Cargando…

Biomechanical properties of suprapectoral biceps tenodesis with double-anchor knotless luggage tag sutures vs. subpectoral biceps tenodesis with single-anchor whipstitch suture using all-suture anchors

BACKGROUND: As the use of all-suture anchors continues to increase, limited biomechanical data on the use of these anchors in various configurations for tenodesis of the long head biceps tendon (LHBT) exists. The aim of this study was to compare the biomechanical properties of a 2-anchor luggage tag...

Descripción completa

Detalles Bibliográficos
Autores principales: Nicolay, Richard W., Jahandar, Amirhossein, Retzky, Julia S., Kontaxis, Andreas, Verma, Nikhil N., Fu, Michael C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10638590/
https://www.ncbi.nlm.nih.gov/pubmed/37969507
http://dx.doi.org/10.1016/j.jseint.2023.07.013
_version_ 1785146594116501504
author Nicolay, Richard W.
Jahandar, Amirhossein
Retzky, Julia S.
Kontaxis, Andreas
Verma, Nikhil N.
Fu, Michael C.
author_facet Nicolay, Richard W.
Jahandar, Amirhossein
Retzky, Julia S.
Kontaxis, Andreas
Verma, Nikhil N.
Fu, Michael C.
author_sort Nicolay, Richard W.
collection PubMed
description BACKGROUND: As the use of all-suture anchors continues to increase, limited biomechanical data on the use of these anchors in various configurations for tenodesis of the long head biceps tendon (LHBT) exists. The aim of this study was to compare the biomechanical properties of a 2-anchor luggage tag suprapectoral biceps tenodesis (Sup-BT) vs. a single-anchor whipstitch subpectoral biceps tenodesis (Sub-BT) using all-suture anchors. The hypothesis was that the Sub-BT will have a higher ultimate load to failure and less creep relative to the Sup-BT construct. METHODS: Eighteen fresh frozen cadaveric humeri were used. The specimens were randomly divided into 2 groups of 9; i) The Sup-BT were performed with 2 1.8 mm knotless all-suture anchors using a luggage-tag fixation configuration, ii) The Sub-BT were performed using a single 1.9 mm all-suture anchor and a whipstitch suture configuration with a tied knot. The humeri were tested on a hydraulic MTS machine where the specimens were preloaded at 5 N for 2 minutes and then cyclically loaded from 5 to 50 N for 1000 cycles at 1 Hz while maximum displacement was recorded with a motion system and markers attached to the bone and bicep tendon. The tendon was then tensioned at a rate of 1 mm/s to obtain the ultimate load to failure. CT scans of the specimens were used to calculate the bone mineral density at the site of the anchor/bone interface and video recordings were captured during load to failure to document all modes of failure. RESULTS: There was no significant difference in the average load to failure of the Sup-BT and Sub-BT groups (197 N ± 45 N (SD), 164 N ± 68 N (SD) respectively; P = .122) or creep under fatigue between the Sup-BT vs. Sub-BT specimens (3.1 mm, SD = 1.5 vs. 2.2 mm, SD = 0.9; P = .162). The bone mineral density was statistically different between the 2 groups (P < .001); however, there were no observed failures at the anchor/bone interface and no correlation between failure load and bone mineral density. CONCLUSION: The ultimate load to failure and creep between a Sup-BT with 2 knotless all-suture anchors using a luggage tag suture configuration was equivalent to a Sub-BT with 1 all-suture anchor using a whipstitched suture configuration and a tied knot. Surgeons can perform either technique confidently knowing that they are biomechanically equivalent in a cadaver model at time zero, and they offer similar strength to other fixation methods cited in the literature.
format Online
Article
Text
id pubmed-10638590
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106385902023-11-15 Biomechanical properties of suprapectoral biceps tenodesis with double-anchor knotless luggage tag sutures vs. subpectoral biceps tenodesis with single-anchor whipstitch suture using all-suture anchors Nicolay, Richard W. Jahandar, Amirhossein Retzky, Julia S. Kontaxis, Andreas Verma, Nikhil N. Fu, Michael C. JSES Int Shoulder BACKGROUND: As the use of all-suture anchors continues to increase, limited biomechanical data on the use of these anchors in various configurations for tenodesis of the long head biceps tendon (LHBT) exists. The aim of this study was to compare the biomechanical properties of a 2-anchor luggage tag suprapectoral biceps tenodesis (Sup-BT) vs. a single-anchor whipstitch subpectoral biceps tenodesis (Sub-BT) using all-suture anchors. The hypothesis was that the Sub-BT will have a higher ultimate load to failure and less creep relative to the Sup-BT construct. METHODS: Eighteen fresh frozen cadaveric humeri were used. The specimens were randomly divided into 2 groups of 9; i) The Sup-BT were performed with 2 1.8 mm knotless all-suture anchors using a luggage-tag fixation configuration, ii) The Sub-BT were performed using a single 1.9 mm all-suture anchor and a whipstitch suture configuration with a tied knot. The humeri were tested on a hydraulic MTS machine where the specimens were preloaded at 5 N for 2 minutes and then cyclically loaded from 5 to 50 N for 1000 cycles at 1 Hz while maximum displacement was recorded with a motion system and markers attached to the bone and bicep tendon. The tendon was then tensioned at a rate of 1 mm/s to obtain the ultimate load to failure. CT scans of the specimens were used to calculate the bone mineral density at the site of the anchor/bone interface and video recordings were captured during load to failure to document all modes of failure. RESULTS: There was no significant difference in the average load to failure of the Sup-BT and Sub-BT groups (197 N ± 45 N (SD), 164 N ± 68 N (SD) respectively; P = .122) or creep under fatigue between the Sup-BT vs. Sub-BT specimens (3.1 mm, SD = 1.5 vs. 2.2 mm, SD = 0.9; P = .162). The bone mineral density was statistically different between the 2 groups (P < .001); however, there were no observed failures at the anchor/bone interface and no correlation between failure load and bone mineral density. CONCLUSION: The ultimate load to failure and creep between a Sup-BT with 2 knotless all-suture anchors using a luggage tag suture configuration was equivalent to a Sub-BT with 1 all-suture anchor using a whipstitched suture configuration and a tied knot. Surgeons can perform either technique confidently knowing that they are biomechanically equivalent in a cadaver model at time zero, and they offer similar strength to other fixation methods cited in the literature. Elsevier 2023-08-03 /pmc/articles/PMC10638590/ /pubmed/37969507 http://dx.doi.org/10.1016/j.jseint.2023.07.013 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Shoulder
Nicolay, Richard W.
Jahandar, Amirhossein
Retzky, Julia S.
Kontaxis, Andreas
Verma, Nikhil N.
Fu, Michael C.
Biomechanical properties of suprapectoral biceps tenodesis with double-anchor knotless luggage tag sutures vs. subpectoral biceps tenodesis with single-anchor whipstitch suture using all-suture anchors
title Biomechanical properties of suprapectoral biceps tenodesis with double-anchor knotless luggage tag sutures vs. subpectoral biceps tenodesis with single-anchor whipstitch suture using all-suture anchors
title_full Biomechanical properties of suprapectoral biceps tenodesis with double-anchor knotless luggage tag sutures vs. subpectoral biceps tenodesis with single-anchor whipstitch suture using all-suture anchors
title_fullStr Biomechanical properties of suprapectoral biceps tenodesis with double-anchor knotless luggage tag sutures vs. subpectoral biceps tenodesis with single-anchor whipstitch suture using all-suture anchors
title_full_unstemmed Biomechanical properties of suprapectoral biceps tenodesis with double-anchor knotless luggage tag sutures vs. subpectoral biceps tenodesis with single-anchor whipstitch suture using all-suture anchors
title_short Biomechanical properties of suprapectoral biceps tenodesis with double-anchor knotless luggage tag sutures vs. subpectoral biceps tenodesis with single-anchor whipstitch suture using all-suture anchors
title_sort biomechanical properties of suprapectoral biceps tenodesis with double-anchor knotless luggage tag sutures vs. subpectoral biceps tenodesis with single-anchor whipstitch suture using all-suture anchors
topic Shoulder
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10638590/
https://www.ncbi.nlm.nih.gov/pubmed/37969507
http://dx.doi.org/10.1016/j.jseint.2023.07.013
work_keys_str_mv AT nicolayrichardw biomechanicalpropertiesofsuprapectoralbicepstenodesiswithdoubleanchorknotlessluggagetagsuturesvssubpectoralbicepstenodesiswithsingleanchorwhipstitchsutureusingallsutureanchors
AT jahandaramirhossein biomechanicalpropertiesofsuprapectoralbicepstenodesiswithdoubleanchorknotlessluggagetagsuturesvssubpectoralbicepstenodesiswithsingleanchorwhipstitchsutureusingallsutureanchors
AT retzkyjulias biomechanicalpropertiesofsuprapectoralbicepstenodesiswithdoubleanchorknotlessluggagetagsuturesvssubpectoralbicepstenodesiswithsingleanchorwhipstitchsutureusingallsutureanchors
AT kontaxisandreas biomechanicalpropertiesofsuprapectoralbicepstenodesiswithdoubleanchorknotlessluggagetagsuturesvssubpectoralbicepstenodesiswithsingleanchorwhipstitchsutureusingallsutureanchors
AT vermanikhiln biomechanicalpropertiesofsuprapectoralbicepstenodesiswithdoubleanchorknotlessluggagetagsuturesvssubpectoralbicepstenodesiswithsingleanchorwhipstitchsutureusingallsutureanchors
AT fumichaelc biomechanicalpropertiesofsuprapectoralbicepstenodesiswithdoubleanchorknotlessluggagetagsuturesvssubpectoralbicepstenodesiswithsingleanchorwhipstitchsutureusingallsutureanchors