Cargando…
Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique
BACKGROUND: A transjugular intrahepatic portosystemic shunt (TIPS) is widely placed to treat portal hypertension. Because the Viatorr(®) stent (W. L. Gore and Associates, Flagstaff, AZ, United States) is not available in all hospitals in China, the bare metal stent (BMS)/stent-graft combination tech...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642472/ https://www.ncbi.nlm.nih.gov/pubmed/37969720 http://dx.doi.org/10.4240/wjgs.v15.i10.2133 |
_version_ | 1785146976083378176 |
---|---|
author | Liu, Qi-Jia Cao, Xiao-Feng Pei, Yun Li, Xuan Dong, Guo-Xiang Wang, Chang-Ming |
author_facet | Liu, Qi-Jia Cao, Xiao-Feng Pei, Yun Li, Xuan Dong, Guo-Xiang Wang, Chang-Ming |
author_sort | Liu, Qi-Jia |
collection | PubMed |
description | BACKGROUND: A transjugular intrahepatic portosystemic shunt (TIPS) is widely placed to treat portal hypertension. Because the Viatorr(®) stent (W. L. Gore and Associates, Flagstaff, AZ, United States) is not available in all hospitals in China, the bare metal stent (BMS)/stent-graft combination technique is still popular for TIPS construction. Stent fracture is a complication after TIPS placement using this technique, with limited available literature focusing on it. AIM: To assess the incidence of stent fracture after TIPS placement using the BMS/ stent-graft combination technique and to identify the risk factors for stent fracture. We proposed technique modifications to improve the clinical results of TIPS placement with the BMS/stent-graft combination technique. METHODS: We retrospectively analyzed the computed tomography (CT) data of all patients with portal hypertension who underwent the TIPS procedure between June 2011 and December 2021 in a single center. Patients implanted with the BMS/stent graft and had follow-up imaging data available were included. We identified patients with stent fracture and analyzed their characteristics. Multivariable logistic regression was applied to identify the potential predictors of stent fracture. RESULTS: Of the 68 included patients, stent fracture occurred in seven (10.3%) patients. Based on CT images, the stent fractures were categorized into three types. Our study consisted of four (57.1%) type I fractures, one (14.3%) type II fracture, one (14.3%) type IIIa fracture, and one (14.3%) type IIIb fracture. After adjusting for covariates, multivariable logistic regression revealed that the risk factors for stent fracture were the implantation of a greater number of stents [adjusted odds ratio (aOR) = 22.2, 95% confidence interval (CI): 1.2-415.4, P = 0.038] and a larger proximal sagittal stent bending angle (aOR = 1.1, 95%CI: 1.0-1.3, P = 0.020). CONCLUSION: Stent fracture occurred in approximately 10% of patients with portal hypertension who underwent TIPS with the BMS/stent-graft combination technique. The number of implanted stents and stent bending angle at the inferior vena cava end were predictors of stent fracture, which suggests that the incidence of stent fracture could potentially be reduced by procedural modifications. |
format | Online Article Text |
id | pubmed-10642472 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-106424722023-11-15 Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique Liu, Qi-Jia Cao, Xiao-Feng Pei, Yun Li, Xuan Dong, Guo-Xiang Wang, Chang-Ming World J Gastrointest Surg Retrospective Cohort Study BACKGROUND: A transjugular intrahepatic portosystemic shunt (TIPS) is widely placed to treat portal hypertension. Because the Viatorr(®) stent (W. L. Gore and Associates, Flagstaff, AZ, United States) is not available in all hospitals in China, the bare metal stent (BMS)/stent-graft combination technique is still popular for TIPS construction. Stent fracture is a complication after TIPS placement using this technique, with limited available literature focusing on it. AIM: To assess the incidence of stent fracture after TIPS placement using the BMS/ stent-graft combination technique and to identify the risk factors for stent fracture. We proposed technique modifications to improve the clinical results of TIPS placement with the BMS/stent-graft combination technique. METHODS: We retrospectively analyzed the computed tomography (CT) data of all patients with portal hypertension who underwent the TIPS procedure between June 2011 and December 2021 in a single center. Patients implanted with the BMS/stent graft and had follow-up imaging data available were included. We identified patients with stent fracture and analyzed their characteristics. Multivariable logistic regression was applied to identify the potential predictors of stent fracture. RESULTS: Of the 68 included patients, stent fracture occurred in seven (10.3%) patients. Based on CT images, the stent fractures were categorized into three types. Our study consisted of four (57.1%) type I fractures, one (14.3%) type II fracture, one (14.3%) type IIIa fracture, and one (14.3%) type IIIb fracture. After adjusting for covariates, multivariable logistic regression revealed that the risk factors for stent fracture were the implantation of a greater number of stents [adjusted odds ratio (aOR) = 22.2, 95% confidence interval (CI): 1.2-415.4, P = 0.038] and a larger proximal sagittal stent bending angle (aOR = 1.1, 95%CI: 1.0-1.3, P = 0.020). CONCLUSION: Stent fracture occurred in approximately 10% of patients with portal hypertension who underwent TIPS with the BMS/stent-graft combination technique. The number of implanted stents and stent bending angle at the inferior vena cava end were predictors of stent fracture, which suggests that the incidence of stent fracture could potentially be reduced by procedural modifications. Baishideng Publishing Group Inc 2023-10-27 2023-10-27 /pmc/articles/PMC10642472/ /pubmed/37969720 http://dx.doi.org/10.4240/wjgs.v15.i10.2133 Text en ©The Author(s) 2023. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. |
spellingShingle | Retrospective Cohort Study Liu, Qi-Jia Cao, Xiao-Feng Pei, Yun Li, Xuan Dong, Guo-Xiang Wang, Chang-Ming Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique |
title | Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique |
title_full | Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique |
title_fullStr | Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique |
title_full_unstemmed | Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique |
title_short | Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique |
title_sort | stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique |
topic | Retrospective Cohort Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642472/ https://www.ncbi.nlm.nih.gov/pubmed/37969720 http://dx.doi.org/10.4240/wjgs.v15.i10.2133 |
work_keys_str_mv | AT liuqijia stentfractureaftertransjugularintrahepaticportosystemicshuntplacementusingthebaremetalstentstentgraftcombinationtechnique AT caoxiaofeng stentfractureaftertransjugularintrahepaticportosystemicshuntplacementusingthebaremetalstentstentgraftcombinationtechnique AT peiyun stentfractureaftertransjugularintrahepaticportosystemicshuntplacementusingthebaremetalstentstentgraftcombinationtechnique AT lixuan stentfractureaftertransjugularintrahepaticportosystemicshuntplacementusingthebaremetalstentstentgraftcombinationtechnique AT dongguoxiang stentfractureaftertransjugularintrahepaticportosystemicshuntplacementusingthebaremetalstentstentgraftcombinationtechnique AT wangchangming stentfractureaftertransjugularintrahepaticportosystemicshuntplacementusingthebaremetalstentstentgraftcombinationtechnique |