Cargando…
Calibration of Yld2000-2D Anisotropy Yield Criterion with Traditional Testing and Inverse Identification Strategies
In order to improve predictive capabilities of numerical simulations, Yld2000-2D yield criterion is used to model the plastic anisotropic behaviors of AA5086 sheets. The parameters of Yld2000-2D yield criterion are identified based on the traditional testing strategy and the inverse identification s...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649632/ https://www.ncbi.nlm.nih.gov/pubmed/37959501 http://dx.doi.org/10.3390/ma16216904 |
_version_ | 1785135596613664768 |
---|---|
author | Chen, Jiaqi Wang, Zhihao Chu, Xingrong Yue, Zhenming Zhao, Chao Zhou, Yiqi |
author_facet | Chen, Jiaqi Wang, Zhihao Chu, Xingrong Yue, Zhenming Zhao, Chao Zhou, Yiqi |
author_sort | Chen, Jiaqi |
collection | PubMed |
description | In order to improve predictive capabilities of numerical simulations, Yld2000-2D yield criterion is used to model the plastic anisotropic behaviors of AA5086 sheets. The parameters of Yld2000-2D yield criterion are identified based on the traditional testing strategy and the inverse identification strategy, respectively. The traditional testing strategy considers uniaxial and equi-biaxial tensile tests. The inverse identification strategy relies on the finite element model update (FEMU) method that couples with a biaxial tensile test using a dedicated cruciform specimen or the Pottier bulging test. The identified parameters are preliminarily evaluated by comparing predicted and experimental yield stresses, r-values, and yield loci. Then, the deep drawing test and simulations are performed. The identified parameter sets of Yld2000-2D yield criterion are further evaluated in terms of practical forming by comparing the predicted earing profile height with the experimental results. The results show that the inverse identification strategy can be an effective alternative to identify the parameters of Yld2000-2D yield criterion, and a well-designed heterogeneous test could lead to a better identification result. |
format | Online Article Text |
id | pubmed-10649632 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106496322023-10-27 Calibration of Yld2000-2D Anisotropy Yield Criterion with Traditional Testing and Inverse Identification Strategies Chen, Jiaqi Wang, Zhihao Chu, Xingrong Yue, Zhenming Zhao, Chao Zhou, Yiqi Materials (Basel) Article In order to improve predictive capabilities of numerical simulations, Yld2000-2D yield criterion is used to model the plastic anisotropic behaviors of AA5086 sheets. The parameters of Yld2000-2D yield criterion are identified based on the traditional testing strategy and the inverse identification strategy, respectively. The traditional testing strategy considers uniaxial and equi-biaxial tensile tests. The inverse identification strategy relies on the finite element model update (FEMU) method that couples with a biaxial tensile test using a dedicated cruciform specimen or the Pottier bulging test. The identified parameters are preliminarily evaluated by comparing predicted and experimental yield stresses, r-values, and yield loci. Then, the deep drawing test and simulations are performed. The identified parameter sets of Yld2000-2D yield criterion are further evaluated in terms of practical forming by comparing the predicted earing profile height with the experimental results. The results show that the inverse identification strategy can be an effective alternative to identify the parameters of Yld2000-2D yield criterion, and a well-designed heterogeneous test could lead to a better identification result. MDPI 2023-10-27 /pmc/articles/PMC10649632/ /pubmed/37959501 http://dx.doi.org/10.3390/ma16216904 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chen, Jiaqi Wang, Zhihao Chu, Xingrong Yue, Zhenming Zhao, Chao Zhou, Yiqi Calibration of Yld2000-2D Anisotropy Yield Criterion with Traditional Testing and Inverse Identification Strategies |
title | Calibration of Yld2000-2D Anisotropy Yield Criterion with Traditional Testing and Inverse Identification Strategies |
title_full | Calibration of Yld2000-2D Anisotropy Yield Criterion with Traditional Testing and Inverse Identification Strategies |
title_fullStr | Calibration of Yld2000-2D Anisotropy Yield Criterion with Traditional Testing and Inverse Identification Strategies |
title_full_unstemmed | Calibration of Yld2000-2D Anisotropy Yield Criterion with Traditional Testing and Inverse Identification Strategies |
title_short | Calibration of Yld2000-2D Anisotropy Yield Criterion with Traditional Testing and Inverse Identification Strategies |
title_sort | calibration of yld2000-2d anisotropy yield criterion with traditional testing and inverse identification strategies |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649632/ https://www.ncbi.nlm.nih.gov/pubmed/37959501 http://dx.doi.org/10.3390/ma16216904 |
work_keys_str_mv | AT chenjiaqi calibrationofyld20002danisotropyyieldcriterionwithtraditionaltestingandinverseidentificationstrategies AT wangzhihao calibrationofyld20002danisotropyyieldcriterionwithtraditionaltestingandinverseidentificationstrategies AT chuxingrong calibrationofyld20002danisotropyyieldcriterionwithtraditionaltestingandinverseidentificationstrategies AT yuezhenming calibrationofyld20002danisotropyyieldcriterionwithtraditionaltestingandinverseidentificationstrategies AT zhaochao calibrationofyld20002danisotropyyieldcriterionwithtraditionaltestingandinverseidentificationstrategies AT zhouyiqi calibrationofyld20002danisotropyyieldcriterionwithtraditionaltestingandinverseidentificationstrategies |