Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy

PURPOSE: The focus of this work was given on the relative stopping power (RSP) using the water equivalent thickness (WET) validation on tissue substitutes and real pig organs, as well as a dosimetric comparison of proton treatment plans between single-energy computed tomography (SECT) and dual-energ...

Descripción completa

Detalles Bibliográficos
Autores principales: Chirdchid, Thamonwan, Ruangchan, Sirinya, Sanghangthum, Taweap
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642597/
https://www.ncbi.nlm.nih.gov/pubmed/37969143
http://dx.doi.org/10.4103/jmp.jmp_27_23
_version_ 1785146997852864512
author Chirdchid, Thamonwan
Ruangchan, Sirinya
Sanghangthum, Taweap
author_facet Chirdchid, Thamonwan
Ruangchan, Sirinya
Sanghangthum, Taweap
author_sort Chirdchid, Thamonwan
collection PubMed
description PURPOSE: The focus of this work was given on the relative stopping power (RSP) using the water equivalent thickness (WET) validation on tissue substitutes and real pig organs, as well as a dosimetric comparison of proton treatment plans between single-energy computed tomography (SECT) and dual-energy computed tomography (DECT)-based dose calculations. MATERIALS AND METHODS: The CT calibration curve of SECT and DECT data was generated using the stoichiometric calibration method. WET measurement was performed for RSP validation using a Giraffe dosimeter (IBA dosimetry) in various substitute tissues (Gammex) and real pig tissues. The thorax (008A, CIRS) and head (731-HN, CIRS) phantoms were used to generate proton plans. The dosimetric evaluations of SECT and DECT-based plans were performed using the gamma analysis with 1%/1 mm and the dose–volume histograms (DVHs) comparison. RESULTS: For RSP validation of substitute tissues, the largest percent WET difference between measurement and calculation was observed up to 17.9% (4 mm) in lung tissue, using SECT based. In real pig tissues, the average WET difference was 2.3% ± 2.1% and 2.5% ± 2.3% for SECT and DECT, respectively. The average gamma passed of about 92.1% for the lung and 96.8% for the head regions was reported. For the lung region, the DVH of the target dose was observed with a higher predicted dose in SECT than in DECT, while results in the head region were in good agreement for both SECT and DECT. CONCLUSION: The performed dosimetric comparison indicates the dose differences between SECT and DECT. The impact of the CT calibration curve is more pronounced for the thorax region.
format Online
Article
Text
id pubmed-10642597
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-106425972023-11-15 Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy Chirdchid, Thamonwan Ruangchan, Sirinya Sanghangthum, Taweap J Med Phys Original Article PURPOSE: The focus of this work was given on the relative stopping power (RSP) using the water equivalent thickness (WET) validation on tissue substitutes and real pig organs, as well as a dosimetric comparison of proton treatment plans between single-energy computed tomography (SECT) and dual-energy computed tomography (DECT)-based dose calculations. MATERIALS AND METHODS: The CT calibration curve of SECT and DECT data was generated using the stoichiometric calibration method. WET measurement was performed for RSP validation using a Giraffe dosimeter (IBA dosimetry) in various substitute tissues (Gammex) and real pig tissues. The thorax (008A, CIRS) and head (731-HN, CIRS) phantoms were used to generate proton plans. The dosimetric evaluations of SECT and DECT-based plans were performed using the gamma analysis with 1%/1 mm and the dose–volume histograms (DVHs) comparison. RESULTS: For RSP validation of substitute tissues, the largest percent WET difference between measurement and calculation was observed up to 17.9% (4 mm) in lung tissue, using SECT based. In real pig tissues, the average WET difference was 2.3% ± 2.1% and 2.5% ± 2.3% for SECT and DECT, respectively. The average gamma passed of about 92.1% for the lung and 96.8% for the head regions was reported. For the lung region, the DVH of the target dose was observed with a higher predicted dose in SECT than in DECT, while results in the head region were in good agreement for both SECT and DECT. CONCLUSION: The performed dosimetric comparison indicates the dose differences between SECT and DECT. The impact of the CT calibration curve is more pronounced for the thorax region. Wolters Kluwer - Medknow 2023 2023-09-18 /pmc/articles/PMC10642597/ /pubmed/37969143 http://dx.doi.org/10.4103/jmp.jmp_27_23 Text en Copyright: © 2023 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Chirdchid, Thamonwan
Ruangchan, Sirinya
Sanghangthum, Taweap
Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy
title Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy
title_full Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy
title_fullStr Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy
title_full_unstemmed Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy
title_short Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy
title_sort dosimetric comparison between single-energy computed tomography and dual-energy computed tomography relative to stopping power estimation in proton therapy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642597/
https://www.ncbi.nlm.nih.gov/pubmed/37969143
http://dx.doi.org/10.4103/jmp.jmp_27_23
work_keys_str_mv AT chirdchidthamonwan dosimetriccomparisonbetweensingleenergycomputedtomographyanddualenergycomputedtomographyrelativetostoppingpowerestimationinprotontherapy
AT ruangchansirinya dosimetriccomparisonbetweensingleenergycomputedtomographyanddualenergycomputedtomographyrelativetostoppingpowerestimationinprotontherapy
AT sanghangthumtaweap dosimetriccomparisonbetweensingleenergycomputedtomographyanddualenergycomputedtomographyrelativetostoppingpowerestimationinprotontherapy