Cargando…

Comparison of three fluids for calibration of the new Periotron® 8010

BACKGROUND: The aim of the present study was to calibrate the Periotron® model 8010 with volumes of three different fluids (distilled water, serum, and saliva) and to identify which of the three is the most reliable, feasible, and reproducible for routine calibration. MATERIAL AND METHODS: A total o...

Descripción completa

Detalles Bibliográficos
Autores principales: Fernández-Reyes, Meylin, Márquez-Arrico, Cecilia Fabiana, Silvestre, Francisco Javier, Perea-Galera, Laura, Silvestre-Rangil, Javier, Rocha, Milagros
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635629/
https://www.ncbi.nlm.nih.gov/pubmed/37099707
http://dx.doi.org/10.4317/medoral.25917
_version_ 1785146345991962624
author Fernández-Reyes, Meylin
Márquez-Arrico, Cecilia Fabiana
Silvestre, Francisco Javier
Perea-Galera, Laura
Silvestre-Rangil, Javier
Rocha, Milagros
author_facet Fernández-Reyes, Meylin
Márquez-Arrico, Cecilia Fabiana
Silvestre, Francisco Javier
Perea-Galera, Laura
Silvestre-Rangil, Javier
Rocha, Milagros
author_sort Fernández-Reyes, Meylin
collection PubMed
description BACKGROUND: The aim of the present study was to calibrate the Periotron® model 8010 with volumes of three different fluids (distilled water, serum, and saliva) and to identify which of the three is the most reliable, feasible, and reproducible for routine calibration. MATERIAL AND METHODS: A total of 450 samples of Periopaper® were divided into three groups (150 each per group): distilled water, serum matrix and saliva. A calibration curve was run with 0.25, 0.50, 0.75, 1.00 and 1.25 µl of each of the fluids, and the results were determined in Periotron units (PU). Statistical analysis was performed with one-way ANOVA followed by Bonferroni’s post hoc test and a linear equation. RESULTS: Distilled water presented the lowest levels of PU at all volumes, while serum showed the highest levels at high volumes. Linear regression equations rendered similar slopes for saliva and distilled water, while serum was statistically different. Saliva presented a reproduction percentage of 99.7%, which indicated better accuracy and precision than serum and distilled water. CONCLUSIONS: Saliva is more reliable and accurate than water or serum for the purpose of calibration of the Periotron® model 8010, though it shares drawbacks with serum. Distilled water is more easily available and does not require any additional procedure, in addition to producing a similar slope to saliva and a smaller deviation from the media than serum. Key words:Gingival crevicular fluid, periodontics, calibration, periodontal disease.
format Online
Article
Text
id pubmed-10635629
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-106356292023-11-15 Comparison of three fluids for calibration of the new Periotron® 8010 Fernández-Reyes, Meylin Márquez-Arrico, Cecilia Fabiana Silvestre, Francisco Javier Perea-Galera, Laura Silvestre-Rangil, Javier Rocha, Milagros Med Oral Patol Oral Cir Bucal Research BACKGROUND: The aim of the present study was to calibrate the Periotron® model 8010 with volumes of three different fluids (distilled water, serum, and saliva) and to identify which of the three is the most reliable, feasible, and reproducible for routine calibration. MATERIAL AND METHODS: A total of 450 samples of Periopaper® were divided into three groups (150 each per group): distilled water, serum matrix and saliva. A calibration curve was run with 0.25, 0.50, 0.75, 1.00 and 1.25 µl of each of the fluids, and the results were determined in Periotron units (PU). Statistical analysis was performed with one-way ANOVA followed by Bonferroni’s post hoc test and a linear equation. RESULTS: Distilled water presented the lowest levels of PU at all volumes, while serum showed the highest levels at high volumes. Linear regression equations rendered similar slopes for saliva and distilled water, while serum was statistically different. Saliva presented a reproduction percentage of 99.7%, which indicated better accuracy and precision than serum and distilled water. CONCLUSIONS: Saliva is more reliable and accurate than water or serum for the purpose of calibration of the Periotron® model 8010, though it shares drawbacks with serum. Distilled water is more easily available and does not require any additional procedure, in addition to producing a similar slope to saliva and a smaller deviation from the media than serum. Key words:Gingival crevicular fluid, periodontics, calibration, periodontal disease. Medicina Oral S.L. 2023-11 2023-04-26 /pmc/articles/PMC10635629/ /pubmed/37099707 http://dx.doi.org/10.4317/medoral.25917 Text en Copyright: © 2023 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Fernández-Reyes, Meylin
Márquez-Arrico, Cecilia Fabiana
Silvestre, Francisco Javier
Perea-Galera, Laura
Silvestre-Rangil, Javier
Rocha, Milagros
Comparison of three fluids for calibration of the new Periotron® 8010
title Comparison of three fluids for calibration of the new Periotron® 8010
title_full Comparison of three fluids for calibration of the new Periotron® 8010
title_fullStr Comparison of three fluids for calibration of the new Periotron® 8010
title_full_unstemmed Comparison of three fluids for calibration of the new Periotron® 8010
title_short Comparison of three fluids for calibration of the new Periotron® 8010
title_sort comparison of three fluids for calibration of the new periotron® 8010
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635629/
https://www.ncbi.nlm.nih.gov/pubmed/37099707
http://dx.doi.org/10.4317/medoral.25917
work_keys_str_mv AT fernandezreyesmeylin comparisonofthreefluidsforcalibrationofthenewperiotron8010
AT marquezarricoceciliafabiana comparisonofthreefluidsforcalibrationofthenewperiotron8010
AT silvestrefranciscojavier comparisonofthreefluidsforcalibrationofthenewperiotron8010
AT pereagaleralaura comparisonofthreefluidsforcalibrationofthenewperiotron8010
AT silvestrerangiljavier comparisonofthreefluidsforcalibrationofthenewperiotron8010
AT rochamilagros comparisonofthreefluidsforcalibrationofthenewperiotron8010