Cargando…

Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique

Wearable 2.0 research has been conducted on the manufacture of smart fitness wear that collects bio-signals through the wearing of a textile-based electrode. Among them, the electromyography (EMG) suit measures the electrical signals generated by the muscles to check their activity, such as contract...

Descripción completa

Detalles Bibliográficos
Autores principales: Rho, Soohyeon, Kim, Hyelim, Lim, Daeyoung, Jeong, Wonyoung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10648407/
https://www.ncbi.nlm.nih.gov/pubmed/37960710
http://dx.doi.org/10.3390/s23219012
_version_ 1785135332979638272
author Rho, Soohyeon
Kim, Hyelim
Lim, Daeyoung
Jeong, Wonyoung
author_facet Rho, Soohyeon
Kim, Hyelim
Lim, Daeyoung
Jeong, Wonyoung
author_sort Rho, Soohyeon
collection PubMed
description Wearable 2.0 research has been conducted on the manufacture of smart fitness wear that collects bio-signals through the wearing of a textile-based electrode. Among them, the electromyography (EMG) suit measures the electrical signals generated by the muscles to check their activity, such as contraction and relaxation. General gel-type electrodes have been reported to cause skin diseases due to an uncomfortable feel and skin irritation when attached to the skin for a long time. Dry electrodes of various materials are being developed to solve this problem. Previous research has reported EMG detectio performance and conducted economic comparisons according to the size and shape of the embroidery electrode. On the other hand, these embroidery electrodes still have foreign body sensations. In this study, a moss sEMG electrode was produced with various shapes (W3 and WF) and loop lengths (1–5 mm). The optimized conditions of the embroidery-based electrodes were derived and analyzed with the tactile comfort factors and sensing performances. As the loop length of the electrode increased, MIU and Qmax increased, but the SMD decreased due to the free movement of the threads constituting the loop. Impedance and sEMG detection performance showed different trends depending on the electrode type.
format Online
Article
Text
id pubmed-10648407
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106484072023-11-06 Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique Rho, Soohyeon Kim, Hyelim Lim, Daeyoung Jeong, Wonyoung Sensors (Basel) Article Wearable 2.0 research has been conducted on the manufacture of smart fitness wear that collects bio-signals through the wearing of a textile-based electrode. Among them, the electromyography (EMG) suit measures the electrical signals generated by the muscles to check their activity, such as contraction and relaxation. General gel-type electrodes have been reported to cause skin diseases due to an uncomfortable feel and skin irritation when attached to the skin for a long time. Dry electrodes of various materials are being developed to solve this problem. Previous research has reported EMG detectio performance and conducted economic comparisons according to the size and shape of the embroidery electrode. On the other hand, these embroidery electrodes still have foreign body sensations. In this study, a moss sEMG electrode was produced with various shapes (W3 and WF) and loop lengths (1–5 mm). The optimized conditions of the embroidery-based electrodes were derived and analyzed with the tactile comfort factors and sensing performances. As the loop length of the electrode increased, MIU and Qmax increased, but the SMD decreased due to the free movement of the threads constituting the loop. Impedance and sEMG detection performance showed different trends depending on the electrode type. MDPI 2023-11-06 /pmc/articles/PMC10648407/ /pubmed/37960710 http://dx.doi.org/10.3390/s23219012 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rho, Soohyeon
Kim, Hyelim
Lim, Daeyoung
Jeong, Wonyoung
Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique
title Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique
title_full Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique
title_fullStr Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique
title_full_unstemmed Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique
title_short Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique
title_sort fabrication and evaluation of embroidery-based electrode for emg smart wear using moss stitch technique
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10648407/
https://www.ncbi.nlm.nih.gov/pubmed/37960710
http://dx.doi.org/10.3390/s23219012
work_keys_str_mv AT rhosoohyeon fabricationandevaluationofembroiderybasedelectrodeforemgsmartwearusingmossstitchtechnique
AT kimhyelim fabricationandevaluationofembroiderybasedelectrodeforemgsmartwearusingmossstitchtechnique
AT limdaeyoung fabricationandevaluationofembroiderybasedelectrodeforemgsmartwearusingmossstitchtechnique
AT jeongwonyoung fabricationandevaluationofembroiderybasedelectrodeforemgsmartwearusingmossstitchtechnique