Cargando…
Comparison of three fluids for calibration of the new Periotron® 8010
BACKGROUND: The aim of the present study was to calibrate the Periotron® model 8010 with volumes of three different fluids (distilled water, serum, and saliva) and to identify which of the three is the most reliable, feasible, and reproducible for routine calibration. MATERIAL AND METHODS: A total o...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635629/ https://www.ncbi.nlm.nih.gov/pubmed/37099707 http://dx.doi.org/10.4317/medoral.25917 |
_version_ | 1785146345991962624 |
---|---|
author | Fernández-Reyes, Meylin Márquez-Arrico, Cecilia Fabiana Silvestre, Francisco Javier Perea-Galera, Laura Silvestre-Rangil, Javier Rocha, Milagros |
author_facet | Fernández-Reyes, Meylin Márquez-Arrico, Cecilia Fabiana Silvestre, Francisco Javier Perea-Galera, Laura Silvestre-Rangil, Javier Rocha, Milagros |
author_sort | Fernández-Reyes, Meylin |
collection | PubMed |
description | BACKGROUND: The aim of the present study was to calibrate the Periotron® model 8010 with volumes of three different fluids (distilled water, serum, and saliva) and to identify which of the three is the most reliable, feasible, and reproducible for routine calibration. MATERIAL AND METHODS: A total of 450 samples of Periopaper® were divided into three groups (150 each per group): distilled water, serum matrix and saliva. A calibration curve was run with 0.25, 0.50, 0.75, 1.00 and 1.25 µl of each of the fluids, and the results were determined in Periotron units (PU). Statistical analysis was performed with one-way ANOVA followed by Bonferroni’s post hoc test and a linear equation. RESULTS: Distilled water presented the lowest levels of PU at all volumes, while serum showed the highest levels at high volumes. Linear regression equations rendered similar slopes for saliva and distilled water, while serum was statistically different. Saliva presented a reproduction percentage of 99.7%, which indicated better accuracy and precision than serum and distilled water. CONCLUSIONS: Saliva is more reliable and accurate than water or serum for the purpose of calibration of the Periotron® model 8010, though it shares drawbacks with serum. Distilled water is more easily available and does not require any additional procedure, in addition to producing a similar slope to saliva and a smaller deviation from the media than serum. Key words:Gingival crevicular fluid, periodontics, calibration, periodontal disease. |
format | Online Article Text |
id | pubmed-10635629 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-106356292023-11-15 Comparison of three fluids for calibration of the new Periotron® 8010 Fernández-Reyes, Meylin Márquez-Arrico, Cecilia Fabiana Silvestre, Francisco Javier Perea-Galera, Laura Silvestre-Rangil, Javier Rocha, Milagros Med Oral Patol Oral Cir Bucal Research BACKGROUND: The aim of the present study was to calibrate the Periotron® model 8010 with volumes of three different fluids (distilled water, serum, and saliva) and to identify which of the three is the most reliable, feasible, and reproducible for routine calibration. MATERIAL AND METHODS: A total of 450 samples of Periopaper® were divided into three groups (150 each per group): distilled water, serum matrix and saliva. A calibration curve was run with 0.25, 0.50, 0.75, 1.00 and 1.25 µl of each of the fluids, and the results were determined in Periotron units (PU). Statistical analysis was performed with one-way ANOVA followed by Bonferroni’s post hoc test and a linear equation. RESULTS: Distilled water presented the lowest levels of PU at all volumes, while serum showed the highest levels at high volumes. Linear regression equations rendered similar slopes for saliva and distilled water, while serum was statistically different. Saliva presented a reproduction percentage of 99.7%, which indicated better accuracy and precision than serum and distilled water. CONCLUSIONS: Saliva is more reliable and accurate than water or serum for the purpose of calibration of the Periotron® model 8010, though it shares drawbacks with serum. Distilled water is more easily available and does not require any additional procedure, in addition to producing a similar slope to saliva and a smaller deviation from the media than serum. Key words:Gingival crevicular fluid, periodontics, calibration, periodontal disease. Medicina Oral S.L. 2023-11 2023-04-26 /pmc/articles/PMC10635629/ /pubmed/37099707 http://dx.doi.org/10.4317/medoral.25917 Text en Copyright: © 2023 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Fernández-Reyes, Meylin Márquez-Arrico, Cecilia Fabiana Silvestre, Francisco Javier Perea-Galera, Laura Silvestre-Rangil, Javier Rocha, Milagros Comparison of three fluids for calibration of the new Periotron® 8010 |
title | Comparison of three fluids for calibration of the new Periotron® 8010 |
title_full | Comparison of three fluids for calibration of the new Periotron® 8010 |
title_fullStr | Comparison of three fluids for calibration of the new Periotron® 8010 |
title_full_unstemmed | Comparison of three fluids for calibration of the new Periotron® 8010 |
title_short | Comparison of three fluids for calibration of the new Periotron® 8010 |
title_sort | comparison of three fluids for calibration of the new periotron® 8010 |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635629/ https://www.ncbi.nlm.nih.gov/pubmed/37099707 http://dx.doi.org/10.4317/medoral.25917 |
work_keys_str_mv | AT fernandezreyesmeylin comparisonofthreefluidsforcalibrationofthenewperiotron8010 AT marquezarricoceciliafabiana comparisonofthreefluidsforcalibrationofthenewperiotron8010 AT silvestrefranciscojavier comparisonofthreefluidsforcalibrationofthenewperiotron8010 AT pereagaleralaura comparisonofthreefluidsforcalibrationofthenewperiotron8010 AT silvestrerangiljavier comparisonofthreefluidsforcalibrationofthenewperiotron8010 AT rochamilagros comparisonofthreefluidsforcalibrationofthenewperiotron8010 |