Cargando…

Optic inversion of scleral-fixated intraocular lens after vitrectomy with fluid-air exchange: case series and review of the literature

Lens dislocation is a significant complication after cataract surgery. Scleral fixation of 3-piece intraocular lens provides favorable visual outcome and can spare patients the need for lens exchange. Two patients presented with dislocated 3-piece lenses implanted over 10 years earlier. Both patient...

Descripción completa

Detalles Bibliográficos
Autores principales: Cameron, Nathaniel W, Karadaghy, Amin, Mitchell, Mary K, Ajlan, Radwan S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10640673/
https://www.ncbi.nlm.nih.gov/pubmed/38026751
http://dx.doi.org/10.1093/jscr/rjad600
Descripción
Sumario:Lens dislocation is a significant complication after cataract surgery. Scleral fixation of 3-piece intraocular lens provides favorable visual outcome and can spare patients the need for lens exchange. Two patients presented with dislocated 3-piece lenses implanted over 10 years earlier. Both patients underwent pars plana vitrectomy and dropped lens rescue with scleral fixation. Postoperatively, the lens optic was found flipped nearly 90° at the optic-haptic junctions secondary to fluid-air exchange performed during vitrectomy. Both patients underwent intraocular lens exchange with a four point sclera fixated lens. Our study found that air tamponade is better avoided during rescue of old dislocated 3-piece lens implants. Intraocular lens exchange is preferred, when possible, to avoid complications associated with old dislocated lenses. Larger studies are needed to determine the effect of time on dislocated lens implants materials.