Cargando…
Clinical Outcome of Carbon Fiber Reinforced Polyetheretherketone Plates in Patients with Proximal Humeral Fracture: One-Year Follow-Up
Background: Proximal humerus fractures are seen frequently, particularly in older patients. The development of new osteosynthesis materials is being driven by the high complication rates following surgical treatment of proximal humerus fractures. Plate osteosyntheses made of steel, titanium and, for...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10648264/ https://www.ncbi.nlm.nih.gov/pubmed/37959346 http://dx.doi.org/10.3390/jcm12216881 |
_version_ | 1785135299871899648 |
---|---|
author | Ziegler, Patrick Maier, Sven Stuby, Fabian Histing, Tina Ihle, Christoph Stöckle, Ulrich Gühring, Markus |
author_facet | Ziegler, Patrick Maier, Sven Stuby, Fabian Histing, Tina Ihle, Christoph Stöckle, Ulrich Gühring, Markus |
author_sort | Ziegler, Patrick |
collection | PubMed |
description | Background: Proximal humerus fractures are seen frequently, particularly in older patients. The development of new osteosynthesis materials is being driven by the high complication rates following surgical treatment of proximal humerus fractures. Plate osteosyntheses made of steel, titanium and, for several years now, carbon fiber-reinforced polyetheretherketone (CFR-PEEK) are used most frequently. Methods: A prospective, randomized study was conducted in order to evaluate whether there are differences in the functional postoperative outcome when comparing CFR-PEEK and titanium implants for surgical treatment of proximal humerus fractures. The primary outcome of shoulder functionality 1 year after surgery was measured with the DASH score, the Oxford Shoulder Score, and the Simple Shoulder Test. Results: Bony consolidation of the respective fracture was confirmed in all the patients included in the study within the scope of postoperative follow-up care. No significant differences in the DASH score, Oxford Shoulder Score, or Simple Shoulder Test were observed 1 year post-operatively when comparing the implant materials CFR-PEEK and titanium. Conclusions: There are no differences in terms of the functional outcome between CFR-PEEK plates and titanium implants 1 year after surgery. Studies on the long-term outcomes using CFR-PEEK plates in osteoporotic bone should be the subject of further research. |
format | Online Article Text |
id | pubmed-10648264 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106482642023-10-31 Clinical Outcome of Carbon Fiber Reinforced Polyetheretherketone Plates in Patients with Proximal Humeral Fracture: One-Year Follow-Up Ziegler, Patrick Maier, Sven Stuby, Fabian Histing, Tina Ihle, Christoph Stöckle, Ulrich Gühring, Markus J Clin Med Article Background: Proximal humerus fractures are seen frequently, particularly in older patients. The development of new osteosynthesis materials is being driven by the high complication rates following surgical treatment of proximal humerus fractures. Plate osteosyntheses made of steel, titanium and, for several years now, carbon fiber-reinforced polyetheretherketone (CFR-PEEK) are used most frequently. Methods: A prospective, randomized study was conducted in order to evaluate whether there are differences in the functional postoperative outcome when comparing CFR-PEEK and titanium implants for surgical treatment of proximal humerus fractures. The primary outcome of shoulder functionality 1 year after surgery was measured with the DASH score, the Oxford Shoulder Score, and the Simple Shoulder Test. Results: Bony consolidation of the respective fracture was confirmed in all the patients included in the study within the scope of postoperative follow-up care. No significant differences in the DASH score, Oxford Shoulder Score, or Simple Shoulder Test were observed 1 year post-operatively when comparing the implant materials CFR-PEEK and titanium. Conclusions: There are no differences in terms of the functional outcome between CFR-PEEK plates and titanium implants 1 year after surgery. Studies on the long-term outcomes using CFR-PEEK plates in osteoporotic bone should be the subject of further research. MDPI 2023-10-31 /pmc/articles/PMC10648264/ /pubmed/37959346 http://dx.doi.org/10.3390/jcm12216881 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ziegler, Patrick Maier, Sven Stuby, Fabian Histing, Tina Ihle, Christoph Stöckle, Ulrich Gühring, Markus Clinical Outcome of Carbon Fiber Reinforced Polyetheretherketone Plates in Patients with Proximal Humeral Fracture: One-Year Follow-Up |
title | Clinical Outcome of Carbon Fiber Reinforced Polyetheretherketone Plates in Patients with Proximal Humeral Fracture: One-Year Follow-Up |
title_full | Clinical Outcome of Carbon Fiber Reinforced Polyetheretherketone Plates in Patients with Proximal Humeral Fracture: One-Year Follow-Up |
title_fullStr | Clinical Outcome of Carbon Fiber Reinforced Polyetheretherketone Plates in Patients with Proximal Humeral Fracture: One-Year Follow-Up |
title_full_unstemmed | Clinical Outcome of Carbon Fiber Reinforced Polyetheretherketone Plates in Patients with Proximal Humeral Fracture: One-Year Follow-Up |
title_short | Clinical Outcome of Carbon Fiber Reinforced Polyetheretherketone Plates in Patients with Proximal Humeral Fracture: One-Year Follow-Up |
title_sort | clinical outcome of carbon fiber reinforced polyetheretherketone plates in patients with proximal humeral fracture: one-year follow-up |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10648264/ https://www.ncbi.nlm.nih.gov/pubmed/37959346 http://dx.doi.org/10.3390/jcm12216881 |
work_keys_str_mv | AT zieglerpatrick clinicaloutcomeofcarbonfiberreinforcedpolyetheretherketoneplatesinpatientswithproximalhumeralfractureoneyearfollowup AT maiersven clinicaloutcomeofcarbonfiberreinforcedpolyetheretherketoneplatesinpatientswithproximalhumeralfractureoneyearfollowup AT stubyfabian clinicaloutcomeofcarbonfiberreinforcedpolyetheretherketoneplatesinpatientswithproximalhumeralfractureoneyearfollowup AT histingtina clinicaloutcomeofcarbonfiberreinforcedpolyetheretherketoneplatesinpatientswithproximalhumeralfractureoneyearfollowup AT ihlechristoph clinicaloutcomeofcarbonfiberreinforcedpolyetheretherketoneplatesinpatientswithproximalhumeralfractureoneyearfollowup AT stockleulrich clinicaloutcomeofcarbonfiberreinforcedpolyetheretherketoneplatesinpatientswithproximalhumeralfractureoneyearfollowup AT guhringmarkus clinicaloutcomeofcarbonfiberreinforcedpolyetheretherketoneplatesinpatientswithproximalhumeralfractureoneyearfollowup |