Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers

Polymeric materials show great promise for use in a variety of dental applications. Manufacturers generally provide flexural strength information based on standardized (ISO and ASTM) specimen dimensions and loading conditions. It is not clear, however, if flexural strength data are predictive of the...

Descripción completa

Detalles Bibliográficos
Autor principal: Alghazzawi, Tariq F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649243/
https://www.ncbi.nlm.nih.gov/pubmed/37959992
http://dx.doi.org/10.3390/polym15214312
_version_ 1785135521604829184
author Alghazzawi, Tariq F.
author_facet Alghazzawi, Tariq F.
author_sort Alghazzawi, Tariq F.
collection PubMed
description Polymeric materials show great promise for use in a variety of dental applications. Manufacturers generally provide flexural strength information based on standardized (ISO and ASTM) specimen dimensions and loading conditions. It is not clear, however, if flexural strength data are predictive of the clinical performance of dental crowns. The objectives of this study were, therefore, to determine whether flexural strengths, as measured via three-point bending (3PB), would be predictive of failure loads assessed via crunch-the-crown (CTC) tests. Three brands of polymers (Trilor, Juvora, and Pekkton) were fabricated into rectangular bars and fully contoured crowns (10 specimens of each polymer brand, 30 specimens of each shape). Differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), and burn off tests were used to characterize/confirm the materials. Bars were tested blindly in 3PB to determine flexural strength, and crowns were CTC-tested to determine failure load after luting to resin abutments. The statistical significance of the test results was evaluated via one-way ANOVA (α = 0.05) and Pearson’s correlation coefficient, while regression analysis was used to test for a correlation between 3PB and CTC results. The fracture mechanisms and failure surface characteristics were characterized using scanning electron microscopy (SEM). There were significant differences (p < 0.05) in the mean crown failure loads (Trilor (7033 N) > Juvora (5217 N) > Pekkton (3023 N)) and mean flexural strengths of the bars (Trilor (468 MPa) > Juvora (197 MPa) = Pekkton (192 MPa)). The mode of crown fracture was different between the materials and included deformation (Juvora), ductile-to-brittle fracture (Pekkton), and a combination of cracks and deformation (Trilor). Flexural strengths did not correlate with the corresponding crown failure loads for any of the materials tested. These results suggest that dental practitioners should not rely on the flexural strengths reported from three-point bending tests, as advertised by the manufacturer, to predict the performance of polymeric crowns.
format Online
Article
Text
id pubmed-10649243
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106492432023-11-03 Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers Alghazzawi, Tariq F. Polymers (Basel) Article Polymeric materials show great promise for use in a variety of dental applications. Manufacturers generally provide flexural strength information based on standardized (ISO and ASTM) specimen dimensions and loading conditions. It is not clear, however, if flexural strength data are predictive of the clinical performance of dental crowns. The objectives of this study were, therefore, to determine whether flexural strengths, as measured via three-point bending (3PB), would be predictive of failure loads assessed via crunch-the-crown (CTC) tests. Three brands of polymers (Trilor, Juvora, and Pekkton) were fabricated into rectangular bars and fully contoured crowns (10 specimens of each polymer brand, 30 specimens of each shape). Differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), and burn off tests were used to characterize/confirm the materials. Bars were tested blindly in 3PB to determine flexural strength, and crowns were CTC-tested to determine failure load after luting to resin abutments. The statistical significance of the test results was evaluated via one-way ANOVA (α = 0.05) and Pearson’s correlation coefficient, while regression analysis was used to test for a correlation between 3PB and CTC results. The fracture mechanisms and failure surface characteristics were characterized using scanning electron microscopy (SEM). There were significant differences (p < 0.05) in the mean crown failure loads (Trilor (7033 N) > Juvora (5217 N) > Pekkton (3023 N)) and mean flexural strengths of the bars (Trilor (468 MPa) > Juvora (197 MPa) = Pekkton (192 MPa)). The mode of crown fracture was different between the materials and included deformation (Juvora), ductile-to-brittle fracture (Pekkton), and a combination of cracks and deformation (Trilor). Flexural strengths did not correlate with the corresponding crown failure loads for any of the materials tested. These results suggest that dental practitioners should not rely on the flexural strengths reported from three-point bending tests, as advertised by the manufacturer, to predict the performance of polymeric crowns. MDPI 2023-11-03 /pmc/articles/PMC10649243/ /pubmed/37959992 http://dx.doi.org/10.3390/polym15214312 Text en © 2023 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Alghazzawi, Tariq F.
Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers
title Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers
title_full Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers
title_fullStr Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers
title_full_unstemmed Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers
title_short Relation of Crown Failure Load to Flexural Strength for Three Contemporary Dental Polymers
title_sort relation of crown failure load to flexural strength for three contemporary dental polymers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649243/
https://www.ncbi.nlm.nih.gov/pubmed/37959992
http://dx.doi.org/10.3390/polym15214312
work_keys_str_mv AT alghazzawitariqf relationofcrownfailureloadtoflexuralstrengthforthreecontemporarydentalpolymers