Cargando…

Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study

BACKGROUND: The accuracy of ultrasound in distinguishing benign from malignant adnexal masses is highly correlated with the experience of ultrasound physicians. In China, most of ultrasound differentiation is done by junior physicians. PURPOSE: To compare the diagnostic performance of the Internatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Tian, Cai, Wen, Shu-Bin, Zhao, Cong-Ying, Yan, Xiao-Nan, Du, Jie-Xian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633950/
https://www.ncbi.nlm.nih.gov/pubmed/37940895
http://dx.doi.org/10.1186/s12905-023-02719-z
_version_ 1785132723154714624
author Tian, Cai
Wen, Shu-Bin
Zhao, Cong-Ying
Yan, Xiao-Nan
Du, Jie-Xian
author_facet Tian, Cai
Wen, Shu-Bin
Zhao, Cong-Ying
Yan, Xiao-Nan
Du, Jie-Xian
author_sort Tian, Cai
collection PubMed
description BACKGROUND: The accuracy of ultrasound in distinguishing benign from malignant adnexal masses is highly correlated with the experience of ultrasound physicians. In China, most of ultrasound differentiation is done by junior physicians. PURPOSE: To compare the diagnostic performance of the International Ovarian Tumour Analysis (IOTA) Simple Rules Risk (SRR) and IOTA Logistic Regression Model 2 (LR2) scoring systems in Chinese patients with adnexal masses. METHODS: Retrospective analysis of ovarian cancer tumor patients who underwent surgery at a hospital in China from January 2016 to December 2021. Screening patients with at least one adnexal mass on inclusion and exclusion criteria. Two trained junior physicians evaluated each mass using the two scoring systems. A receiver operating characteristic curve was used to test the diagnostic performance of each system. RESULTS: A total of 144 adnexal masses were retrospectively collected. Forty masses were histologically diagnosed as malignant. Compared with premenopausal women, postmenopausal women had a much higher rate of malignant masses. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of the SRR was 97.5% (95% CI: 86.8 -99.9%), 82.7% (95% CI: 74.0 -89.4%), 68.4% (95% CI: 58.7 -76.8%) and 98.9% (95% CI: 92.5 -99.8%). The sensitivity, specificity, PPV, NPV of the LR2 were 90.0% (95% CI: 76.5 -97.2%), 89.4% (95% CI: 81.9 -94.6%), 76.6% (95% CI: 65.0 -85.2%), and 95.9% (95% CI: 90.2 -98.3%). There was good agreement between two scoring systems, with 84.03% total agreement and a kappa value of 0.783 (95% CI: 0.70-0.864). The areas under the curve for predicting malignant tumours using SRR and LR2 were similar for all patients (P > 0.05 ). CONCLUSION: The two scoring systems can effectively distinguish benign from malignant adnexal masses. Both scoring systems have high diagnostic efficacy, and diagnostic efficacy is stable, which can provide an important reference for clinical decision making.
format Online
Article
Text
id pubmed-10633950
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-106339502023-11-10 Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study Tian, Cai Wen, Shu-Bin Zhao, Cong-Ying Yan, Xiao-Nan Du, Jie-Xian BMC Womens Health Research BACKGROUND: The accuracy of ultrasound in distinguishing benign from malignant adnexal masses is highly correlated with the experience of ultrasound physicians. In China, most of ultrasound differentiation is done by junior physicians. PURPOSE: To compare the diagnostic performance of the International Ovarian Tumour Analysis (IOTA) Simple Rules Risk (SRR) and IOTA Logistic Regression Model 2 (LR2) scoring systems in Chinese patients with adnexal masses. METHODS: Retrospective analysis of ovarian cancer tumor patients who underwent surgery at a hospital in China from January 2016 to December 2021. Screening patients with at least one adnexal mass on inclusion and exclusion criteria. Two trained junior physicians evaluated each mass using the two scoring systems. A receiver operating characteristic curve was used to test the diagnostic performance of each system. RESULTS: A total of 144 adnexal masses were retrospectively collected. Forty masses were histologically diagnosed as malignant. Compared with premenopausal women, postmenopausal women had a much higher rate of malignant masses. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of the SRR was 97.5% (95% CI: 86.8 -99.9%), 82.7% (95% CI: 74.0 -89.4%), 68.4% (95% CI: 58.7 -76.8%) and 98.9% (95% CI: 92.5 -99.8%). The sensitivity, specificity, PPV, NPV of the LR2 were 90.0% (95% CI: 76.5 -97.2%), 89.4% (95% CI: 81.9 -94.6%), 76.6% (95% CI: 65.0 -85.2%), and 95.9% (95% CI: 90.2 -98.3%). There was good agreement between two scoring systems, with 84.03% total agreement and a kappa value of 0.783 (95% CI: 0.70-0.864). The areas under the curve for predicting malignant tumours using SRR and LR2 were similar for all patients (P > 0.05 ). CONCLUSION: The two scoring systems can effectively distinguish benign from malignant adnexal masses. Both scoring systems have high diagnostic efficacy, and diagnostic efficacy is stable, which can provide an important reference for clinical decision making. BioMed Central 2023-11-08 /pmc/articles/PMC10633950/ /pubmed/37940895 http://dx.doi.org/10.1186/s12905-023-02719-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Tian, Cai
Wen, Shu-Bin
Zhao, Cong-Ying
Yan, Xiao-Nan
Du, Jie-Xian
Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study
title Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study
title_full Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study
title_fullStr Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study
title_full_unstemmed Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study
title_short Comparative diagnostic accuracy of the IOTA SRR and LR2 scoring systems for discriminating between malignant and Benign Adnexal masses by junior physicians in Chinese patients: a retrospective observational study
title_sort comparative diagnostic accuracy of the iota srr and lr2 scoring systems for discriminating between malignant and benign adnexal masses by junior physicians in chinese patients: a retrospective observational study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633950/
https://www.ncbi.nlm.nih.gov/pubmed/37940895
http://dx.doi.org/10.1186/s12905-023-02719-z
work_keys_str_mv AT tiancai comparativediagnosticaccuracyoftheiotasrrandlr2scoringsystemsfordiscriminatingbetweenmalignantandbenignadnexalmassesbyjuniorphysiciansinchinesepatientsaretrospectiveobservationalstudy
AT wenshubin comparativediagnosticaccuracyoftheiotasrrandlr2scoringsystemsfordiscriminatingbetweenmalignantandbenignadnexalmassesbyjuniorphysiciansinchinesepatientsaretrospectiveobservationalstudy
AT zhaocongying comparativediagnosticaccuracyoftheiotasrrandlr2scoringsystemsfordiscriminatingbetweenmalignantandbenignadnexalmassesbyjuniorphysiciansinchinesepatientsaretrospectiveobservationalstudy
AT yanxiaonan comparativediagnosticaccuracyoftheiotasrrandlr2scoringsystemsfordiscriminatingbetweenmalignantandbenignadnexalmassesbyjuniorphysiciansinchinesepatientsaretrospectiveobservationalstudy
AT dujiexian comparativediagnosticaccuracyoftheiotasrrandlr2scoringsystemsfordiscriminatingbetweenmalignantandbenignadnexalmassesbyjuniorphysiciansinchinesepatientsaretrospectiveobservationalstudy