An Integrated Approach for Real-Time Monitoring of Knee Dynamics with IMUs and Multichannel EMG

Measuring human joint dynamics is crucial for understanding how our bodies move and function, providing valuable insights into biomechanics and motor control. Cerebral palsy (CP) is a neurological disorder affecting motor control and posture, leading to diverse gait abnormalities, including altered...

Descripción completa

Detalles Bibliográficos
Autores principales: Malesevic, Nebojsa, Svensson, Ingrid, Hägglund, Gunnar, Antfolk, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649777/
https://www.ncbi.nlm.nih.gov/pubmed/37960654
http://dx.doi.org/10.3390/s23218955
_version_ 1785135629447725056
author Malesevic, Nebojsa
Svensson, Ingrid
Hägglund, Gunnar
Antfolk, Christian
author_facet Malesevic, Nebojsa
Svensson, Ingrid
Hägglund, Gunnar
Antfolk, Christian
author_sort Malesevic, Nebojsa
collection PubMed
description Measuring human joint dynamics is crucial for understanding how our bodies move and function, providing valuable insights into biomechanics and motor control. Cerebral palsy (CP) is a neurological disorder affecting motor control and posture, leading to diverse gait abnormalities, including altered knee angles. The accurate measurement and analysis of knee angles in individuals with CP are crucial for understanding their gait patterns, assessing treatment outcomes, and guiding interventions. This paper presents a novel multimodal approach that combines inertial measurement unit (IMU) sensors and electromyography (EMG) to measure knee angles in individuals with CP during gait and other daily activities. We discuss the performance of this integrated approach, highlighting the accuracy of IMU sensors in capturing knee joint movements when compared with an optical motion-tracking system and the complementary insights offered by EMG in assessing muscle activation patterns. Moreover, we delve into the technical aspects of the developed device. The presented results show that the angle measurement error falls within the reported values of the state-of-the-art IMU-based knee joint angle measurement devices while enabling a high-quality EMG recording over prolonged periods of time. While the device was designed and developed primarily for measuring knee activity in individuals with CP, its usability extends beyond this specific use-case scenario, making it suitable for applications that involve human joint evaluation.
format Online
Article
Text
id pubmed-10649777
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106497772023-11-03 An Integrated Approach for Real-Time Monitoring of Knee Dynamics with IMUs and Multichannel EMG Malesevic, Nebojsa Svensson, Ingrid Hägglund, Gunnar Antfolk, Christian Sensors (Basel) Article Measuring human joint dynamics is crucial for understanding how our bodies move and function, providing valuable insights into biomechanics and motor control. Cerebral palsy (CP) is a neurological disorder affecting motor control and posture, leading to diverse gait abnormalities, including altered knee angles. The accurate measurement and analysis of knee angles in individuals with CP are crucial for understanding their gait patterns, assessing treatment outcomes, and guiding interventions. This paper presents a novel multimodal approach that combines inertial measurement unit (IMU) sensors and electromyography (EMG) to measure knee angles in individuals with CP during gait and other daily activities. We discuss the performance of this integrated approach, highlighting the accuracy of IMU sensors in capturing knee joint movements when compared with an optical motion-tracking system and the complementary insights offered by EMG in assessing muscle activation patterns. Moreover, we delve into the technical aspects of the developed device. The presented results show that the angle measurement error falls within the reported values of the state-of-the-art IMU-based knee joint angle measurement devices while enabling a high-quality EMG recording over prolonged periods of time. While the device was designed and developed primarily for measuring knee activity in individuals with CP, its usability extends beyond this specific use-case scenario, making it suitable for applications that involve human joint evaluation. MDPI 2023-11-03 /pmc/articles/PMC10649777/ /pubmed/37960654 http://dx.doi.org/10.3390/s23218955 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Malesevic, Nebojsa
Svensson, Ingrid
Hägglund, Gunnar
Antfolk, Christian
An Integrated Approach for Real-Time Monitoring of Knee Dynamics with IMUs and Multichannel EMG
title An Integrated Approach for Real-Time Monitoring of Knee Dynamics with IMUs and Multichannel EMG
title_full An Integrated Approach for Real-Time Monitoring of Knee Dynamics with IMUs and Multichannel EMG
title_fullStr An Integrated Approach for Real-Time Monitoring of Knee Dynamics with IMUs and Multichannel EMG
title_full_unstemmed An Integrated Approach for Real-Time Monitoring of Knee Dynamics with IMUs and Multichannel EMG
title_short An Integrated Approach for Real-Time Monitoring of Knee Dynamics with IMUs and Multichannel EMG
title_sort integrated approach for real-time monitoring of knee dynamics with imus and multichannel emg
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649777/
https://www.ncbi.nlm.nih.gov/pubmed/37960654
http://dx.doi.org/10.3390/s23218955
work_keys_str_mv AT malesevicnebojsa anintegratedapproachforrealtimemonitoringofkneedynamicswithimusandmultichannelemg
AT svenssoningrid anintegratedapproachforrealtimemonitoringofkneedynamicswithimusandmultichannelemg
AT hagglundgunnar anintegratedapproachforrealtimemonitoringofkneedynamicswithimusandmultichannelemg
AT antfolkchristian anintegratedapproachforrealtimemonitoringofkneedynamicswithimusandmultichannelemg
AT malesevicnebojsa integratedapproachforrealtimemonitoringofkneedynamicswithimusandmultichannelemg
AT svenssoningrid integratedapproachforrealtimemonitoringofkneedynamicswithimusandmultichannelemg
AT hagglundgunnar integratedapproachforrealtimemonitoringofkneedynamicswithimusandmultichannelemg
AT antfolkchristian integratedapproachforrealtimemonitoringofkneedynamicswithimusandmultichannelemg