Cargando…

Analysis of the Impact of Electrochemical Properties of Copper-Doped Electrode Membranes on the Output Force of Biomimetic Artificial Muscles

In this study, a biomimetic artificial muscle electroactive actuator was fabricated using environmentally friendly sodium alginate extract. Ultrasonic agitation was employed to embed ultrafine copper powder within a mesh-like structure formed by multi-walled carbon nanotubes (MWCNTs), aimed at reduc...

Descripción completa

Detalles Bibliográficos
Autores principales: Ji, Yingxin, Wang, Keyi, Zhao, Gang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10648887/
https://www.ncbi.nlm.nih.gov/pubmed/37959894
http://dx.doi.org/10.3390/polym15214214
_version_ 1785135443528908800
author Ji, Yingxin
Wang, Keyi
Zhao, Gang
author_facet Ji, Yingxin
Wang, Keyi
Zhao, Gang
author_sort Ji, Yingxin
collection PubMed
description In this study, a biomimetic artificial muscle electroactive actuator was fabricated using environmentally friendly sodium alginate extract. Ultrasonic agitation was employed to embed ultrafine copper powder within a mesh-like structure formed by multi-walled carbon nanotubes (MWCNTs), aimed at reducing the internal resistance of the composite electrode membrane and enhancing its output force performance. Focused gallium ion beam-scanning electron microscopy observations, energy-dispersive X-ray spectroscopy (EDS) analysis, and surface morphology imaging confirmed the successful incorporation of the ultrafine copper powder into the MWCNT network. Additionally, we designed and constructed an output force measurement apparatus to assess the output performance of biomimetic artificial muscles (BMAMs) doped with varying quantities of ultrafine copper powder. Electrochemical testing results demonstrated that the artificial muscles exhibited optimal performance when doped with a mass of 1.5 g, yielding a maximum output force of 6.96 mN, an output force density of 30.64 mN/g, and a peak average rate of 0.059 mN/s. These values represented improvements of 224%, 189%, and 222% compared to the electrode membrane without the addition of ultrafine copper powder, respectively.
format Online
Article
Text
id pubmed-10648887
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106488872023-10-25 Analysis of the Impact of Electrochemical Properties of Copper-Doped Electrode Membranes on the Output Force of Biomimetic Artificial Muscles Ji, Yingxin Wang, Keyi Zhao, Gang Polymers (Basel) Article In this study, a biomimetic artificial muscle electroactive actuator was fabricated using environmentally friendly sodium alginate extract. Ultrasonic agitation was employed to embed ultrafine copper powder within a mesh-like structure formed by multi-walled carbon nanotubes (MWCNTs), aimed at reducing the internal resistance of the composite electrode membrane and enhancing its output force performance. Focused gallium ion beam-scanning electron microscopy observations, energy-dispersive X-ray spectroscopy (EDS) analysis, and surface morphology imaging confirmed the successful incorporation of the ultrafine copper powder into the MWCNT network. Additionally, we designed and constructed an output force measurement apparatus to assess the output performance of biomimetic artificial muscles (BMAMs) doped with varying quantities of ultrafine copper powder. Electrochemical testing results demonstrated that the artificial muscles exhibited optimal performance when doped with a mass of 1.5 g, yielding a maximum output force of 6.96 mN, an output force density of 30.64 mN/g, and a peak average rate of 0.059 mN/s. These values represented improvements of 224%, 189%, and 222% compared to the electrode membrane without the addition of ultrafine copper powder, respectively. MDPI 2023-10-25 /pmc/articles/PMC10648887/ /pubmed/37959894 http://dx.doi.org/10.3390/polym15214214 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ji, Yingxin
Wang, Keyi
Zhao, Gang
Analysis of the Impact of Electrochemical Properties of Copper-Doped Electrode Membranes on the Output Force of Biomimetic Artificial Muscles
title Analysis of the Impact of Electrochemical Properties of Copper-Doped Electrode Membranes on the Output Force of Biomimetic Artificial Muscles
title_full Analysis of the Impact of Electrochemical Properties of Copper-Doped Electrode Membranes on the Output Force of Biomimetic Artificial Muscles
title_fullStr Analysis of the Impact of Electrochemical Properties of Copper-Doped Electrode Membranes on the Output Force of Biomimetic Artificial Muscles
title_full_unstemmed Analysis of the Impact of Electrochemical Properties of Copper-Doped Electrode Membranes on the Output Force of Biomimetic Artificial Muscles
title_short Analysis of the Impact of Electrochemical Properties of Copper-Doped Electrode Membranes on the Output Force of Biomimetic Artificial Muscles
title_sort analysis of the impact of electrochemical properties of copper-doped electrode membranes on the output force of biomimetic artificial muscles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10648887/
https://www.ncbi.nlm.nih.gov/pubmed/37959894
http://dx.doi.org/10.3390/polym15214214
work_keys_str_mv AT jiyingxin analysisoftheimpactofelectrochemicalpropertiesofcopperdopedelectrodemembranesontheoutputforceofbiomimeticartificialmuscles
AT wangkeyi analysisoftheimpactofelectrochemicalpropertiesofcopperdopedelectrodemembranesontheoutputforceofbiomimeticartificialmuscles
AT zhaogang analysisoftheimpactofelectrochemicalpropertiesofcopperdopedelectrodemembranesontheoutputforceofbiomimeticartificialmuscles