Cargando…
Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions
BACKGROUND: Device-based antegrade dissection re-entry (ADR) and parallel wire technique (PWT) are two important techniques in the antegrade approach in percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). The study is aimed to compare the procedural and mid-term outcomes betwe...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Via Medica
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635727/ https://www.ncbi.nlm.nih.gov/pubmed/35244198 http://dx.doi.org/10.5603/CJ.a2022.0008 |
_version_ | 1785146354676269056 |
---|---|
author | Qin, Qing Chang, Shufu Xu, Rende Ge, Lei Qian, Juying Ma, Jianying Ge, Junbo |
author_facet | Qin, Qing Chang, Shufu Xu, Rende Ge, Lei Qian, Juying Ma, Jianying Ge, Junbo |
author_sort | Qin, Qing |
collection | PubMed |
description | BACKGROUND: Device-based antegrade dissection re-entry (ADR) and parallel wire technique (PWT) are two important techniques in the antegrade approach in percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). The study is aimed to compare the procedural and mid-term outcomes between device-based ADR using the CrossBoss/Stingray system and PWT in CTO PCI. METHODS: Data was retrospectively collected from consecutive patients who underwent CTO PCI using device-based ADR or PWT. CTO due to in-stent restenosis were excluded. RESULTS: A total of 273 patients were included in the study (n = 55 in device-based ADR group, n = 218 in PWT group). Baseline characteristics were similar across groups except for higher prevalence of prior PCI and lower level of lipid profile in the ADR group. Moreover, although patients in the ADR group showed higher contrast volume (441.6 ± 162.4 mL vs. 361.5 ± 142.1 mL, p < 0.001), more intravascular ultrasound guidance (50.9% vs. 22.9%, p < 0.001), more guidewires used (4.6 ± 1.4 vs. 3.4 ± 1.2, p < 0.001) and higher troponin T level after PCI (0.167 vs. 0.087, p = 0.004), the technical success, procedural success and in-hospital complications were similar between the two groups. During a median follow-up of 1 year, the ADR group showed no difference in major adverse cardiac events (MACE, including all cause death, nonfatal myocardial infarction, and ischemia driven target vessel revascularization) (7.3% vs. 14.7%, p = 0.150) as compared with the PWT group. CONCLUSIONS: In the documented center, the use of device-based ADR for CTO PCI showed no difference in in-hospital complications and mid-term MACE as compared with PWT, despite higher procedure complexity in ADR group. |
format | Online Article Text |
id | pubmed-10635727 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Via Medica |
record_format | MEDLINE/PubMed |
spelling | pubmed-106357272023-11-15 Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions Qin, Qing Chang, Shufu Xu, Rende Ge, Lei Qian, Juying Ma, Jianying Ge, Junbo Cardiol J Interventional Cardiology BACKGROUND: Device-based antegrade dissection re-entry (ADR) and parallel wire technique (PWT) are two important techniques in the antegrade approach in percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). The study is aimed to compare the procedural and mid-term outcomes between device-based ADR using the CrossBoss/Stingray system and PWT in CTO PCI. METHODS: Data was retrospectively collected from consecutive patients who underwent CTO PCI using device-based ADR or PWT. CTO due to in-stent restenosis were excluded. RESULTS: A total of 273 patients were included in the study (n = 55 in device-based ADR group, n = 218 in PWT group). Baseline characteristics were similar across groups except for higher prevalence of prior PCI and lower level of lipid profile in the ADR group. Moreover, although patients in the ADR group showed higher contrast volume (441.6 ± 162.4 mL vs. 361.5 ± 142.1 mL, p < 0.001), more intravascular ultrasound guidance (50.9% vs. 22.9%, p < 0.001), more guidewires used (4.6 ± 1.4 vs. 3.4 ± 1.2, p < 0.001) and higher troponin T level after PCI (0.167 vs. 0.087, p = 0.004), the technical success, procedural success and in-hospital complications were similar between the two groups. During a median follow-up of 1 year, the ADR group showed no difference in major adverse cardiac events (MACE, including all cause death, nonfatal myocardial infarction, and ischemia driven target vessel revascularization) (7.3% vs. 14.7%, p = 0.150) as compared with the PWT group. CONCLUSIONS: In the documented center, the use of device-based ADR for CTO PCI showed no difference in in-hospital complications and mid-term MACE as compared with PWT, despite higher procedure complexity in ADR group. Via Medica 2023-10-27 /pmc/articles/PMC10635727/ /pubmed/35244198 http://dx.doi.org/10.5603/CJ.a2022.0008 Text en Copyright © 2023 Via Medica https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially |
spellingShingle | Interventional Cardiology Qin, Qing Chang, Shufu Xu, Rende Ge, Lei Qian, Juying Ma, Jianying Ge, Junbo Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions |
title | Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions |
title_full | Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions |
title_fullStr | Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions |
title_full_unstemmed | Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions |
title_short | Device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions |
title_sort | device-based antegrade dissection re-entry versus parallel wire techniques for the percutaneous revascularization of coronary chronic total occlusions |
topic | Interventional Cardiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635727/ https://www.ncbi.nlm.nih.gov/pubmed/35244198 http://dx.doi.org/10.5603/CJ.a2022.0008 |
work_keys_str_mv | AT qinqing devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions AT changshufu devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions AT xurende devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions AT gelei devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions AT qianjuying devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions AT majianying devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions AT gejunbo devicebasedantegradedissectionreentryversusparallelwiretechniquesforthepercutaneousrevascularizationofcoronarychronictotalocclusions |