Cargando…

Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes

BACKGROUND: Aim of the study was to compare success rate and functional outcome following pars plana vitrectomy (PPV) with conventional internal limiting membrane (ILM) peeling versus ILM flap technique for full-thickness idiopathic macular holes (FTMH). METHODS: Retrospective analysis of consecutiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Dera, Adrianna U., Stoll, Doerte, Schoeneberger, Verena, Walckling, Marcus, Brockmann, Claudia, Fuchsluger, Thomas A., Schaub, Friederike
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10644592/
https://www.ncbi.nlm.nih.gov/pubmed/37964333
http://dx.doi.org/10.1186/s40942-023-00509-1
_version_ 1785147261487939584
author Dera, Adrianna U.
Stoll, Doerte
Schoeneberger, Verena
Walckling, Marcus
Brockmann, Claudia
Fuchsluger, Thomas A.
Schaub, Friederike
author_facet Dera, Adrianna U.
Stoll, Doerte
Schoeneberger, Verena
Walckling, Marcus
Brockmann, Claudia
Fuchsluger, Thomas A.
Schaub, Friederike
author_sort Dera, Adrianna U.
collection PubMed
description BACKGROUND: Aim of the study was to compare success rate and functional outcome following pars plana vitrectomy (PPV) with conventional internal limiting membrane (ILM) peeling versus ILM flap technique for full-thickness idiopathic macular holes (FTMH). METHODS: Retrospective analysis of consecutive eyes with FTMH having undergone vitrectomy with sulfur hexafluoride (SF6) endotamponade 25% at the University Medical Center Rostock, Germany (2009–2020). Eyes were divided according to applied surgical technique (ILM peeling [group P] versus ILM flap [group F]). Inclusion criteria were macular hole base diameters (MH-BD) ≥ 400 μm plus axial length ≤ 26.0 mm. Each group was divided into two subgroups based on macular hole minimum linear diameter (MH-MLD): ≤ 400 μm and > 400 μm. Exclusion criteria were FTMH with MH-BD < 400 μm, trauma, myopia with axial length > 26.0 mm or macular schisis. Demographic, functional, and anatomical data were obtained pre- and postoperatively. Preoperative MH-BD and MH-MLD were measured using optical coherence tomography (OCT; Spectralis®, Heidelberg Engineering GmbH, Heidelberg, Germany). Main outcome parameter were: primary closure rate, best-corrected visual acuity (BCVA), and re-surgery rate. RESULTS: Overall 117 eyes of 117 patients with FTMH could be included, thereof 52 eyes underwent conventional ILM peeling (group P) and 65 additional ILM flap (group F) technique. Macular hole closure was achieved in 31 eyes (59.6%) in group P and in 59 eyes (90.8%) in group F (p < 0.001). Secondary PPV was required in 21 eyes (40.4%) in group P and in 6 eyes (9.2%) in group F. Postoperative BCVA at first follow-up in eyes with surgical closure showed no significant difference for both groups (MH-MLD ≤ 400 μm: p = 0.740); MH-MLD > 400 μm: p = 0.241). CONCLUSION: Anatomical results and surgical closure rate following ILM flap technique seems to be superior to conventional ILM peeling for treatment of FTMH.
format Online
Article
Text
id pubmed-10644592
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-106445922023-11-14 Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes Dera, Adrianna U. Stoll, Doerte Schoeneberger, Verena Walckling, Marcus Brockmann, Claudia Fuchsluger, Thomas A. Schaub, Friederike Int J Retina Vitreous Original Article BACKGROUND: Aim of the study was to compare success rate and functional outcome following pars plana vitrectomy (PPV) with conventional internal limiting membrane (ILM) peeling versus ILM flap technique for full-thickness idiopathic macular holes (FTMH). METHODS: Retrospective analysis of consecutive eyes with FTMH having undergone vitrectomy with sulfur hexafluoride (SF6) endotamponade 25% at the University Medical Center Rostock, Germany (2009–2020). Eyes were divided according to applied surgical technique (ILM peeling [group P] versus ILM flap [group F]). Inclusion criteria were macular hole base diameters (MH-BD) ≥ 400 μm plus axial length ≤ 26.0 mm. Each group was divided into two subgroups based on macular hole minimum linear diameter (MH-MLD): ≤ 400 μm and > 400 μm. Exclusion criteria were FTMH with MH-BD < 400 μm, trauma, myopia with axial length > 26.0 mm or macular schisis. Demographic, functional, and anatomical data were obtained pre- and postoperatively. Preoperative MH-BD and MH-MLD were measured using optical coherence tomography (OCT; Spectralis®, Heidelberg Engineering GmbH, Heidelberg, Germany). Main outcome parameter were: primary closure rate, best-corrected visual acuity (BCVA), and re-surgery rate. RESULTS: Overall 117 eyes of 117 patients with FTMH could be included, thereof 52 eyes underwent conventional ILM peeling (group P) and 65 additional ILM flap (group F) technique. Macular hole closure was achieved in 31 eyes (59.6%) in group P and in 59 eyes (90.8%) in group F (p < 0.001). Secondary PPV was required in 21 eyes (40.4%) in group P and in 6 eyes (9.2%) in group F. Postoperative BCVA at first follow-up in eyes with surgical closure showed no significant difference for both groups (MH-MLD ≤ 400 μm: p = 0.740); MH-MLD > 400 μm: p = 0.241). CONCLUSION: Anatomical results and surgical closure rate following ILM flap technique seems to be superior to conventional ILM peeling for treatment of FTMH. BioMed Central 2023-11-14 /pmc/articles/PMC10644592/ /pubmed/37964333 http://dx.doi.org/10.1186/s40942-023-00509-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Original Article
Dera, Adrianna U.
Stoll, Doerte
Schoeneberger, Verena
Walckling, Marcus
Brockmann, Claudia
Fuchsluger, Thomas A.
Schaub, Friederike
Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes
title Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes
title_full Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes
title_fullStr Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes
title_full_unstemmed Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes
title_short Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes
title_sort anatomical and functional results after vitrectomy with conventional ilm peeling versus inverted ilm flap technique in large full-thickness macular holes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10644592/
https://www.ncbi.nlm.nih.gov/pubmed/37964333
http://dx.doi.org/10.1186/s40942-023-00509-1
work_keys_str_mv AT deraadriannau anatomicalandfunctionalresultsaftervitrectomywithconventionalilmpeelingversusinvertedilmflaptechniqueinlargefullthicknessmacularholes
AT stolldoerte anatomicalandfunctionalresultsaftervitrectomywithconventionalilmpeelingversusinvertedilmflaptechniqueinlargefullthicknessmacularholes
AT schoenebergerverena anatomicalandfunctionalresultsaftervitrectomywithconventionalilmpeelingversusinvertedilmflaptechniqueinlargefullthicknessmacularholes
AT walcklingmarcus anatomicalandfunctionalresultsaftervitrectomywithconventionalilmpeelingversusinvertedilmflaptechniqueinlargefullthicknessmacularholes
AT brockmannclaudia anatomicalandfunctionalresultsaftervitrectomywithconventionalilmpeelingversusinvertedilmflaptechniqueinlargefullthicknessmacularholes
AT fuchslugerthomasa anatomicalandfunctionalresultsaftervitrectomywithconventionalilmpeelingversusinvertedilmflaptechniqueinlargefullthicknessmacularholes
AT schaubfriederike anatomicalandfunctionalresultsaftervitrectomywithconventionalilmpeelingversusinvertedilmflaptechniqueinlargefullthicknessmacularholes