Cargando…

Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions

BACKGROUND: Device-based antegrade dissection re-entry (ADR) and parallel wire technique (PWT) are two important techniques in the antegrade approach in percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). The study is aimed to compare the procedural and mid-term outcomes betwe...

Descripción completa

Detalles Bibliográficos
Autores principales: Qin, Qing, Chang, Shufu, Xu, Rende, Ge, Lei, Qian, Juying, Ma, Jianying, Ge, Junbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635727/
https://www.ncbi.nlm.nih.gov/pubmed/35244198
http://dx.doi.org/10.5603/CJ.a2022.0008
_version_ 1785146354676269056
author Qin, Qing
Chang, Shufu
Xu, Rende
Ge, Lei
Qian, Juying
Ma, Jianying
Ge, Junbo
author_facet Qin, Qing
Chang, Shufu
Xu, Rende
Ge, Lei
Qian, Juying
Ma, Jianying
Ge, Junbo
author_sort Qin, Qing
collection PubMed
description BACKGROUND: Device-based antegrade dissection re-entry (ADR) and parallel wire technique (PWT) are two important techniques in the antegrade approach in percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). The study is aimed to compare the procedural and mid-term outcomes between device-based ADR using the CrossBoss/Stingray system and PWT in CTO PCI. METHODS: Data was retrospectively collected from consecutive patients who underwent CTO PCI using device-based ADR or PWT. CTO due to in-stent restenosis were excluded. RESULTS: A total of 273 patients were included in the study (n = 55 in device-based ADR group, n = 218 in PWT group). Baseline characteristics were similar across groups except for higher prevalence of prior PCI and lower level of lipid profile in the ADR group. Moreover, although patients in the ADR group showed higher contrast volume (441.6 ± 162.4 mL vs. 361.5 ± 142.1 mL, p < 0.001), more intravascular ultrasound guidance (50.9% vs. 22.9%, p < 0.001), more guidewires used (4.6 ± 1.4 vs. 3.4 ± 1.2, p < 0.001) and higher troponin T level after PCI (0.167 vs. 0.087, p = 0.004), the technical success, procedural success and in-hospital complications were similar between the two groups. During a median follow-up of 1 year, the ADR group showed no difference in major adverse cardiac events (MACE, including all cause death, nonfatal myocardial infarction, and ischemia driven target vessel revascularization) (7.3% vs. 14.7%, p = 0.150) as compared with the PWT group. CONCLUSIONS: In the documented center, the use of device-based ADR for CTO PCI showed no difference in in-hospital complications and mid-term MACE as compared with PWT, despite higher procedure complexity in ADR group.
format Online
Article
Text
id pubmed-10635727
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-106357272023-11-15 Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions Qin, Qing Chang, Shufu Xu, Rende Ge, Lei Qian, Juying Ma, Jianying Ge, Junbo Cardiol J Interventional Cardiology BACKGROUND: Device-based antegrade dissection re-entry (ADR) and parallel wire technique (PWT) are two important techniques in the antegrade approach in percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). The study is aimed to compare the procedural and mid-term outcomes between device-based ADR using the CrossBoss/Stingray system and PWT in CTO PCI. METHODS: Data was retrospectively collected from consecutive patients who underwent CTO PCI using device-based ADR or PWT. CTO due to in-stent restenosis were excluded. RESULTS: A total of 273 patients were included in the study (n = 55 in device-based ADR group, n = 218 in PWT group). Baseline characteristics were similar across groups except for higher prevalence of prior PCI and lower level of lipid profile in the ADR group. Moreover, although patients in the ADR group showed higher contrast volume (441.6 ± 162.4 mL vs. 361.5 ± 142.1 mL, p < 0.001), more intravascular ultrasound guidance (50.9% vs. 22.9%, p < 0.001), more guidewires used (4.6 ± 1.4 vs. 3.4 ± 1.2, p < 0.001) and higher troponin T level after PCI (0.167 vs. 0.087, p = 0.004), the technical success, procedural success and in-hospital complications were similar between the two groups. During a median follow-up of 1 year, the ADR group showed no difference in major adverse cardiac events (MACE, including all cause death, nonfatal myocardial infarction, and ischemia driven target vessel revascularization) (7.3% vs. 14.7%, p = 0.150) as compared with the PWT group. CONCLUSIONS: In the documented center, the use of device-based ADR for CTO PCI showed no difference in in-hospital complications and mid-term MACE as compared with PWT, despite higher procedure complexity in ADR group. Via Medica 2023-10-27 /pmc/articles/PMC10635727/ /pubmed/35244198 http://dx.doi.org/10.5603/CJ.a2022.0008 Text en Copyright © 2023 Via Medica https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially
spellingShingle Interventional Cardiology
Qin, Qing
Chang, Shufu
Xu, Rende
Ge, Lei
Qian, Juying
Ma, Jianying
Ge, Junbo
Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions
title Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions
title_full Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions
title_fullStr Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions
title_full_unstemmed Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions
title_short Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions
title_sort device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions
topic Interventional Cardiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635727/
https://www.ncbi.nlm.nih.gov/pubmed/35244198
http://dx.doi.org/10.5603/CJ.a2022.0008
work_keys_str_mv AT qinqing devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions
AT changshufu devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions
AT xurende devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions
AT gelei devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions
AT qianjuying devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions
AT majianying devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions
AT gejunbo devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions