Evaluation of International Atomic Energy Agency Technical Report Series-483 Detector-specific Output Correction Factor for Various Collimator Systems
AIM: In this study, a 6MV flattening filter (FF) and 6MV FF Free (FFF) photon beam small-field output factors (OF) were measured with various collimators using different detectors. The corrected OFs were compared with the treatment planning system (TPS) calculated OFs. MATERIALS AND METHODS: OF meas...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642599/ https://www.ncbi.nlm.nih.gov/pubmed/37969152 http://dx.doi.org/10.4103/jmp.jmp_59_23 |
_version_ | 1785146998322626560 |
---|---|
author | Kannan, Mageshraja Saminathan, Sathiyan Chandraraj, Varatharaj Raj, D. Gowtham Ganesh, K. M. |
author_facet | Kannan, Mageshraja Saminathan, Sathiyan Chandraraj, Varatharaj Raj, D. Gowtham Ganesh, K. M. |
author_sort | Kannan, Mageshraja |
collection | PubMed |
description | AIM: In this study, a 6MV flattening filter (FF) and 6MV FF Free (FFF) photon beam small-field output factors (OF) were measured with various collimators using different detectors. The corrected OFs were compared with the treatment planning system (TPS) calculated OFs. MATERIALS AND METHODS: OF measurements were performed with four different types of collimators: Varian Millennium multi-leaf collimator (MLC), Elekta Agility MLC, Apex micro-MLC (mMLC) and a stereotactic cone. Ten detectors (four ionization chambers and six diodes) were used to perform the OF measurements at a depth of 10 cm with a source-to-surface distance of 90 cm. The corrected OF was calculated from the measurements. The corrected OFs were compared with existing TPS-generated OFs. RESULTS: The use of detector-specific output correction factor (OCF) in the PTW diode P detector reduced the OF uncertainty by <4.1% for 1 cm × 1 cm S(clin). The corrected OF was compared with TPS calculated OF; the maximum variation with the IBA CC01 chamber was 3.75%, 3.72%, 1.16%, and 0.90% for 5 mm stereotactic cone, 0.49 cm × 0.49 cm Apex mMLC, 1 cm × 1 cm Agility MLC, and 1 cm × 1 cm Millennium MLC, respectively. CONCLUSION: The technical report series-483 protocol recommends that detector-specific OCF should be used to calculate the corrected OF from the measured OF. The implementation of OCF in the TPS commissioning will reduce the small-field OF variation by <3% for any type of detector. |
format | Online Article Text |
id | pubmed-10642599 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-106425992023-11-15 Evaluation of International Atomic Energy Agency Technical Report Series-483 Detector-specific Output Correction Factor for Various Collimator Systems Kannan, Mageshraja Saminathan, Sathiyan Chandraraj, Varatharaj Raj, D. Gowtham Ganesh, K. M. J Med Phys Original Article AIM: In this study, a 6MV flattening filter (FF) and 6MV FF Free (FFF) photon beam small-field output factors (OF) were measured with various collimators using different detectors. The corrected OFs were compared with the treatment planning system (TPS) calculated OFs. MATERIALS AND METHODS: OF measurements were performed with four different types of collimators: Varian Millennium multi-leaf collimator (MLC), Elekta Agility MLC, Apex micro-MLC (mMLC) and a stereotactic cone. Ten detectors (four ionization chambers and six diodes) were used to perform the OF measurements at a depth of 10 cm with a source-to-surface distance of 90 cm. The corrected OF was calculated from the measurements. The corrected OFs were compared with existing TPS-generated OFs. RESULTS: The use of detector-specific output correction factor (OCF) in the PTW diode P detector reduced the OF uncertainty by <4.1% for 1 cm × 1 cm S(clin). The corrected OF was compared with TPS calculated OF; the maximum variation with the IBA CC01 chamber was 3.75%, 3.72%, 1.16%, and 0.90% for 5 mm stereotactic cone, 0.49 cm × 0.49 cm Apex mMLC, 1 cm × 1 cm Agility MLC, and 1 cm × 1 cm Millennium MLC, respectively. CONCLUSION: The technical report series-483 protocol recommends that detector-specific OCF should be used to calculate the corrected OF from the measured OF. The implementation of OCF in the TPS commissioning will reduce the small-field OF variation by <3% for any type of detector. Wolters Kluwer - Medknow 2023 2023-09-18 /pmc/articles/PMC10642599/ /pubmed/37969152 http://dx.doi.org/10.4103/jmp.jmp_59_23 Text en Copyright: © 2023 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Kannan, Mageshraja Saminathan, Sathiyan Chandraraj, Varatharaj Raj, D. Gowtham Ganesh, K. M. Evaluation of International Atomic Energy Agency Technical Report Series-483 Detector-specific Output Correction Factor for Various Collimator Systems |
title | Evaluation of International Atomic Energy Agency Technical Report Series-483 Detector-specific Output Correction Factor for Various Collimator Systems |
title_full | Evaluation of International Atomic Energy Agency Technical Report Series-483 Detector-specific Output Correction Factor for Various Collimator Systems |
title_fullStr | Evaluation of International Atomic Energy Agency Technical Report Series-483 Detector-specific Output Correction Factor for Various Collimator Systems |
title_full_unstemmed | Evaluation of International Atomic Energy Agency Technical Report Series-483 Detector-specific Output Correction Factor for Various Collimator Systems |
title_short | Evaluation of International Atomic Energy Agency Technical Report Series-483 Detector-specific Output Correction Factor for Various Collimator Systems |
title_sort | evaluation of international atomic energy agency technical report series-483 detector-specific output correction factor for various collimator systems |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642599/ https://www.ncbi.nlm.nih.gov/pubmed/37969152 http://dx.doi.org/10.4103/jmp.jmp_59_23 |
work_keys_str_mv | AT kannanmageshraja evaluationofinternationalatomicenergyagencytechnicalreportseries483detectorspecificoutputcorrectionfactorforvariouscollimatorsystems AT saminathansathiyan evaluationofinternationalatomicenergyagencytechnicalreportseries483detectorspecificoutputcorrectionfactorforvariouscollimatorsystems AT chandrarajvaratharaj evaluationofinternationalatomicenergyagencytechnicalreportseries483detectorspecificoutputcorrectionfactorforvariouscollimatorsystems AT rajdgowtham evaluationofinternationalatomicenergyagencytechnicalreportseries483detectorspecificoutputcorrectionfactorforvariouscollimatorsystems AT ganeshkm evaluationofinternationalatomicenergyagencytechnicalreportseries483detectorspecificoutputcorrectionfactorforvariouscollimatorsystems |