Cargando…
Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine
In this study, TpDMB-COPs, a specific class of covalent organic polymers (COPs), was synthesized using Schiff-base chemistry and incorporated into a polyvinylidene fluoride (PVDF) polymer for the first time to prepare COPs mixed matrix membranes (TpDMB-COPs-MMM). A membrane solid-phase extraction (M...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649119/ https://www.ncbi.nlm.nih.gov/pubmed/37959757 http://dx.doi.org/10.3390/molecules28217336 |
_version_ | 1785135493196808192 |
---|---|
author | Liu, Ying Zhang, Yong Wang, Jing Wang, Kexin Gao, Shuming Cui, Ruiqi Liu, Fubin Gao, Guihua |
author_facet | Liu, Ying Zhang, Yong Wang, Jing Wang, Kexin Gao, Shuming Cui, Ruiqi Liu, Fubin Gao, Guihua |
author_sort | Liu, Ying |
collection | PubMed |
description | In this study, TpDMB-COPs, a specific class of covalent organic polymers (COPs), was synthesized using Schiff-base chemistry and incorporated into a polyvinylidene fluoride (PVDF) polymer for the first time to prepare COPs mixed matrix membranes (TpDMB-COPs-MMM). A membrane solid-phase extraction (ME) method based on the TpDMB-COPs-MMM was developed to extract trace levels of six sulfonamides from human urine identified by high-performance liquid chromatography (HPLC). The key factors affecting the extraction efficiency were investigated. Under the optimum conditions, the proposed method demonstrated an excellent linear relationship in the range of 3.5–25 ng/mL (r(2) ≥ 0.9991), with the low limits of detection (LOD) between 1.25 ng/mL and 2.50 ng/mL and the limit of quantification (LOQ) between 3.50 ng/mL and 7.00 ng/mL. Intra-day and inter-day accuracies were below 5.0%. The method’s accuracy was assessed by recovery experiments using human urine spiked at three levels (7–14 ng/mL, 10–15 ng/mL, and 16–20 ng/mL). The recoveries ranged from 87.4 to 112.2% with relative standard deviations (RSD) ≤ 8.7%, confirming the applicability of the proposed method. The developed ME method based on TpDMB-COPs-MMM offered advantages, including simple operation, superior extraction affinity, excellent recycling performance, and easy removal and separation from the solution. The prepared TpDMB-COPs-MMM was demonstrated to be a promising adsorbent for ME in the pre-concentration of trace organic compounds from complex matrices, expanding the application of COPs and providing references for other porous materials in sample pre-treatment. |
format | Online Article Text |
id | pubmed-10649119 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106491192023-10-30 Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine Liu, Ying Zhang, Yong Wang, Jing Wang, Kexin Gao, Shuming Cui, Ruiqi Liu, Fubin Gao, Guihua Molecules Article In this study, TpDMB-COPs, a specific class of covalent organic polymers (COPs), was synthesized using Schiff-base chemistry and incorporated into a polyvinylidene fluoride (PVDF) polymer for the first time to prepare COPs mixed matrix membranes (TpDMB-COPs-MMM). A membrane solid-phase extraction (ME) method based on the TpDMB-COPs-MMM was developed to extract trace levels of six sulfonamides from human urine identified by high-performance liquid chromatography (HPLC). The key factors affecting the extraction efficiency were investigated. Under the optimum conditions, the proposed method demonstrated an excellent linear relationship in the range of 3.5–25 ng/mL (r(2) ≥ 0.9991), with the low limits of detection (LOD) between 1.25 ng/mL and 2.50 ng/mL and the limit of quantification (LOQ) between 3.50 ng/mL and 7.00 ng/mL. Intra-day and inter-day accuracies were below 5.0%. The method’s accuracy was assessed by recovery experiments using human urine spiked at three levels (7–14 ng/mL, 10–15 ng/mL, and 16–20 ng/mL). The recoveries ranged from 87.4 to 112.2% with relative standard deviations (RSD) ≤ 8.7%, confirming the applicability of the proposed method. The developed ME method based on TpDMB-COPs-MMM offered advantages, including simple operation, superior extraction affinity, excellent recycling performance, and easy removal and separation from the solution. The prepared TpDMB-COPs-MMM was demonstrated to be a promising adsorbent for ME in the pre-concentration of trace organic compounds from complex matrices, expanding the application of COPs and providing references for other porous materials in sample pre-treatment. MDPI 2023-10-30 /pmc/articles/PMC10649119/ /pubmed/37959757 http://dx.doi.org/10.3390/molecules28217336 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Liu, Ying Zhang, Yong Wang, Jing Wang, Kexin Gao, Shuming Cui, Ruiqi Liu, Fubin Gao, Guihua Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine |
title | Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine |
title_full | Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine |
title_fullStr | Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine |
title_full_unstemmed | Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine |
title_short | Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine |
title_sort | preparation of cops mixed matrix membrane for sensitive determination of six sulfonamides in human urine |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649119/ https://www.ncbi.nlm.nih.gov/pubmed/37959757 http://dx.doi.org/10.3390/molecules28217336 |
work_keys_str_mv | AT liuying preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine AT zhangyong preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine AT wangjing preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine AT wangkexin preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine AT gaoshuming preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine AT cuiruiqi preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine AT liufubin preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine AT gaoguihua preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine |