas greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity AT hegazymahaa greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity AT alalameinamalmabou greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity AT elsayedghadam greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity AT ghoniemnermines greenchromatographicmethodsfordeterminationofcoformulatedlidocainehydrochlorideandmiconazolenitratealongwithanendocrinedisruptorpreservativeandpotentialimpurity |