Cargando…

Computed Tomography-Based Coronary Artery Calcium Score Calculation at a Reduced Tube Voltage Utilizing Iterative Reconstruction and Threshold Modification Techniques: A Feasibility Study

Background: The coronary artery calcium score (CACS) indicates cardiovascular health. A concern in this regard is the ionizing radiation from computed tomography (CT). Recent studies have tried to introduce low-dose CT techniques to assess CACS. We aimed to investigate the accuracy of iterative reco...

Descripción completa

Detalles Bibliográficos
Autores principales: Habibi, Shirin, Akbarnejad, Mohammad, Rezaeian, Nahid, Salmanipour, Alireza, Mohammadzadeh, Ali, Rezaei-Kalantari, Kiara, Chalian, Hamid, Asadian, Sanaz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10648177/
https://www.ncbi.nlm.nih.gov/pubmed/37958211
http://dx.doi.org/10.3390/diagnostics13213315
_version_ 1785135279038791680
author Habibi, Shirin
Akbarnejad, Mohammad
Rezaeian, Nahid
Salmanipour, Alireza
Mohammadzadeh, Ali
Rezaei-Kalantari, Kiara
Chalian, Hamid
Asadian, Sanaz
author_facet Habibi, Shirin
Akbarnejad, Mohammad
Rezaeian, Nahid
Salmanipour, Alireza
Mohammadzadeh, Ali
Rezaei-Kalantari, Kiara
Chalian, Hamid
Asadian, Sanaz
author_sort Habibi, Shirin
collection PubMed
description Background: The coronary artery calcium score (CACS) indicates cardiovascular health. A concern in this regard is the ionizing radiation from computed tomography (CT). Recent studies have tried to introduce low-dose CT techniques to assess CACS. We aimed to investigate the accuracy of iterative reconstruction (IR) and threshold modification while applying low tube voltage in coronary artery calcium imaging. Methods: The study population consisted of 107 patients. Each subject underwent an electrocardiogram-gated CT twice, once with a standard voltage of 120 kVp and then a reduced voltage of 80 kVp. The standard filtered back projection (FBP) reconstruction was applied in both voltages. Considering Hounsfield unit (HU) thresholds other than 130 (150, 170, and 190), CACS was calculated using the FBP-reconstructed 80 kVp images. Moreover, the 80 kVp images were reconstructed utilizing IR at different strength levels. CACS was measured in each set of images. The intraclass correlation coefficient (ICC) was used to compare the CACSs. Results: A 64% reduction in the effective dose was observed in the 80 kVp protocol compared to the 120 kVp protocol. Excellent agreement existed between CACS at high-level (strength level = 5) IR in low-kVp images and the standard CACS protocol in scores ≥ 11 (ICC > 0.9 and p < 0.05). Increasing the threshold density to 190 HU in FBP-reconstructed low-kVp images yielded excellent agreement with the standard protocol in scores ≥ 11 (ICC > 0.9 and p < 0.05) and good agreement in score zero (ICC = 0.84 and p = 0.02). Conclusions: The modification of the density threshold and IR provides an accurate calculation of CACS in low-voltage CT with the potential to decrease patient radiation exposure.
format Online
Article
Text
id pubmed-10648177
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106481772023-10-26 Computed Tomography-Based Coronary Artery Calcium Score Calculation at a Reduced Tube Voltage Utilizing Iterative Reconstruction and Threshold Modification Techniques: A Feasibility Study Habibi, Shirin Akbarnejad, Mohammad Rezaeian, Nahid Salmanipour, Alireza Mohammadzadeh, Ali Rezaei-Kalantari, Kiara Chalian, Hamid Asadian, Sanaz Diagnostics (Basel) Article Background: The coronary artery calcium score (CACS) indicates cardiovascular health. A concern in this regard is the ionizing radiation from computed tomography (CT). Recent studies have tried to introduce low-dose CT techniques to assess CACS. We aimed to investigate the accuracy of iterative reconstruction (IR) and threshold modification while applying low tube voltage in coronary artery calcium imaging. Methods: The study population consisted of 107 patients. Each subject underwent an electrocardiogram-gated CT twice, once with a standard voltage of 120 kVp and then a reduced voltage of 80 kVp. The standard filtered back projection (FBP) reconstruction was applied in both voltages. Considering Hounsfield unit (HU) thresholds other than 130 (150, 170, and 190), CACS was calculated using the FBP-reconstructed 80 kVp images. Moreover, the 80 kVp images were reconstructed utilizing IR at different strength levels. CACS was measured in each set of images. The intraclass correlation coefficient (ICC) was used to compare the CACSs. Results: A 64% reduction in the effective dose was observed in the 80 kVp protocol compared to the 120 kVp protocol. Excellent agreement existed between CACS at high-level (strength level = 5) IR in low-kVp images and the standard CACS protocol in scores ≥ 11 (ICC > 0.9 and p < 0.05). Increasing the threshold density to 190 HU in FBP-reconstructed low-kVp images yielded excellent agreement with the standard protocol in scores ≥ 11 (ICC > 0.9 and p < 0.05) and good agreement in score zero (ICC = 0.84 and p = 0.02). Conclusions: The modification of the density threshold and IR provides an accurate calculation of CACS in low-voltage CT with the potential to decrease patient radiation exposure. MDPI 2023-10-26 /pmc/articles/PMC10648177/ /pubmed/37958211 http://dx.doi.org/10.3390/diagnostics13213315 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Habibi, Shirin
Akbarnejad, Mohammad
Rezaeian, Nahid
Salmanipour, Alireza
Mohammadzadeh, Ali
Rezaei-Kalantari, Kiara
Chalian, Hamid
Asadian, Sanaz
Computed Tomography-Based Coronary Artery Calcium Score Calculation at a Reduced Tube Voltage Utilizing Iterative Reconstruction and Threshold Modification Techniques: A Feasibility Study
title Computed Tomography-Based Coronary Artery Calcium Score Calculation at a Reduced Tube Voltage Utilizing Iterative Reconstruction and Threshold Modification Techniques: A Feasibility Study
title_full Computed Tomography-Based Coronary Artery Calcium Score Calculation at a Reduced Tube Voltage Utilizing Iterative Reconstruction and Threshold Modification Techniques: A Feasibility Study
title_fullStr Computed Tomography-Based Coronary Artery Calcium Score Calculation at a Reduced Tube Voltage Utilizing Iterative Reconstruction and Threshold Modification Techniques: A Feasibility Study
title_full_unstemmed Computed Tomography-Based Coronary Artery Calcium Score Calculation at a Reduced Tube Voltage Utilizing Iterative Reconstruction and Threshold Modification Techniques: A Feasibility Study
title_short Computed Tomography-Based Coronary Artery Calcium Score Calculation at a Reduced Tube Voltage Utilizing Iterative Reconstruction and Threshold Modification Techniques: A Feasibility Study
title_sort computed tomography-based coronary artery calcium score calculation at a reduced tube voltage utilizing iterative reconstruction and threshold modification techniques: a feasibility study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10648177/
https://www.ncbi.nlm.nih.gov/pubmed/37958211
http://dx.doi.org/10.3390/diagnostics13213315
work_keys_str_mv AT habibishirin computedtomographybasedcoronaryarterycalciumscorecalculationatareducedtubevoltageutilizingiterativereconstructionandthresholdmodificationtechniquesafeasibilitystudy
AT akbarnejadmohammad computedtomographybasedcoronaryarterycalciumscorecalculationatareducedtubevoltageutilizingiterativereconstructionandthresholdmodificationtechniquesafeasibilitystudy
AT rezaeiannahid computedtomographybasedcoronaryarterycalciumscorecalculationatareducedtubevoltageutilizingiterativereconstructionandthresholdmodificationtechniquesafeasibilitystudy
AT salmanipouralireza computedtomographybasedcoronaryarterycalciumscorecalculationatareducedtubevoltageutilizingiterativereconstructionandthresholdmodificationtechniquesafeasibilitystudy
AT mohammadzadehali computedtomographybasedcoronaryarterycalciumscorecalculationatareducedtubevoltageutilizingiterativereconstructionandthresholdmodificationtechniquesafeasibilitystudy
AT rezaeikalantarikiara computedtomographybasedcoronaryarterycalciumscorecalculationatareducedtubevoltageutilizingiterativereconstructionandthresholdmodificationtechniquesafeasibilitystudy
AT chalianhamid computedtomographybasedcoronaryarterycalciumscorecalculationatareducedtubevoltageutilizingiterativereconstructionandthresholdmodificationtechniquesafeasibilitystudy
AT asadiansanaz computedtomographybasedcoronaryarterycalciumscorecalculationatareducedtubevoltageutilizingiterativereconstructionandthresholdmodificationtechniquesafeasibilitystudy