Cargando…

Donor/recipient ascending aortic diameter ratio as a novel potential metric for donor selection and improved clinical outcomes in heart transplantation: a propensity score-matched study

BACKGROUND: Donor/recipient size matching is paramount in heart transplantation. Body weight, height, body mass index, body surface area, and predicted heart mass (PHM) ratios are generally used in size matching. Precise size matching is important to achieve better clinical outcomes. This study aims...

Descripción completa

Detalles Bibliográficos
Autores principales: Masroor, Matiullah, Chen, Yuqi, Wang, Yixuan, Dong, Nianguo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10634287/
https://www.ncbi.nlm.nih.gov/pubmed/37953761
http://dx.doi.org/10.3389/fcvm.2023.1277825
_version_ 1785132799707054080
author Masroor, Matiullah
Chen, Yuqi
Wang, Yixuan
Dong, Nianguo
author_facet Masroor, Matiullah
Chen, Yuqi
Wang, Yixuan
Dong, Nianguo
author_sort Masroor, Matiullah
collection PubMed
description BACKGROUND: Donor/recipient size matching is paramount in heart transplantation. Body weight, height, body mass index, body surface area, and predicted heart mass (PHM) ratios are generally used in size matching. Precise size matching is important to achieve better clinical outcomes. This study aims to determine the donor/recipient ascending aortic diameter (AAoD) ratio as a metric for donor selection and its effect on postoperative clinical outcomes in heart transplant patients. METHODS: We retrospectively reviewed all consecutive patients who underwent heart transplantation from January 2015 to December 2018. A cutoff value of 0.8032 for the donor/recipient AAoD ratio (independent variable for the primary endpoint during unmatched cohort analysis) was determined for predicting in-hospital mortality. The patients were divided into two groups based on the cutoff value. Group A, AAoD < 0.8032 (n = 96), and Group B, AAoD > 0.8032 (n = 265). A propensity score-matched (PSM) study was performed to equalize the two groups comprising 77 patients each in terms of risk. A Cox regression model was developed to identify the independent preoperative variables affecting the primary end-point. The primary endpoint was all-cause in-hospital mortality. RESULTS: A total of 361 patients underwent heart transplantation during the given period. On the multivariate analysis, donor/recipient PHM ratio [HR 16.907, 95% confidence interval (CI) 1.535–186.246, P = 0.021], donor/recipient AAoD ratio < 0.8032 (HR 5.398, 95% CI 1.181–24.681, P = 0.030), and diabetes (HR 3.138, 95% CI 1.017–9.689, P = 0.047) were found to be independent predictors of in-hospital mortality. Group A had higher 3-year mortality than Group B (P = 0.022). The surgery time was longer and postoperative RBC, plasma, and platelets transfusion were higher in Group A (P < 0.05). Although not statistically significant the use of continuous renal replacement therapy (P = 0.054), and extracorporeal membrane oxygenation (P = 0.086), was realatively higher, and ventilation time (P = 0.079) was relatively longer in Group A. CONCLUSIONS: The donor/recipient AAoD ratio is a potential metric for patient matching and postoperative outcomes in heart transplantation. A donor/recipient AAoD ratio > 0.8032 could improve post-heart transplantation outcomes and donor heart utilization.
format Online
Article
Text
id pubmed-10634287
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-106342872023-11-10 Donor/recipient ascending aortic diameter ratio as a novel potential metric for donor selection and improved clinical outcomes in heart transplantation: a propensity score-matched study Masroor, Matiullah Chen, Yuqi Wang, Yixuan Dong, Nianguo Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: Donor/recipient size matching is paramount in heart transplantation. Body weight, height, body mass index, body surface area, and predicted heart mass (PHM) ratios are generally used in size matching. Precise size matching is important to achieve better clinical outcomes. This study aims to determine the donor/recipient ascending aortic diameter (AAoD) ratio as a metric for donor selection and its effect on postoperative clinical outcomes in heart transplant patients. METHODS: We retrospectively reviewed all consecutive patients who underwent heart transplantation from January 2015 to December 2018. A cutoff value of 0.8032 for the donor/recipient AAoD ratio (independent variable for the primary endpoint during unmatched cohort analysis) was determined for predicting in-hospital mortality. The patients were divided into two groups based on the cutoff value. Group A, AAoD < 0.8032 (n = 96), and Group B, AAoD > 0.8032 (n = 265). A propensity score-matched (PSM) study was performed to equalize the two groups comprising 77 patients each in terms of risk. A Cox regression model was developed to identify the independent preoperative variables affecting the primary end-point. The primary endpoint was all-cause in-hospital mortality. RESULTS: A total of 361 patients underwent heart transplantation during the given period. On the multivariate analysis, donor/recipient PHM ratio [HR 16.907, 95% confidence interval (CI) 1.535–186.246, P = 0.021], donor/recipient AAoD ratio < 0.8032 (HR 5.398, 95% CI 1.181–24.681, P = 0.030), and diabetes (HR 3.138, 95% CI 1.017–9.689, P = 0.047) were found to be independent predictors of in-hospital mortality. Group A had higher 3-year mortality than Group B (P = 0.022). The surgery time was longer and postoperative RBC, plasma, and platelets transfusion were higher in Group A (P < 0.05). Although not statistically significant the use of continuous renal replacement therapy (P = 0.054), and extracorporeal membrane oxygenation (P = 0.086), was realatively higher, and ventilation time (P = 0.079) was relatively longer in Group A. CONCLUSIONS: The donor/recipient AAoD ratio is a potential metric for patient matching and postoperative outcomes in heart transplantation. A donor/recipient AAoD ratio > 0.8032 could improve post-heart transplantation outcomes and donor heart utilization. Frontiers Media S.A. 2023-10-25 /pmc/articles/PMC10634287/ /pubmed/37953761 http://dx.doi.org/10.3389/fcvm.2023.1277825 Text en © 2023 Masroor, Chen, Wang and Dong. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Masroor, Matiullah
Chen, Yuqi
Wang, Yixuan
Dong, Nianguo
Donor/recipient ascending aortic diameter ratio as a novel potential metric for donor selection and improved clinical outcomes in heart transplantation: a propensity score-matched study
title Donor/recipient ascending aortic diameter ratio as a novel potential metric for donor selection and improved clinical outcomes in heart transplantation: a propensity score-matched study
title_full Donor/recipient ascending aortic diameter ratio as a novel potential metric for donor selection and improved clinical outcomes in heart transplantation: a propensity score-matched study
title_fullStr Donor/recipient ascending aortic diameter ratio as a novel potential metric for donor selection and improved clinical outcomes in heart transplantation: a propensity score-matched study
title_full_unstemmed Donor/recipient ascending aortic diameter ratio as a novel potential metric for donor selection and improved clinical outcomes in heart transplantation: a propensity score-matched study
title_short Donor/recipient ascending aortic diameter ratio as a novel potential metric for donor selection and improved clinical outcomes in heart transplantation: a propensity score-matched study
title_sort donor/recipient ascending aortic diameter ratio as a novel potential metric for donor selection and improved clinical outcomes in heart transplantation: a propensity score-matched study
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10634287/
https://www.ncbi.nlm.nih.gov/pubmed/37953761
http://dx.doi.org/10.3389/fcvm.2023.1277825
work_keys_str_mv AT masroormatiullah donorrecipientascendingaorticdiameterratioasanovelpotentialmetricfordonorselectionandimprovedclinicaloutcomesinhearttransplantationapropensityscorematchedstudy
AT chenyuqi donorrecipientascendingaorticdiameterratioasanovelpotentialmetricfordonorselectionandimprovedclinicaloutcomesinhearttransplantationapropensityscorematchedstudy
AT wangyixuan donorrecipientascendingaorticdiameterratioasanovelpotentialmetricfordonorselectionandimprovedclinicaloutcomesinhearttransplantationapropensityscorematchedstudy
AT dongnianguo donorrecipientascendingaorticdiameterratioasanovelpotentialmetricfordonorselectionandimprovedclinicaloutcomesinhearttransplantationapropensityscorematchedstudy