Cargando…

The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells

The oxygenation of cells and tissues and acidification of the cellular endolysosomal system are among the major factors that ensure normal functioning of an organism and are violated in various pathologies. Recording of these parameters and their changes under various conditions is an important task...

Descripción completa

Detalles Bibliográficos
Autores principales: Litvinov, Ilia K., Belyaeva, Tatiana N., Salova, Anna V., Aksenov, Nikolay D., Chelushkin, Pavel S., Solomatina, Anastasia I., Tunik, Sergey P., Kornilova, Elena S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650141/
https://www.ncbi.nlm.nih.gov/pubmed/37958592
http://dx.doi.org/10.3390/ijms242115606
_version_ 1785135712095436800
author Litvinov, Ilia K.
Belyaeva, Tatiana N.
Salova, Anna V.
Aksenov, Nikolay D.
Chelushkin, Pavel S.
Solomatina, Anastasia I.
Tunik, Sergey P.
Kornilova, Elena S.
author_facet Litvinov, Ilia K.
Belyaeva, Tatiana N.
Salova, Anna V.
Aksenov, Nikolay D.
Chelushkin, Pavel S.
Solomatina, Anastasia I.
Tunik, Sergey P.
Kornilova, Elena S.
author_sort Litvinov, Ilia K.
collection PubMed
description The oxygenation of cells and tissues and acidification of the cellular endolysosomal system are among the major factors that ensure normal functioning of an organism and are violated in various pathologies. Recording of these parameters and their changes under various conditions is an important task for both basic research and clinical applications. In the present work, we utilized internalizable dual pH/O(2) lifetime sensor (Ir-HSA-FITC) based on the covalent conjugation of human serum albumin (HSA) with fluorescein isothiocyanate (FITC) as pH sensor and an orthometalated iridium complex as O(2) sensor. The probe was tested for simultaneous detection of acidification level and oxygen concentration in endolysosomes of endometrial mesenchymal stem/stromal cells (enMSCs) cultivated as 2D monolayers and 3D spheroids. Using a combined FLIM/PLIM approach, we found that due to high autofluorescence of enMSCs FITC lifetime signal in control cells was insufficient to estimate pH changes. However, using flow cytometry and confocal microscopy, we managed to detect the FITC signal response to inhibition of endolysosomal acidification by Bafilomycin A1. The iridium chromophore phosphorescence was detected reliably by all methods used. It was demonstrated that the sensor, accumulated in endolysosomes for 24 h, disappeared from proliferating 2D enMSCs by 72 h, but can still be recorded in non-proliferating spheroids. PLIM showed high sensitivity and responsiveness of iridium chromophore phosphorescence to experimental hypoxia both in 2D and 3D cultures. In spheroids, the phosphorescence signal was detected at a depth of up to 60 μm using PLIM and showed a gradient in the intracellular O(2) level towards their center.
format Online
Article
Text
id pubmed-10650141
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106501412023-10-26 The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells Litvinov, Ilia K. Belyaeva, Tatiana N. Salova, Anna V. Aksenov, Nikolay D. Chelushkin, Pavel S. Solomatina, Anastasia I. Tunik, Sergey P. Kornilova, Elena S. Int J Mol Sci Article The oxygenation of cells and tissues and acidification of the cellular endolysosomal system are among the major factors that ensure normal functioning of an organism and are violated in various pathologies. Recording of these parameters and their changes under various conditions is an important task for both basic research and clinical applications. In the present work, we utilized internalizable dual pH/O(2) lifetime sensor (Ir-HSA-FITC) based on the covalent conjugation of human serum albumin (HSA) with fluorescein isothiocyanate (FITC) as pH sensor and an orthometalated iridium complex as O(2) sensor. The probe was tested for simultaneous detection of acidification level and oxygen concentration in endolysosomes of endometrial mesenchymal stem/stromal cells (enMSCs) cultivated as 2D monolayers and 3D spheroids. Using a combined FLIM/PLIM approach, we found that due to high autofluorescence of enMSCs FITC lifetime signal in control cells was insufficient to estimate pH changes. However, using flow cytometry and confocal microscopy, we managed to detect the FITC signal response to inhibition of endolysosomal acidification by Bafilomycin A1. The iridium chromophore phosphorescence was detected reliably by all methods used. It was demonstrated that the sensor, accumulated in endolysosomes for 24 h, disappeared from proliferating 2D enMSCs by 72 h, but can still be recorded in non-proliferating spheroids. PLIM showed high sensitivity and responsiveness of iridium chromophore phosphorescence to experimental hypoxia both in 2D and 3D cultures. In spheroids, the phosphorescence signal was detected at a depth of up to 60 μm using PLIM and showed a gradient in the intracellular O(2) level towards their center. MDPI 2023-10-26 /pmc/articles/PMC10650141/ /pubmed/37958592 http://dx.doi.org/10.3390/ijms242115606 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Litvinov, Ilia K.
Belyaeva, Tatiana N.
Salova, Anna V.
Aksenov, Nikolay D.
Chelushkin, Pavel S.
Solomatina, Anastasia I.
Tunik, Sergey P.
Kornilova, Elena S.
The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells
title The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells
title_full The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells
title_fullStr The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells
title_full_unstemmed The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells
title_short The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells
title_sort dual luminescence lifetime ph/oxygen sensor: evaluation of applicability for intravital analysis of 2d- and 3d-cultivated human endometrial mesenchymal stromal cells
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650141/
https://www.ncbi.nlm.nih.gov/pubmed/37958592
http://dx.doi.org/10.3390/ijms242115606
work_keys_str_mv AT litvinoviliak thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT belyaevatatianan thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT salovaannav thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT aksenovnikolayd thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT chelushkinpavels thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT solomatinaanastasiai thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT tuniksergeyp thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT kornilovaelenas thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT litvinoviliak dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT belyaevatatianan dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT salovaannav dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT aksenovnikolayd dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT chelushkinpavels dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT solomatinaanastasiai dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT tuniksergeyp dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells
AT kornilovaelenas dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells