Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones

We describe a case of an abdominal aortic aneurysm (AAA) and angulated proximal neck treated with a Gore Excluder conformable endoprosthesis and show relevant technical pitfalls in the deployment of the graft main body. An 82-year-old man presented with a 71-mm asymptomatic AAA with an angulated inf...

Descripción completa

Detalles Bibliográficos
Autores principales: Vacirca, Andrea, Sulzer, Titia A.L., Mesnard, Thomas, Baghbani-Oskouei, Aidin, Ocasio, Laura, Macedo, Thanila A., Verhagen, Hence J.M., Rhee, Robert, Oderich, Gustavo S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10641676/
https://www.ncbi.nlm.nih.gov/pubmed/37965112
http://dx.doi.org/10.1016/j.jvscit.2023.101339
_version_ 1785146807751278592
author Vacirca, Andrea
Sulzer, Titia A.L.
Mesnard, Thomas
Baghbani-Oskouei, Aidin
Ocasio, Laura
Macedo, Thanila A.
Verhagen, Hence J.M.
Rhee, Robert
Oderich, Gustavo S.
author_facet Vacirca, Andrea
Sulzer, Titia A.L.
Mesnard, Thomas
Baghbani-Oskouei, Aidin
Ocasio, Laura
Macedo, Thanila A.
Verhagen, Hence J.M.
Rhee, Robert
Oderich, Gustavo S.
author_sort Vacirca, Andrea
collection PubMed
description We describe a case of an abdominal aortic aneurysm (AAA) and angulated proximal neck treated with a Gore Excluder conformable endoprosthesis and show relevant technical pitfalls in the deployment of the graft main body. An 82-year-old man presented with a 71-mm asymptomatic AAA with an angulated infrarenal proximal neck (75°) and was referred to our unit. The patient was treated with a 26-mm Gore Excluder conformable device, which was deployed slightly above the renal arteries after precatheterization of the lowest renal artery. The graft was then repositioned with support of the introducer sheath and a stiff guide wire. The proximal sealing zone was ballooned before the endograft delivery system was retrieved to avoid distal migration. Technical success was achieved. The patient was discharged with no complications. No type Ia endoleak was present on the 6-month computed tomography scan. Endovascular treatment of an AAA with a severe angulated proximal neck can be effective with a conformable stent graft if technical measures are used during deployment of the main body to optimize the seal.
format Online
Article
Text
id pubmed-10641676
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106416762023-11-14 Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones Vacirca, Andrea Sulzer, Titia A.L. Mesnard, Thomas Baghbani-Oskouei, Aidin Ocasio, Laura Macedo, Thanila A. Verhagen, Hence J.M. Rhee, Robert Oderich, Gustavo S. J Vasc Surg Cases Innov Tech Case report We describe a case of an abdominal aortic aneurysm (AAA) and angulated proximal neck treated with a Gore Excluder conformable endoprosthesis and show relevant technical pitfalls in the deployment of the graft main body. An 82-year-old man presented with a 71-mm asymptomatic AAA with an angulated infrarenal proximal neck (75°) and was referred to our unit. The patient was treated with a 26-mm Gore Excluder conformable device, which was deployed slightly above the renal arteries after precatheterization of the lowest renal artery. The graft was then repositioned with support of the introducer sheath and a stiff guide wire. The proximal sealing zone was ballooned before the endograft delivery system was retrieved to avoid distal migration. Technical success was achieved. The patient was discharged with no complications. No type Ia endoleak was present on the 6-month computed tomography scan. Endovascular treatment of an AAA with a severe angulated proximal neck can be effective with a conformable stent graft if technical measures are used during deployment of the main body to optimize the seal. Elsevier 2023-09-29 /pmc/articles/PMC10641676/ /pubmed/37965112 http://dx.doi.org/10.1016/j.jvscit.2023.101339 Text en © 2023 Published by Elsevier Inc. on behalf of Society for Vascular Surgery. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case report
Vacirca, Andrea
Sulzer, Titia A.L.
Mesnard, Thomas
Baghbani-Oskouei, Aidin
Ocasio, Laura
Macedo, Thanila A.
Verhagen, Hence J.M.
Rhee, Robert
Oderich, Gustavo S.
Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones
title Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones
title_full Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones
title_fullStr Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones
title_full_unstemmed Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones
title_short Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones
title_sort technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the gore excluder conformable device in angulated and short landing zones
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10641676/
https://www.ncbi.nlm.nih.gov/pubmed/37965112
http://dx.doi.org/10.1016/j.jvscit.2023.101339
work_keys_str_mv AT vacircaandrea technicalpitfallsandproposedmodificationsofinstructionsforuseforendovascularaorticaneurysmrepairusingthegoreexcluderconformabledeviceinangulatedandshortlandingzones
AT sulzertitiaal technicalpitfallsandproposedmodificationsofinstructionsforuseforendovascularaorticaneurysmrepairusingthegoreexcluderconformabledeviceinangulatedandshortlandingzones
AT mesnardthomas technicalpitfallsandproposedmodificationsofinstructionsforuseforendovascularaorticaneurysmrepairusingthegoreexcluderconformabledeviceinangulatedandshortlandingzones
AT baghbanioskoueiaidin technicalpitfallsandproposedmodificationsofinstructionsforuseforendovascularaorticaneurysmrepairusingthegoreexcluderconformabledeviceinangulatedandshortlandingzones
AT ocasiolaura technicalpitfallsandproposedmodificationsofinstructionsforuseforendovascularaorticaneurysmrepairusingthegoreexcluderconformabledeviceinangulatedandshortlandingzones
AT macedothanilaa technicalpitfallsandproposedmodificationsofinstructionsforuseforendovascularaorticaneurysmrepairusingthegoreexcluderconformabledeviceinangulatedandshortlandingzones
AT verhagenhencejm technicalpitfallsandproposedmodificationsofinstructionsforuseforendovascularaorticaneurysmrepairusingthegoreexcluderconformabledeviceinangulatedandshortlandingzones
AT rheerobert technicalpitfallsandproposedmodificationsofinstructionsforuseforendovascularaorticaneurysmrepairusingthegoreexcluderconformabledeviceinangulatedandshortlandingzones
AT oderichgustavos technicalpitfallsandproposedmodificationsofinstructionsforuseforendovascularaorticaneurysmrepairusingthegoreexcluderconformabledeviceinangulatedandshortlandingzones