Cargando…

Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine

In this study, TpDMB-COPs, a specific class of covalent organic polymers (COPs), was synthesized using Schiff-base chemistry and incorporated into a polyvinylidene fluoride (PVDF) polymer for the first time to prepare COPs mixed matrix membranes (TpDMB-COPs-MMM). A membrane solid-phase extraction (M...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Ying, Zhang, Yong, Wang, Jing, Wang, Kexin, Gao, Shuming, Cui, Ruiqi, Liu, Fubin, Gao, Guihua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649119/
https://www.ncbi.nlm.nih.gov/pubmed/37959757
http://dx.doi.org/10.3390/molecules28217336
_version_ 1785135493196808192
author Liu, Ying
Zhang, Yong
Wang, Jing
Wang, Kexin
Gao, Shuming
Cui, Ruiqi
Liu, Fubin
Gao, Guihua
author_facet Liu, Ying
Zhang, Yong
Wang, Jing
Wang, Kexin
Gao, Shuming
Cui, Ruiqi
Liu, Fubin
Gao, Guihua
author_sort Liu, Ying
collection PubMed
description In this study, TpDMB-COPs, a specific class of covalent organic polymers (COPs), was synthesized using Schiff-base chemistry and incorporated into a polyvinylidene fluoride (PVDF) polymer for the first time to prepare COPs mixed matrix membranes (TpDMB-COPs-MMM). A membrane solid-phase extraction (ME) method based on the TpDMB-COPs-MMM was developed to extract trace levels of six sulfonamides from human urine identified by high-performance liquid chromatography (HPLC). The key factors affecting the extraction efficiency were investigated. Under the optimum conditions, the proposed method demonstrated an excellent linear relationship in the range of 3.5–25 ng/mL (r(2) ≥ 0.9991), with the low limits of detection (LOD) between 1.25 ng/mL and 2.50 ng/mL and the limit of quantification (LOQ) between 3.50 ng/mL and 7.00 ng/mL. Intra-day and inter-day accuracies were below 5.0%. The method’s accuracy was assessed by recovery experiments using human urine spiked at three levels (7–14 ng/mL, 10–15 ng/mL, and 16–20 ng/mL). The recoveries ranged from 87.4 to 112.2% with relative standard deviations (RSD) ≤ 8.7%, confirming the applicability of the proposed method. The developed ME method based on TpDMB-COPs-MMM offered advantages, including simple operation, superior extraction affinity, excellent recycling performance, and easy removal and separation from the solution. The prepared TpDMB-COPs-MMM was demonstrated to be a promising adsorbent for ME in the pre-concentration of trace organic compounds from complex matrices, expanding the application of COPs and providing references for other porous materials in sample pre-treatment.
format Online
Article
Text
id pubmed-10649119
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106491192023-10-30 Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine Liu, Ying Zhang, Yong Wang, Jing Wang, Kexin Gao, Shuming Cui, Ruiqi Liu, Fubin Gao, Guihua Molecules Article In this study, TpDMB-COPs, a specific class of covalent organic polymers (COPs), was synthesized using Schiff-base chemistry and incorporated into a polyvinylidene fluoride (PVDF) polymer for the first time to prepare COPs mixed matrix membranes (TpDMB-COPs-MMM). A membrane solid-phase extraction (ME) method based on the TpDMB-COPs-MMM was developed to extract trace levels of six sulfonamides from human urine identified by high-performance liquid chromatography (HPLC). The key factors affecting the extraction efficiency were investigated. Under the optimum conditions, the proposed method demonstrated an excellent linear relationship in the range of 3.5–25 ng/mL (r(2) ≥ 0.9991), with the low limits of detection (LOD) between 1.25 ng/mL and 2.50 ng/mL and the limit of quantification (LOQ) between 3.50 ng/mL and 7.00 ng/mL. Intra-day and inter-day accuracies were below 5.0%. The method’s accuracy was assessed by recovery experiments using human urine spiked at three levels (7–14 ng/mL, 10–15 ng/mL, and 16–20 ng/mL). The recoveries ranged from 87.4 to 112.2% with relative standard deviations (RSD) ≤ 8.7%, confirming the applicability of the proposed method. The developed ME method based on TpDMB-COPs-MMM offered advantages, including simple operation, superior extraction affinity, excellent recycling performance, and easy removal and separation from the solution. The prepared TpDMB-COPs-MMM was demonstrated to be a promising adsorbent for ME in the pre-concentration of trace organic compounds from complex matrices, expanding the application of COPs and providing references for other porous materials in sample pre-treatment. MDPI 2023-10-30 /pmc/articles/PMC10649119/ /pubmed/37959757 http://dx.doi.org/10.3390/molecules28217336 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Ying
Zhang, Yong
Wang, Jing
Wang, Kexin
Gao, Shuming
Cui, Ruiqi
Liu, Fubin
Gao, Guihua
Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine
title Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine
title_full Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine
title_fullStr Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine
title_full_unstemmed Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine
title_short Preparation of COPs Mixed Matrix Membrane for Sensitive Determination of Six Sulfonamides in Human Urine
title_sort preparation of cops mixed matrix membrane for sensitive determination of six sulfonamides in human urine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649119/
https://www.ncbi.nlm.nih.gov/pubmed/37959757
http://dx.doi.org/10.3390/molecules28217336
work_keys_str_mv AT liuying preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine
AT zhangyong preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine
AT wangjing preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine
AT wangkexin preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine
AT gaoshuming preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine
AT cuiruiqi preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine
AT liufubin preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine
AT gaoguihua preparationofcopsmixedmatrixmembraneforsensitivedeterminationofsixsulfonamidesinhumanurine