Cargando…
Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis
(1) Background: Percutaneous coronary interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOSs) or drug-eluting stents (DESs). The initial completion of this prospective systematic literature review (SLR) of prospective random...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649952/ https://www.ncbi.nlm.nih.gov/pubmed/37959416 http://dx.doi.org/10.3390/jcm12216952 |
_version_ | 1785135667945144320 |
---|---|
author | Daoud, Frederic C. Catargi, Bogdan Karjalainen, Pasi P. Gerbaud, Edouard |
author_facet | Daoud, Frederic C. Catargi, Bogdan Karjalainen, Pasi P. Gerbaud, Edouard |
author_sort | Daoud, Frederic C. |
collection | PubMed |
description | (1) Background: Percutaneous coronary interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOSs) or drug-eluting stents (DESs). The initial completion of this prospective systematic literature review (SLR) of prospective randomized controlled trials (RCTs) showed that TiNOSs are non-inferior to DESs in major adverse cardiac event (MACE) rates and present a lower risk of recurrent myocardial infarction (MI) at 1-year follow-up. This iteration of the SLR protocol performs the critical assessment of 5-year follow-up outcomes with clinical validity and generalizability assessments. (2) Methods: The previously described SLR and meta-analysis protocol, per PRISMA, Cochrane methods, and GRADE, was applied to 5-year follow-up outcomes. (3) Results: Three RCTs were eligible, comprising 1620 patients with TiNOS vs. 1123 with DES. The pooled risk ratios (RRs) and 95% confidence intervals were MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion revascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and all-cause mortality (TD) 0.84 [0.63, 1.12]. The evidence certainty was high in MACE, CD, MI, and ST, and moderate in TLR and TD. (4) Conclusions: TiNOSs in ACS at 5-year follow-up appear safer than DESs and equally efficacious. The pooled RRs stratified by clinical presentation and stent type will be required to test this meta-analysis’s clinical validity and generalize its results to patient populations with varying proportions of clinical presentations and DES options. |
format | Online Article Text |
id | pubmed-10649952 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106499522023-11-06 Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis Daoud, Frederic C. Catargi, Bogdan Karjalainen, Pasi P. Gerbaud, Edouard J Clin Med Systematic Review (1) Background: Percutaneous coronary interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOSs) or drug-eluting stents (DESs). The initial completion of this prospective systematic literature review (SLR) of prospective randomized controlled trials (RCTs) showed that TiNOSs are non-inferior to DESs in major adverse cardiac event (MACE) rates and present a lower risk of recurrent myocardial infarction (MI) at 1-year follow-up. This iteration of the SLR protocol performs the critical assessment of 5-year follow-up outcomes with clinical validity and generalizability assessments. (2) Methods: The previously described SLR and meta-analysis protocol, per PRISMA, Cochrane methods, and GRADE, was applied to 5-year follow-up outcomes. (3) Results: Three RCTs were eligible, comprising 1620 patients with TiNOS vs. 1123 with DES. The pooled risk ratios (RRs) and 95% confidence intervals were MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion revascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and all-cause mortality (TD) 0.84 [0.63, 1.12]. The evidence certainty was high in MACE, CD, MI, and ST, and moderate in TLR and TD. (4) Conclusions: TiNOSs in ACS at 5-year follow-up appear safer than DESs and equally efficacious. The pooled RRs stratified by clinical presentation and stent type will be required to test this meta-analysis’s clinical validity and generalize its results to patient populations with varying proportions of clinical presentations and DES options. MDPI 2023-11-06 /pmc/articles/PMC10649952/ /pubmed/37959416 http://dx.doi.org/10.3390/jcm12216952 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Systematic Review Daoud, Frederic C. Catargi, Bogdan Karjalainen, Pasi P. Gerbaud, Edouard Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis |
title | Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis |
title_full | Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis |
title_fullStr | Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis |
title_full_unstemmed | Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis |
title_short | Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis |
title_sort | five-year efficacy and safety of tino-coated stents versus drug-eluting stents in acute coronary syndrome: a meta-analysis |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649952/ https://www.ncbi.nlm.nih.gov/pubmed/37959416 http://dx.doi.org/10.3390/jcm12216952 |
work_keys_str_mv | AT daoudfredericc fiveyearefficacyandsafetyoftinocoatedstentsversusdrugelutingstentsinacutecoronarysyndromeametaanalysis AT catargibogdan fiveyearefficacyandsafetyoftinocoatedstentsversusdrugelutingstentsinacutecoronarysyndromeametaanalysis AT karjalainenpasip fiveyearefficacyandsafetyoftinocoatedstentsversusdrugelutingstentsinacutecoronarysyndromeametaanalysis AT gerbaudedouard fiveyearefficacyandsafetyoftinocoatedstentsversusdrugelutingstentsinacutecoronarysyndromeametaanalysis |