Cargando…

Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy

BACKGROUND: Surgeon visual estimation of shoulder range of motion (ROM) is commonplace in the outpatient office setting and routinely reported in clinical research, but the reliability and accuracy of this practice remain unclear. The purpose of this study is to establish the reliability and accurac...

Descripción completa

Detalles Bibliográficos
Autores principales: Hwang, Simon, Ardebol, Javier, Ghayyad, Kassem, Pak, Theresa, Bonadiman, Joao A., Denard, Patrick J., Menendez, Mariano E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10638579/
https://www.ncbi.nlm.nih.gov/pubmed/37969522
http://dx.doi.org/10.1016/j.jseint.2023.07.002
_version_ 1785146591578947584
author Hwang, Simon
Ardebol, Javier
Ghayyad, Kassem
Pak, Theresa
Bonadiman, Joao A.
Denard, Patrick J.
Menendez, Mariano E.
author_facet Hwang, Simon
Ardebol, Javier
Ghayyad, Kassem
Pak, Theresa
Bonadiman, Joao A.
Denard, Patrick J.
Menendez, Mariano E.
author_sort Hwang, Simon
collection PubMed
description BACKGROUND: Surgeon visual estimation of shoulder range of motion (ROM) is commonplace in the outpatient office setting and routinely reported in clinical research, but the reliability and accuracy of this practice remain unclear. The purpose of this study is to establish the reliability and accuracy of remote visual estimation of shoulder ROM in healthy volunteers and symptomatic patients among a large group of shoulder surgeons. Our hypothesis is that remote visual estimation would be reliable and accurate compared with the digital goniometer method. METHODS: Fifty shoulder surgeon members of the PacWest Shoulder and Elbow Society independently determined the active shoulder forward flexion (FF), internal rotation at 90° abduction (IR90), external rotation at 90° abduction, external rotation at the side , and maximal spinal level reached with internal rotation (IR(spine)) through visual estimation of video recordings taken from 10 healthy volunteers and 10 symptomatic patients. Variations in measurements were quantified using the interobserver reliability through calculation of the intraclass correlation coefficient. Accuracy was determined through comparison with digital goniometer measurements obtained with an on-screen protractor application using Bland–Altman mean differences and 95% limits of agreement. RESULTS: The interobserver reliability among examiners showed moderate to excellent correlation, with intraclass correlation coefficient ranging from 0.768 to 0.928 for the healthy volunteers and 0.739 to 0.878 for the symptomatic patients. Accuracy was limited, with upper limits of agreement exceeding the established minimal clinically important differences (MCIDs) for FF (20° vs. MCID of 14°) and IR90 (25° vs. 18°) in the healthy volunteers and for FF (33° vs. 16°), external rotation at 90° abduction (21° vs. 18°), and IR90 (31° vs. 20°) in the symptomatic patients. CONCLUSION: Despite generally high intersurgeon reliability in the visual estimation of shoulder ROM, there was questionable accuracy when compared to digital goniometer measurements,with measurement errors often exceeding established MCID values. Given the potential implications for the clinical response to treatment and the significance of research findings, the adoption of validated instruments to measure ROM and the standardization of examination procedures should be considered.
format Online
Article
Text
id pubmed-10638579
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106385792023-11-15 Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy Hwang, Simon Ardebol, Javier Ghayyad, Kassem Pak, Theresa Bonadiman, Joao A. Denard, Patrick J. Menendez, Mariano E. JSES Int Shoulder BACKGROUND: Surgeon visual estimation of shoulder range of motion (ROM) is commonplace in the outpatient office setting and routinely reported in clinical research, but the reliability and accuracy of this practice remain unclear. The purpose of this study is to establish the reliability and accuracy of remote visual estimation of shoulder ROM in healthy volunteers and symptomatic patients among a large group of shoulder surgeons. Our hypothesis is that remote visual estimation would be reliable and accurate compared with the digital goniometer method. METHODS: Fifty shoulder surgeon members of the PacWest Shoulder and Elbow Society independently determined the active shoulder forward flexion (FF), internal rotation at 90° abduction (IR90), external rotation at 90° abduction, external rotation at the side , and maximal spinal level reached with internal rotation (IR(spine)) through visual estimation of video recordings taken from 10 healthy volunteers and 10 symptomatic patients. Variations in measurements were quantified using the interobserver reliability through calculation of the intraclass correlation coefficient. Accuracy was determined through comparison with digital goniometer measurements obtained with an on-screen protractor application using Bland–Altman mean differences and 95% limits of agreement. RESULTS: The interobserver reliability among examiners showed moderate to excellent correlation, with intraclass correlation coefficient ranging from 0.768 to 0.928 for the healthy volunteers and 0.739 to 0.878 for the symptomatic patients. Accuracy was limited, with upper limits of agreement exceeding the established minimal clinically important differences (MCIDs) for FF (20° vs. MCID of 14°) and IR90 (25° vs. 18°) in the healthy volunteers and for FF (33° vs. 16°), external rotation at 90° abduction (21° vs. 18°), and IR90 (31° vs. 20°) in the symptomatic patients. CONCLUSION: Despite generally high intersurgeon reliability in the visual estimation of shoulder ROM, there was questionable accuracy when compared to digital goniometer measurements,with measurement errors often exceeding established MCID values. Given the potential implications for the clinical response to treatment and the significance of research findings, the adoption of validated instruments to measure ROM and the standardization of examination procedures should be considered. Elsevier 2023-07-29 /pmc/articles/PMC10638579/ /pubmed/37969522 http://dx.doi.org/10.1016/j.jseint.2023.07.002 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Shoulder
Hwang, Simon
Ardebol, Javier
Ghayyad, Kassem
Pak, Theresa
Bonadiman, Joao A.
Denard, Patrick J.
Menendez, Mariano E.
Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy
title Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy
title_full Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy
title_fullStr Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy
title_full_unstemmed Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy
title_short Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy
title_sort remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy
topic Shoulder
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10638579/
https://www.ncbi.nlm.nih.gov/pubmed/37969522
http://dx.doi.org/10.1016/j.jseint.2023.07.002
work_keys_str_mv AT hwangsimon remotevisualestimationofshoulderrangeofmotionhasgenerallyhighinterobserverreliabilitybutlimitedaccuracy
AT ardeboljavier remotevisualestimationofshoulderrangeofmotionhasgenerallyhighinterobserverreliabilitybutlimitedaccuracy
AT ghayyadkassem remotevisualestimationofshoulderrangeofmotionhasgenerallyhighinterobserverreliabilitybutlimitedaccuracy
AT paktheresa remotevisualestimationofshoulderrangeofmotionhasgenerallyhighinterobserverreliabilitybutlimitedaccuracy
AT bonadimanjoaoa remotevisualestimationofshoulderrangeofmotionhasgenerallyhighinterobserverreliabilitybutlimitedaccuracy
AT denardpatrickj remotevisualestimationofshoulderrangeofmotionhasgenerallyhighinterobserverreliabilitybutlimitedaccuracy
AT menendezmarianoe remotevisualestimationofshoulderrangeofmotionhasgenerallyhighinterobserverreliabilitybutlimitedaccuracy
AT remotevisualestimationofshoulderrangeofmotionhasgenerallyhighinterobserverreliabilitybutlimitedaccuracy