Concordance of shoulder strength assessments using a spring balance and isometric dynamometer in patients before and after arthroscopic rotator cuff repair

BACKGROUND: Shoulder strength is an essential assessment to monitor the outcome of treatment interventions. Isometric strength assessment in the Constant Score (CS) was initially measured with a cable tensiometer or spring balance (SB). Some authors have questioned the validity of this strength asse...

Descripción completa

Detalles Bibliográficos
Autores principales: Child, Christopher, Scheibel, Markus, Wehrli, Martina, de Jong, Marije, Brune, Daniela, Endell, David, Audigé, Laurent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10638569/
https://www.ncbi.nlm.nih.gov/pubmed/37969520
http://dx.doi.org/10.1016/j.jseint.2023.06.017
_version_ 1785146589071802368
author Child, Christopher
Scheibel, Markus
Wehrli, Martina
de Jong, Marije
Brune, Daniela
Endell, David
Audigé, Laurent
author_facet Child, Christopher
Scheibel, Markus
Wehrli, Martina
de Jong, Marije
Brune, Daniela
Endell, David
Audigé, Laurent
author_sort Child, Christopher
collection PubMed
description BACKGROUND: Shoulder strength is an essential assessment to monitor the outcome of treatment interventions. Isometric strength assessment in the Constant Score (CS) was initially measured with a cable tensiometer or spring balance (SB). Some authors have questioned the validity of this strength assessment and the resulting CS. The purpose of this study was to investigate the concordance of strength measurements using an unsecured SB vs. isometric dynamometer and outline the impact of these methods on the CS. METHODS: In the context of routine clinical examination as well as participation in a Swiss national cohort study, shoulder strength was measured to calculate baseline (before surgery) and 6-month postoperative CS in adult rotator cuff tear patients who had undergone primary arthroscopic rotator cuff repair. Measurements of each of the operated and contralateral shoulders were made per patient routinely using an unsecured SB and study-specific using an isometric dynamometer in patients with the shoulder at 90° abduction in the scapular plane. Absolute and change values of strength and CS data were presented in scatter plots and assessed using concordance correlation coefficients (CCCs) and Bland-Altman plots. RESULTS: Between June 2020 and October 2021, baseline strength measurements from the operated shoulder of 78 patients ranged from 0.0 to 13.6 kg with a CCC of 0.64 (P < .001) and a mean difference of 0.81 kg between the SB and dynamometer methods. There were 89 measurements of the contralateral healthy shoulder that ranged from 3.6 to 15.6 kg; CCC and mean strength difference were 0.76 (P < .001) and 0.70 kg, respectively. At 6 months postsurgery, strength measurements of the operated shoulder ranged from 1.4 to 12.0 kg with a CCC of 0.66 (P < .001) and mean strength difference of 0.9 kg (n = 68). Respective 6-month measurements of the contralateral side (n = 52) ranged from 2.0 to 15.9 kg with a CCC of 0.73 (P < .001) and mean strength difference of 0.03 kg. CONCLUSION: Absolute and change values in shoulder strength assessments using an unsecured SB and isometric dynamometer are fairly concordant with mean differences of less than 1 kg between methods. With the variability of strength differences among patients, interpretation of these values for individual patients may be challenging. Nonetheless, unsecured SB and dynamometer methods share only slight and clinically unimportant differences that can provide similar group mean values for use in research along with the calculation of the CS.
format Online
Article
Text
id pubmed-10638569
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106385692023-11-15 Concordance of shoulder strength assessments using a spring balance and isometric dynamometer in patients before and after arthroscopic rotator cuff repair Child, Christopher Scheibel, Markus Wehrli, Martina de Jong, Marije Brune, Daniela Endell, David Audigé, Laurent JSES Int Shoulder BACKGROUND: Shoulder strength is an essential assessment to monitor the outcome of treatment interventions. Isometric strength assessment in the Constant Score (CS) was initially measured with a cable tensiometer or spring balance (SB). Some authors have questioned the validity of this strength assessment and the resulting CS. The purpose of this study was to investigate the concordance of strength measurements using an unsecured SB vs. isometric dynamometer and outline the impact of these methods on the CS. METHODS: In the context of routine clinical examination as well as participation in a Swiss national cohort study, shoulder strength was measured to calculate baseline (before surgery) and 6-month postoperative CS in adult rotator cuff tear patients who had undergone primary arthroscopic rotator cuff repair. Measurements of each of the operated and contralateral shoulders were made per patient routinely using an unsecured SB and study-specific using an isometric dynamometer in patients with the shoulder at 90° abduction in the scapular plane. Absolute and change values of strength and CS data were presented in scatter plots and assessed using concordance correlation coefficients (CCCs) and Bland-Altman plots. RESULTS: Between June 2020 and October 2021, baseline strength measurements from the operated shoulder of 78 patients ranged from 0.0 to 13.6 kg with a CCC of 0.64 (P < .001) and a mean difference of 0.81 kg between the SB and dynamometer methods. There were 89 measurements of the contralateral healthy shoulder that ranged from 3.6 to 15.6 kg; CCC and mean strength difference were 0.76 (P < .001) and 0.70 kg, respectively. At 6 months postsurgery, strength measurements of the operated shoulder ranged from 1.4 to 12.0 kg with a CCC of 0.66 (P < .001) and mean strength difference of 0.9 kg (n = 68). Respective 6-month measurements of the contralateral side (n = 52) ranged from 2.0 to 15.9 kg with a CCC of 0.73 (P < .001) and mean strength difference of 0.03 kg. CONCLUSION: Absolute and change values in shoulder strength assessments using an unsecured SB and isometric dynamometer are fairly concordant with mean differences of less than 1 kg between methods. With the variability of strength differences among patients, interpretation of these values for individual patients may be challenging. Nonetheless, unsecured SB and dynamometer methods share only slight and clinically unimportant differences that can provide similar group mean values for use in research along with the calculation of the CS. Elsevier 2023-07-17 /pmc/articles/PMC10638569/ /pubmed/37969520 http://dx.doi.org/10.1016/j.jseint.2023.06.017 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Shoulder
Child, Christopher
Scheibel, Markus
Wehrli, Martina
de Jong, Marije
Brune, Daniela
Endell, David
Audigé, Laurent
Concordance of shoulder strength assessments using a spring balance and isometric dynamometer in patients before and after arthroscopic rotator cuff repair
title Concordance of shoulder strength assessments using a spring balance and isometric dynamometer in patients before and after arthroscopic rotator cuff repair
title_full Concordance of shoulder strength assessments using a spring balance and isometric dynamometer in patients before and after arthroscopic rotator cuff repair
title_fullStr Concordance of shoulder strength assessments using a spring balance and isometric dynamometer in patients before and after arthroscopic rotator cuff repair
title_full_unstemmed Concordance of shoulder strength assessments using a spring balance and isometric dynamometer in patients before and after arthroscopic rotator cuff repair
title_short Concordance of shoulder strength assessments using a spring balance and isometric dynamometer in patients before and after arthroscopic rotator cuff repair
title_sort concordance of shoulder strength assessments using a spring balance and isometric dynamometer in patients before and after arthroscopic rotator cuff repair
topic Shoulder
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10638569/
https://www.ncbi.nlm.nih.gov/pubmed/37969520
http://dx.doi.org/10.1016/j.jseint.2023.06.017
work_keys_str_mv AT childchristopher concordanceofshoulderstrengthassessmentsusingaspringbalanceandisometricdynamometerinpatientsbeforeandafterarthroscopicrotatorcuffrepair
AT scheibelmarkus concordanceofshoulderstrengthassessmentsusingaspringbalanceandisometricdynamometerinpatientsbeforeandafterarthroscopicrotatorcuffrepair
AT wehrlimartina concordanceofshoulderstrengthassessmentsusingaspringbalanceandisometricdynamometerinpatientsbeforeandafterarthroscopicrotatorcuffrepair
AT dejongmarije concordanceofshoulderstrengthassessmentsusingaspringbalanceandisometricdynamometerinpatientsbeforeandafterarthroscopicrotatorcuffrepair
AT brunedaniela concordanceofshoulderstrengthassessmentsusingaspringbalanceandisometricdynamometerinpatientsbeforeandafterarthroscopicrotatorcuffrepair
AT endelldavid concordanceofshoulderstrengthassessmentsusingaspringbalanceandisometricdynamometerinpatientsbeforeandafterarthroscopicrotatorcuffrepair
AT audigelaurent concordanceofshoulderstrengthassessmentsusingaspringbalanceandisometricdynamometerinpatientsbeforeandafterarthroscopicrotatorcuffrepair