Cargando…
Continuous Vertical Inside-Out Versus Traditional Vertical Inside-Out Meniscal Repair: A Biomechanical Comparison
BACKGROUND: Biomechanical assessment of meniscal repairs is essential for evaluating different meniscal suturing methods and techniques. The continuous meniscal suture technique is a newer method of meniscal repair that may have biomechanical differences compared with traditional techniques. PURPOSE...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10644761/ https://www.ncbi.nlm.nih.gov/pubmed/38021309 http://dx.doi.org/10.1177/23259671231209951 |
Sumario: | BACKGROUND: Biomechanical assessment of meniscal repairs is essential for evaluating different meniscal suturing methods and techniques. The continuous meniscal suture technique is a newer method of meniscal repair that may have biomechanical differences compared with traditional techniques. PURPOSE: To evaluate the displacement, stiffness after cyclical loading, and load to failure for a continuous vertical inside-out meniscal suture versus a traditional vertical inside-out meniscal suture in a porcine medial meniscus. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 28 porcine knees were acquired and divided into 2 test groups of 14 medial meniscus each. A 2.0-cm longitudinal red-white zone cut was made in the body of the medial meniscus for each knee. The continuous suture (CS) group received 4 vertical stitches performed with a continuous vertical meniscal suture technique, and the inside-out suture (IO) group received a traditional vertical suture with 4 stitches. Two traction tapes were passed between the sutures and positioned in the biomechanical testing fixture device. Each specimen underwent load-to-failure testing at 5 mm/s, and displacement, system stiffness, and maximum load to failure were compared between the groups. RESULTS: The displacement after the cyclic test was 0.53 ± 0.12 and 0.48 ± 0.07 mm for the CS and IO groups, respectively. There was no significant difference between the groups (P = .2792). The stiffness at the ultimate load testing was 36.3 ± 1.9 and 35.3 ± 2.4 N/mm for groups CS and IO, respectively, with no significant difference between the groups (P = .2557). In the load-to-failure test, the ultimate load was 218.2 ± 63.9 and 238.3 ± 71.3 N in the CS and IO groups, respectively, with no significant group differences (P = .3062). CONCLUSION: A continuous vertical meniscal suture created a configuration for treating longitudinal meniscal lesions that was beneficial and biomechanically similar to a traditional vertical suture technique. CLINICAL RELEVANCE: The study findings indicate that use of the continuous vertical inside-out meniscal suture technique is a possible therapeutic option. |
---|