Cargando…
An automatic pipeline for PET/MRI attenuation correction validation in the brain
PURPOSE: Challenges in PET/MRI quantitative accuracy for neurological uses arise from PET attenuation correction accuracy. We proposed and evaluated an automatic pipeline to assess the quantitative accuracy of four MRI-derived PET AC methods using analytically simulated PET brain lesions and ROIs as...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10645915/ https://www.ncbi.nlm.nih.gov/pubmed/37962707 http://dx.doi.org/10.1186/s40658-023-00590-3 |
_version_ | 1785147418371686400 |
---|---|
author | Hamdi, Mahdjoub Ying, Chunwei An, Hongyu Laforest, Richard |
author_facet | Hamdi, Mahdjoub Ying, Chunwei An, Hongyu Laforest, Richard |
author_sort | Hamdi, Mahdjoub |
collection | PubMed |
description | PURPOSE: Challenges in PET/MRI quantitative accuracy for neurological uses arise from PET attenuation correction accuracy. We proposed and evaluated an automatic pipeline to assess the quantitative accuracy of four MRI-derived PET AC methods using analytically simulated PET brain lesions and ROIs as ground truth for PET activity. METHODS: Our proposed pipeline, integrating a synthetic lesion insertion tool and the FreeSurfer neuroimaging framework, inserts simulated spherical and brain ROIs into PET projection space, reconstructing them via four PET MRAC techniques. Utilizing an 11-patient brain PET dataset, we compared the quantitative accuracy of four MRACs (DIXON, DIXONbone, UTE AC, and DL-DIXON) against the gold standard PET CTAC, evaluating MRAC to CTAC activity bias in spherical lesions and brain ROIs with and without background activity against original (lesion free) PET reconstructed images. RESULTS: The proposed pipeline yielded accurate results for spherical lesions and brain ROIs, adhering to the MRAC to CTAC pattern of original brain PET images. Among the MRAC methods, DIXON AC exhibited the highest bias, followed by UTE, DIXONBone, and DL-DIXON showing the least. DIXON, DIXONbone, UTE, and DL-DIXON showed MRAC to CTAC biases of − 5.41%, − 1.85%, − 2.74%, and 0.08% respectively for ROIs inserted in background activity; − 7.02%, − 2.46%, − 3.56%, and − 0.05% for lesion ROIs without background; and − 6.82%, − 2.08%, − 2.29%, and 0.22% for the original brain PET images’ 16 FreeSurfer brain ROIs. CONCLUSION: The proposed pipeline delivers accurate results for synthetic spherical lesions and brain ROIs, with and without background activity consideration, enabling the evaluation of new attenuation correction approaches without utilizing measured PET emission data. Additionally, it offers a consistent method to generate realistic lesion ROIs, potentially applicable in assessing further PET correction techniques. |
format | Online Article Text |
id | pubmed-10645915 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-106459152023-11-14 An automatic pipeline for PET/MRI attenuation correction validation in the brain Hamdi, Mahdjoub Ying, Chunwei An, Hongyu Laforest, Richard EJNMMI Phys Original Research PURPOSE: Challenges in PET/MRI quantitative accuracy for neurological uses arise from PET attenuation correction accuracy. We proposed and evaluated an automatic pipeline to assess the quantitative accuracy of four MRI-derived PET AC methods using analytically simulated PET brain lesions and ROIs as ground truth for PET activity. METHODS: Our proposed pipeline, integrating a synthetic lesion insertion tool and the FreeSurfer neuroimaging framework, inserts simulated spherical and brain ROIs into PET projection space, reconstructing them via four PET MRAC techniques. Utilizing an 11-patient brain PET dataset, we compared the quantitative accuracy of four MRACs (DIXON, DIXONbone, UTE AC, and DL-DIXON) against the gold standard PET CTAC, evaluating MRAC to CTAC activity bias in spherical lesions and brain ROIs with and without background activity against original (lesion free) PET reconstructed images. RESULTS: The proposed pipeline yielded accurate results for spherical lesions and brain ROIs, adhering to the MRAC to CTAC pattern of original brain PET images. Among the MRAC methods, DIXON AC exhibited the highest bias, followed by UTE, DIXONBone, and DL-DIXON showing the least. DIXON, DIXONbone, UTE, and DL-DIXON showed MRAC to CTAC biases of − 5.41%, − 1.85%, − 2.74%, and 0.08% respectively for ROIs inserted in background activity; − 7.02%, − 2.46%, − 3.56%, and − 0.05% for lesion ROIs without background; and − 6.82%, − 2.08%, − 2.29%, and 0.22% for the original brain PET images’ 16 FreeSurfer brain ROIs. CONCLUSION: The proposed pipeline delivers accurate results for synthetic spherical lesions and brain ROIs, with and without background activity consideration, enabling the evaluation of new attenuation correction approaches without utilizing measured PET emission data. Additionally, it offers a consistent method to generate realistic lesion ROIs, potentially applicable in assessing further PET correction techniques. Springer International Publishing 2023-11-14 /pmc/articles/PMC10645915/ /pubmed/37962707 http://dx.doi.org/10.1186/s40658-023-00590-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Research Hamdi, Mahdjoub Ying, Chunwei An, Hongyu Laforest, Richard An automatic pipeline for PET/MRI attenuation correction validation in the brain |
title | An automatic pipeline for PET/MRI attenuation correction validation in the brain |
title_full | An automatic pipeline for PET/MRI attenuation correction validation in the brain |
title_fullStr | An automatic pipeline for PET/MRI attenuation correction validation in the brain |
title_full_unstemmed | An automatic pipeline for PET/MRI attenuation correction validation in the brain |
title_short | An automatic pipeline for PET/MRI attenuation correction validation in the brain |
title_sort | automatic pipeline for pet/mri attenuation correction validation in the brain |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10645915/ https://www.ncbi.nlm.nih.gov/pubmed/37962707 http://dx.doi.org/10.1186/s40658-023-00590-3 |
work_keys_str_mv | AT hamdimahdjoub anautomaticpipelineforpetmriattenuationcorrectionvalidationinthebrain AT yingchunwei anautomaticpipelineforpetmriattenuationcorrectionvalidationinthebrain AT anhongyu anautomaticpipelineforpetmriattenuationcorrectionvalidationinthebrain AT laforestrichard anautomaticpipelineforpetmriattenuationcorrectionvalidationinthebrain AT hamdimahdjoub automaticpipelineforpetmriattenuationcorrectionvalidationinthebrain AT yingchunwei automaticpipelineforpetmriattenuationcorrectionvalidationinthebrain AT anhongyu automaticpipelineforpetmriattenuationcorrectionvalidationinthebrain AT laforestrichard automaticpipelineforpetmriattenuationcorrectionvalidationinthebrain |