Cargando…

A comparison of tracheal intubation using intubrite laryngoscope and conventional MAC laryngoscope: An open, prospective, crossover manikin study

BACKGROUND: New devices are more available in the pre-hospital environment operational theaters and emergency departments. One is an intubrite laryngoscope (INT) with Dual LED lighting that combines ultraviolet and white LED. The study aimed to compare the efficacy of endotracheal intubation using I...

Descripción completa

Detalles Bibliográficos
Autores principales: Ratajczyk, Pawel, Fedorczak, Michal, Kluj, Przemyslaw, Gaszynski, Tomasz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10637480/
https://www.ncbi.nlm.nih.gov/pubmed/37960794
http://dx.doi.org/10.1097/MD.0000000000035846
_version_ 1785146507180113920
author Ratajczyk, Pawel
Fedorczak, Michal
Kluj, Przemyslaw
Gaszynski, Tomasz
author_facet Ratajczyk, Pawel
Fedorczak, Michal
Kluj, Przemyslaw
Gaszynski, Tomasz
author_sort Ratajczyk, Pawel
collection PubMed
description BACKGROUND: New devices are more available in the pre-hospital environment operational theaters and emergency departments. One is an intubrite laryngoscope (INT) with Dual LED lighting that combines ultraviolet and white LED. The study aimed to compare the efficacy of endotracheal intubation using INT and conventional laryngoscope performed by inexperienced paramedics (paramedics students) and paramedics with experience in advanced airways management in full and limited accessibility settings. METHODS: It was an open, prospective, crossover manikin study. Sixty paramedics and paramedic students were recruited. Participants were divided into 2 equal groups depending on their experience (n = 30). Experienced participants were further randomly divided into 2 groups (n = 15). Inexperienced participants were also randomly divided into 2 groups (n = 15). The criterion of inexperience was 5 or fewer intubation by any laryngoscope. Inexperience participants were asked to perform tracheal intubation in standard pre-hospital settings (without limited access to manikin) (scenario A) and difficult pre-hospital settings (limited access to manikin - narrow space between benches) (scenario B). Experience participants were asked to intubate manikin in difficult pre-hospital settings. RESULTS: In the normal pre-hospital environment, the success rate after the first attempt was 56,7% for conventional laryngoscope and 66,7% for intubrite. However, the overall effectiveness of tracheal intubation using both laryngoscopes in 3 attempts was 90% for both devices. The successful rate of first attempt intubation in a difficult environment by inexperienced was 73,3% for INT and 50% for conventional laryngoscope. Overall effectiveness was 83,3% and 86,7% respectively. The successful rate of first attempt intubation in the experienced group was 86,7% with INT compared to 60% with a conventional laryngoscope in difficult settings. Overall effectiveness was 96,7% for both devices. CONCLUSION: Intubrite provided better working conditions and make up for deficiencies in successful tracheal intubation by inexperienced participants in a normal and difficult environment. Tracheal intubation with intubrite was more effective in the experienced group. Tracheal intubation effectiveness with intubrite was also higher in the experienced group.
format Online
Article
Text
id pubmed-10637480
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-106374802023-11-15 A comparison of tracheal intubation using intubrite laryngoscope and conventional MAC laryngoscope: An open, prospective, crossover manikin study Ratajczyk, Pawel Fedorczak, Michal Kluj, Przemyslaw Gaszynski, Tomasz Medicine (Baltimore) 3900 BACKGROUND: New devices are more available in the pre-hospital environment operational theaters and emergency departments. One is an intubrite laryngoscope (INT) with Dual LED lighting that combines ultraviolet and white LED. The study aimed to compare the efficacy of endotracheal intubation using INT and conventional laryngoscope performed by inexperienced paramedics (paramedics students) and paramedics with experience in advanced airways management in full and limited accessibility settings. METHODS: It was an open, prospective, crossover manikin study. Sixty paramedics and paramedic students were recruited. Participants were divided into 2 equal groups depending on their experience (n = 30). Experienced participants were further randomly divided into 2 groups (n = 15). Inexperienced participants were also randomly divided into 2 groups (n = 15). The criterion of inexperience was 5 or fewer intubation by any laryngoscope. Inexperience participants were asked to perform tracheal intubation in standard pre-hospital settings (without limited access to manikin) (scenario A) and difficult pre-hospital settings (limited access to manikin - narrow space between benches) (scenario B). Experience participants were asked to intubate manikin in difficult pre-hospital settings. RESULTS: In the normal pre-hospital environment, the success rate after the first attempt was 56,7% for conventional laryngoscope and 66,7% for intubrite. However, the overall effectiveness of tracheal intubation using both laryngoscopes in 3 attempts was 90% for both devices. The successful rate of first attempt intubation in a difficult environment by inexperienced was 73,3% for INT and 50% for conventional laryngoscope. Overall effectiveness was 83,3% and 86,7% respectively. The successful rate of first attempt intubation in the experienced group was 86,7% with INT compared to 60% with a conventional laryngoscope in difficult settings. Overall effectiveness was 96,7% for both devices. CONCLUSION: Intubrite provided better working conditions and make up for deficiencies in successful tracheal intubation by inexperienced participants in a normal and difficult environment. Tracheal intubation with intubrite was more effective in the experienced group. Tracheal intubation effectiveness with intubrite was also higher in the experienced group. Lippincott Williams & Wilkins 2023-11-10 /pmc/articles/PMC10637480/ /pubmed/37960794 http://dx.doi.org/10.1097/MD.0000000000035846 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle 3900
Ratajczyk, Pawel
Fedorczak, Michal
Kluj, Przemyslaw
Gaszynski, Tomasz
A comparison of tracheal intubation using intubrite laryngoscope and conventional MAC laryngoscope: An open, prospective, crossover manikin study
title A comparison of tracheal intubation using intubrite laryngoscope and conventional MAC laryngoscope: An open, prospective, crossover manikin study
title_full A comparison of tracheal intubation using intubrite laryngoscope and conventional MAC laryngoscope: An open, prospective, crossover manikin study
title_fullStr A comparison of tracheal intubation using intubrite laryngoscope and conventional MAC laryngoscope: An open, prospective, crossover manikin study
title_full_unstemmed A comparison of tracheal intubation using intubrite laryngoscope and conventional MAC laryngoscope: An open, prospective, crossover manikin study
title_short A comparison of tracheal intubation using intubrite laryngoscope and conventional MAC laryngoscope: An open, prospective, crossover manikin study
title_sort comparison of tracheal intubation using intubrite laryngoscope and conventional mac laryngoscope: an open, prospective, crossover manikin study
topic 3900
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10637480/
https://www.ncbi.nlm.nih.gov/pubmed/37960794
http://dx.doi.org/10.1097/MD.0000000000035846
work_keys_str_mv AT ratajczykpawel acomparisonoftrachealintubationusingintubritelaryngoscopeandconventionalmaclaryngoscopeanopenprospectivecrossovermanikinstudy
AT fedorczakmichal acomparisonoftrachealintubationusingintubritelaryngoscopeandconventionalmaclaryngoscopeanopenprospectivecrossovermanikinstudy
AT klujprzemyslaw acomparisonoftrachealintubationusingintubritelaryngoscopeandconventionalmaclaryngoscopeanopenprospectivecrossovermanikinstudy
AT gaszynskitomasz acomparisonoftrachealintubationusingintubritelaryngoscopeandconventionalmaclaryngoscopeanopenprospectivecrossovermanikinstudy
AT ratajczykpawel comparisonoftrachealintubationusingintubritelaryngoscopeandconventionalmaclaryngoscopeanopenprospectivecrossovermanikinstudy
AT fedorczakmichal comparisonoftrachealintubationusingintubritelaryngoscopeandconventionalmaclaryngoscopeanopenprospectivecrossovermanikinstudy
AT klujprzemyslaw comparisonoftrachealintubationusingintubritelaryngoscopeandconventionalmaclaryngoscopeanopenprospectivecrossovermanikinstudy
AT gaszynskitomasz comparisonoftrachealintubationusingintubritelaryngoscopeandconventionalmaclaryngoscopeanopenprospectivecrossovermanikinstudy