Design and Finite Element Simulation of a Novel 3D-CMUT Device for Simultaneous Sensing of In-Plane and Out-of-Plane Displacements of Ultrasonic Guided Waves

In this study, we introduce a physical model of a three-dimensional (3D) guided wave sensor called 3D-CMUT, which is based on capacitive micro-machined ultrasonic transducers (CMUTs). This 3D-CMUT sensor is designed to effectively and simultaneously obtain 3D vibration information about ultrasonic g...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Sai, Lu, Wei, Wang, Ailing, Hao, Guodong, Wang, Renxing, Yilmaz, Mehmet
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10647637/
https://www.ncbi.nlm.nih.gov/pubmed/37960406
http://dx.doi.org/10.3390/s23218706
_version_ 1785135153875517440
author Zhang, Sai
Lu, Wei
Wang, Ailing
Hao, Guodong
Wang, Renxing
Yilmaz, Mehmet
author_facet Zhang, Sai
Lu, Wei
Wang, Ailing
Hao, Guodong
Wang, Renxing
Yilmaz, Mehmet
author_sort Zhang, Sai
collection PubMed
description In this study, we introduce a physical model of a three-dimensional (3D) guided wave sensor called 3D-CMUT, which is based on capacitive micro-machined ultrasonic transducers (CMUTs). This 3D-CMUT sensor is designed to effectively and simultaneously obtain 3D vibration information about ultrasonic guided waves in the out-of-plane (z-direction) and in-plane (x and y-directions). The basic unit of the 3D-CMUT is much smaller than the wavelength of the guided waves and consists of two orthogonal comb-like CMUT cells and one piston-type CMUT cell. These cells are used to sense displacement signals in the x, y, and z-directions. To ensure proper functioning of the 3D-CMUT unit, the resonant frequencies of the three composed cells are set to be identical by adjusting the microstructural parameters appropriately. Moreover, the same sensitivity in the x, y, and z-directions is theoretically achieved by tuning the amplification parameters in the external circuit. We establish a transient analysis model of the 3D-CMUT using COMSOL finite element simulation software to confirm its ability to sense multimode ultrasonic guided waves, including A(0), S(0), and SH(0) modes. Additionally, we simulate the ball drop impact acoustic emission signal on a plate to demonstrate that the 3D-CMUT can not only utilize in-plane information for positioning but also out-of-plane information. The proposed 3D-CMUT holds significant potential for applications in the field of structural health monitoring (SHM).
format Online
Article
Text
id pubmed-10647637
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106476372023-10-25 Design and Finite Element Simulation of a Novel 3D-CMUT Device for Simultaneous Sensing of In-Plane and Out-of-Plane Displacements of Ultrasonic Guided Waves Zhang, Sai Lu, Wei Wang, Ailing Hao, Guodong Wang, Renxing Yilmaz, Mehmet Sensors (Basel) Article In this study, we introduce a physical model of a three-dimensional (3D) guided wave sensor called 3D-CMUT, which is based on capacitive micro-machined ultrasonic transducers (CMUTs). This 3D-CMUT sensor is designed to effectively and simultaneously obtain 3D vibration information about ultrasonic guided waves in the out-of-plane (z-direction) and in-plane (x and y-directions). The basic unit of the 3D-CMUT is much smaller than the wavelength of the guided waves and consists of two orthogonal comb-like CMUT cells and one piston-type CMUT cell. These cells are used to sense displacement signals in the x, y, and z-directions. To ensure proper functioning of the 3D-CMUT unit, the resonant frequencies of the three composed cells are set to be identical by adjusting the microstructural parameters appropriately. Moreover, the same sensitivity in the x, y, and z-directions is theoretically achieved by tuning the amplification parameters in the external circuit. We establish a transient analysis model of the 3D-CMUT using COMSOL finite element simulation software to confirm its ability to sense multimode ultrasonic guided waves, including A(0), S(0), and SH(0) modes. Additionally, we simulate the ball drop impact acoustic emission signal on a plate to demonstrate that the 3D-CMUT can not only utilize in-plane information for positioning but also out-of-plane information. The proposed 3D-CMUT holds significant potential for applications in the field of structural health monitoring (SHM). MDPI 2023-10-25 /pmc/articles/PMC10647637/ /pubmed/37960406 http://dx.doi.org/10.3390/s23218706 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Sai
Lu, Wei
Wang, Ailing
Hao, Guodong
Wang, Renxing
Yilmaz, Mehmet
Design and Finite Element Simulation of a Novel 3D-CMUT Device for Simultaneous Sensing of In-Plane and Out-of-Plane Displacements of Ultrasonic Guided Waves
title Design and Finite Element Simulation of a Novel 3D-CMUT Device for Simultaneous Sensing of In-Plane and Out-of-Plane Displacements of Ultrasonic Guided Waves
title_full Design and Finite Element Simulation of a Novel 3D-CMUT Device for Simultaneous Sensing of In-Plane and Out-of-Plane Displacements of Ultrasonic Guided Waves
title_fullStr Design and Finite Element Simulation of a Novel 3D-CMUT Device for Simultaneous Sensing of In-Plane and Out-of-Plane Displacements of Ultrasonic Guided Waves
title_full_unstemmed Design and Finite Element Simulation of a Novel 3D-CMUT Device for Simultaneous Sensing of In-Plane and Out-of-Plane Displacements of Ultrasonic Guided Waves
title_short Design and Finite Element Simulation of a Novel 3D-CMUT Device for Simultaneous Sensing of In-Plane and Out-of-Plane Displacements of Ultrasonic Guided Waves
title_sort design and finite element simulation of a novel 3d-cmut device for simultaneous sensing of in-plane and out-of-plane displacements of ultrasonic guided waves
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10647637/
https://www.ncbi.nlm.nih.gov/pubmed/37960406
http://dx.doi.org/10.3390/s23218706
work_keys_str_mv AT zhangsai designandfiniteelementsimulationofanovel3dcmutdeviceforsimultaneoussensingofinplaneandoutofplanedisplacementsofultrasonicguidedwaves
AT luwei designandfiniteelementsimulationofanovel3dcmutdeviceforsimultaneoussensingofinplaneandoutofplanedisplacementsofultrasonicguidedwaves
AT wangailing designandfiniteelementsimulationofanovel3dcmutdeviceforsimultaneoussensingofinplaneandoutofplanedisplacementsofultrasonicguidedwaves
AT haoguodong designandfiniteelementsimulationofanovel3dcmutdeviceforsimultaneoussensingofinplaneandoutofplanedisplacementsofultrasonicguidedwaves
AT wangrenxing designandfiniteelementsimulationofanovel3dcmutdeviceforsimultaneoussensingofinplaneandoutofplanedisplacementsofultrasonicguidedwaves
AT yilmazmehmet designandfiniteelementsimulationofanovel3dcmutdeviceforsimultaneoussensingofinplaneandoutofplanedisplacementsofultrasonicguidedwaves