Cargando…

Surface Analysis of a Universal Resin Composite and Effect of Preheating on its Physicochemical Properties

This study was aimed at analyzing the surface properties of a universal resin composite and evaluating the effect of preheating on its physicochemical properties. Two commercial resin composites were used under two conditions: Filtek Universal Restorative (UR); UR preheated (URH); Filtek Supreme (FS...

Descripción completa

Detalles Bibliográficos
Autores principales: da Silva, Marcus Vinícyus Manoel, Batista, João Marcos Nascimento, Fraga, May Anny Alves, Correr, Américo Bortolazzo, de Campos, Edson Alves, Geraldeli, Saulo, Sinhoreti, Mário Alexandre Coelho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Fundação Odontológica de Ribeirão Preto 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642265/
https://www.ncbi.nlm.nih.gov/pubmed/37909634
http://dx.doi.org/10.1590/0103-6440202305411
_version_ 1785146930219712512
author da Silva, Marcus Vinícyus Manoel
Batista, João Marcos Nascimento
Fraga, May Anny Alves
Correr, Américo Bortolazzo
de Campos, Edson Alves
Geraldeli, Saulo
Sinhoreti, Mário Alexandre Coelho
author_facet da Silva, Marcus Vinícyus Manoel
Batista, João Marcos Nascimento
Fraga, May Anny Alves
Correr, Américo Bortolazzo
de Campos, Edson Alves
Geraldeli, Saulo
Sinhoreti, Mário Alexandre Coelho
author_sort da Silva, Marcus Vinícyus Manoel
collection PubMed
description This study was aimed at analyzing the surface properties of a universal resin composite and evaluating the effect of preheating on its physicochemical properties. Two commercial resin composites were used under two conditions: Filtek Universal Restorative (UR); UR preheated (URH); Filtek Supreme (FS) and FS preheated (FSH). The film thickness (FT) test (n = 10) was done using two glass slabs under compression. Flexural strength (FLS) and modulus (FLM) were evaluated using a three-point flexion test (n = 10). Polymerization shrinkage stress (PSS) was evaluated in a universal testing machine (n = 5). Gap width (GW) between composite and mold was measured in internally polished metallic molds (n = 10). The degree of conversion (DC) was evaluated by Fourier Transform Infrared spectroscopy (n = 3). The morphology of the filler particles was checked by scanning electron microscope (SEM) and EDX analysis. Surface gloss (SG) and surface roughness (SR) were evaluated before and after mechanical brushing (n = 10). The outcomes were submitted to 2-way ANOVA and Tukey's test (α = 0.05). Lower mean values of FT were observed for the preheated groups when compared to the non-preheated groups. URH and FSH showed higher mean values of FLS and FLM when compared with UR and FS. No differences were observed between groups in the PSS test. The GW was higher for the UR and FS groups when compared with URH and FSH. The DC was higher for preheated resin composites when compared to the non-preheated groups. The SR of the UR composite was higher than the FS after mechanical brushing, while the SG was higher for the FS groups. In conclusion, the universal resin composite tested generally presented similar physicochemical properties compared with the nanofilled resin composite and either similar or slightly inferior surface properties. The preheating improved or maintained all properties evaluated.
format Online
Article
Text
id pubmed-10642265
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Fundação Odontológica de Ribeirão Preto
record_format MEDLINE/PubMed
spelling pubmed-106422652023-11-15 Surface Analysis of a Universal Resin Composite and Effect of Preheating on its Physicochemical Properties da Silva, Marcus Vinícyus Manoel Batista, João Marcos Nascimento Fraga, May Anny Alves Correr, Américo Bortolazzo de Campos, Edson Alves Geraldeli, Saulo Sinhoreti, Mário Alexandre Coelho Braz Dent J Article This study was aimed at analyzing the surface properties of a universal resin composite and evaluating the effect of preheating on its physicochemical properties. Two commercial resin composites were used under two conditions: Filtek Universal Restorative (UR); UR preheated (URH); Filtek Supreme (FS) and FS preheated (FSH). The film thickness (FT) test (n = 10) was done using two glass slabs under compression. Flexural strength (FLS) and modulus (FLM) were evaluated using a three-point flexion test (n = 10). Polymerization shrinkage stress (PSS) was evaluated in a universal testing machine (n = 5). Gap width (GW) between composite and mold was measured in internally polished metallic molds (n = 10). The degree of conversion (DC) was evaluated by Fourier Transform Infrared spectroscopy (n = 3). The morphology of the filler particles was checked by scanning electron microscope (SEM) and EDX analysis. Surface gloss (SG) and surface roughness (SR) were evaluated before and after mechanical brushing (n = 10). The outcomes were submitted to 2-way ANOVA and Tukey's test (α = 0.05). Lower mean values of FT were observed for the preheated groups when compared to the non-preheated groups. URH and FSH showed higher mean values of FLS and FLM when compared with UR and FS. No differences were observed between groups in the PSS test. The GW was higher for the UR and FS groups when compared with URH and FSH. The DC was higher for preheated resin composites when compared to the non-preheated groups. The SR of the UR composite was higher than the FS after mechanical brushing, while the SG was higher for the FS groups. In conclusion, the universal resin composite tested generally presented similar physicochemical properties compared with the nanofilled resin composite and either similar or slightly inferior surface properties. The preheating improved or maintained all properties evaluated. Fundação Odontológica de Ribeirão Preto 2023-10-27 /pmc/articles/PMC10642265/ /pubmed/37909634 http://dx.doi.org/10.1590/0103-6440202305411 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Article
da Silva, Marcus Vinícyus Manoel
Batista, João Marcos Nascimento
Fraga, May Anny Alves
Correr, Américo Bortolazzo
de Campos, Edson Alves
Geraldeli, Saulo
Sinhoreti, Mário Alexandre Coelho
Surface Analysis of a Universal Resin Composite and Effect of Preheating on its Physicochemical Properties
title Surface Analysis of a Universal Resin Composite and Effect of Preheating on its Physicochemical Properties
title_full Surface Analysis of a Universal Resin Composite and Effect of Preheating on its Physicochemical Properties
title_fullStr Surface Analysis of a Universal Resin Composite and Effect of Preheating on its Physicochemical Properties
title_full_unstemmed Surface Analysis of a Universal Resin Composite and Effect of Preheating on its Physicochemical Properties
title_short Surface Analysis of a Universal Resin Composite and Effect of Preheating on its Physicochemical Properties
title_sort surface analysis of a universal resin composite and effect of preheating on its physicochemical properties
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642265/
https://www.ncbi.nlm.nih.gov/pubmed/37909634
http://dx.doi.org/10.1590/0103-6440202305411
work_keys_str_mv AT dasilvamarcusvinicyusmanoel surfaceanalysisofauniversalresincompositeandeffectofpreheatingonitsphysicochemicalproperties
AT batistajoaomarcosnascimento surfaceanalysisofauniversalresincompositeandeffectofpreheatingonitsphysicochemicalproperties
AT fragamayannyalves surfaceanalysisofauniversalresincompositeandeffectofpreheatingonitsphysicochemicalproperties
AT correramericobortolazzo surfaceanalysisofauniversalresincompositeandeffectofpreheatingonitsphysicochemicalproperties
AT decamposedsonalves surfaceanalysisofauniversalresincompositeandeffectofpreheatingonitsphysicochemicalproperties
AT geraldelisaulo surfaceanalysisofauniversalresincompositeandeffectofpreheatingonitsphysicochemicalproperties
AT sinhoretimarioalexandrecoelho surfaceanalysisofauniversalresincompositeandeffectofpreheatingonitsphysicochemicalproperties