Cargando…

Safe surgical corridor for iliosacral screw placement in unstable pelvic fractures: a computed-tomography-guided validation study of the “triangulation method”

BACKGROUND: The percutaneous iliosacral screw technique represents a global standard fixation method for unstable fractures of the posterior pelvic ring. However, the inaccurate positioning of iliosacral screws is associated with a significant risk of severe intra-operative complications. Therefore,...

Descripción completa

Detalles Bibliográficos
Autores principales: ZHENG, Yu-Bo, ZHAO, Xin, ZHENG, Qiang, SANG, Xi-Guang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10647156/
https://www.ncbi.nlm.nih.gov/pubmed/37968701
http://dx.doi.org/10.1186/s13037-023-00380-x
_version_ 1785147513512132608
author ZHENG, Yu-Bo
ZHAO, Xin
ZHENG, Qiang
SANG, Xi-Guang
author_facet ZHENG, Yu-Bo
ZHAO, Xin
ZHENG, Qiang
SANG, Xi-Guang
author_sort ZHENG, Yu-Bo
collection PubMed
description BACKGROUND: The percutaneous iliosacral screw technique represents a global standard fixation method for unstable fractures of the posterior pelvic ring. However, the inaccurate positioning of iliosacral screws is associated with a significant risk of severe intra-operative complications. Therefore, this study aimed to investigate the relationship between the skin entry point of the transverse iliosacral screw of the first sacral vertebral body and the anterior superior iliac spine and the greater trochanter of the femur using computed-tomography-guided validation. METHODS: Overall, 91 consecutive patients admitted to a tertiary referral center in China for posterior pelvic ring fixation via the “triangulation method” using computed-tomography-guided validation between January 1, 2020, and December 31, 2020, were included in this retrospective observational cohort study. Modeling and simulated iliosacral screw placement were performed using the Mimics software. The distance between the three points of interest was measured, and their relationship in a rectangular coordinate system was determined. Patients were categorized according to gender, body mass index, and femoral rotation angle to investigate the factors affecting the positional relationship between the three points. RESULTS: An equilateral triangular relationship was observed between the positioning points of the transverse iliosacral screw, anterior iliac spine, and greater trochanter. Additionally, 95% of the entry points were within a circle radius centered 12 mm at the apex of an equilateral triangle comprising the anterior superior iliac spine and the greater trochanter as the base. The entry point in the femoral external rotation was more dorsal than that in the internal femoral rotation. Furthermore, the entry point in females was more rostral than that in males, and the entry point in overweight patients was more dorsal than that in normal-weight patients. CONCLUSIONS: The skin entry point of the percutaneous iliosacral screw can be located by drawing an equilateral triangle from the anterior superior iliac spine and the greater trochanter as the base to the dorsum end of the patient’s head. In summary, this retrospective cohort study validated the safety and efficacy of the “triangulation methods” for percutaneous fixation of unstable posterior pelvic ring injuries.
format Online
Article
Text
id pubmed-10647156
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-106471562023-11-15 Safe surgical corridor for iliosacral screw placement in unstable pelvic fractures: a computed-tomography-guided validation study of the “triangulation method” ZHENG, Yu-Bo ZHAO, Xin ZHENG, Qiang SANG, Xi-Guang Patient Saf Surg Research BACKGROUND: The percutaneous iliosacral screw technique represents a global standard fixation method for unstable fractures of the posterior pelvic ring. However, the inaccurate positioning of iliosacral screws is associated with a significant risk of severe intra-operative complications. Therefore, this study aimed to investigate the relationship between the skin entry point of the transverse iliosacral screw of the first sacral vertebral body and the anterior superior iliac spine and the greater trochanter of the femur using computed-tomography-guided validation. METHODS: Overall, 91 consecutive patients admitted to a tertiary referral center in China for posterior pelvic ring fixation via the “triangulation method” using computed-tomography-guided validation between January 1, 2020, and December 31, 2020, were included in this retrospective observational cohort study. Modeling and simulated iliosacral screw placement were performed using the Mimics software. The distance between the three points of interest was measured, and their relationship in a rectangular coordinate system was determined. Patients were categorized according to gender, body mass index, and femoral rotation angle to investigate the factors affecting the positional relationship between the three points. RESULTS: An equilateral triangular relationship was observed between the positioning points of the transverse iliosacral screw, anterior iliac spine, and greater trochanter. Additionally, 95% of the entry points were within a circle radius centered 12 mm at the apex of an equilateral triangle comprising the anterior superior iliac spine and the greater trochanter as the base. The entry point in the femoral external rotation was more dorsal than that in the internal femoral rotation. Furthermore, the entry point in females was more rostral than that in males, and the entry point in overweight patients was more dorsal than that in normal-weight patients. CONCLUSIONS: The skin entry point of the percutaneous iliosacral screw can be located by drawing an equilateral triangle from the anterior superior iliac spine and the greater trochanter as the base to the dorsum end of the patient’s head. In summary, this retrospective cohort study validated the safety and efficacy of the “triangulation methods” for percutaneous fixation of unstable posterior pelvic ring injuries. BioMed Central 2023-11-15 /pmc/articles/PMC10647156/ /pubmed/37968701 http://dx.doi.org/10.1186/s13037-023-00380-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
ZHENG, Yu-Bo
ZHAO, Xin
ZHENG, Qiang
SANG, Xi-Guang
Safe surgical corridor for iliosacral screw placement in unstable pelvic fractures: a computed-tomography-guided validation study of the “triangulation method”
title Safe surgical corridor for iliosacral screw placement in unstable pelvic fractures: a computed-tomography-guided validation study of the “triangulation method”
title_full Safe surgical corridor for iliosacral screw placement in unstable pelvic fractures: a computed-tomography-guided validation study of the “triangulation method”
title_fullStr Safe surgical corridor for iliosacral screw placement in unstable pelvic fractures: a computed-tomography-guided validation study of the “triangulation method”
title_full_unstemmed Safe surgical corridor for iliosacral screw placement in unstable pelvic fractures: a computed-tomography-guided validation study of the “triangulation method”
title_short Safe surgical corridor for iliosacral screw placement in unstable pelvic fractures: a computed-tomography-guided validation study of the “triangulation method”
title_sort safe surgical corridor for iliosacral screw placement in unstable pelvic fractures: a computed-tomography-guided validation study of the “triangulation method”
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10647156/
https://www.ncbi.nlm.nih.gov/pubmed/37968701
http://dx.doi.org/10.1186/s13037-023-00380-x
work_keys_str_mv AT zhengyubo safesurgicalcorridorforiliosacralscrewplacementinunstablepelvicfracturesacomputedtomographyguidedvalidationstudyofthetriangulationmethod
AT zhaoxin safesurgicalcorridorforiliosacralscrewplacementinunstablepelvicfracturesacomputedtomographyguidedvalidationstudyofthetriangulationmethod
AT zhengqiang safesurgicalcorridorforiliosacralscrewplacementinunstablepelvicfracturesacomputedtomographyguidedvalidationstudyofthetriangulationmethod
AT sangxiguang safesurgicalcorridorforiliosacralscrewplacementinunstablepelvicfracturesacomputedtomographyguidedvalidationstudyofthetriangulationmethod