Cargando…
The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells
The oxygenation of cells and tissues and acidification of the cellular endolysosomal system are among the major factors that ensure normal functioning of an organism and are violated in various pathologies. Recording of these parameters and their changes under various conditions is an important task...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650141/ https://www.ncbi.nlm.nih.gov/pubmed/37958592 http://dx.doi.org/10.3390/ijms242115606 |
_version_ | 1785135712095436800 |
---|---|
author | Litvinov, Ilia K. Belyaeva, Tatiana N. Salova, Anna V. Aksenov, Nikolay D. Chelushkin, Pavel S. Solomatina, Anastasia I. Tunik, Sergey P. Kornilova, Elena S. |
author_facet | Litvinov, Ilia K. Belyaeva, Tatiana N. Salova, Anna V. Aksenov, Nikolay D. Chelushkin, Pavel S. Solomatina, Anastasia I. Tunik, Sergey P. Kornilova, Elena S. |
author_sort | Litvinov, Ilia K. |
collection | PubMed |
description | The oxygenation of cells and tissues and acidification of the cellular endolysosomal system are among the major factors that ensure normal functioning of an organism and are violated in various pathologies. Recording of these parameters and their changes under various conditions is an important task for both basic research and clinical applications. In the present work, we utilized internalizable dual pH/O(2) lifetime sensor (Ir-HSA-FITC) based on the covalent conjugation of human serum albumin (HSA) with fluorescein isothiocyanate (FITC) as pH sensor and an orthometalated iridium complex as O(2) sensor. The probe was tested for simultaneous detection of acidification level and oxygen concentration in endolysosomes of endometrial mesenchymal stem/stromal cells (enMSCs) cultivated as 2D monolayers and 3D spheroids. Using a combined FLIM/PLIM approach, we found that due to high autofluorescence of enMSCs FITC lifetime signal in control cells was insufficient to estimate pH changes. However, using flow cytometry and confocal microscopy, we managed to detect the FITC signal response to inhibition of endolysosomal acidification by Bafilomycin A1. The iridium chromophore phosphorescence was detected reliably by all methods used. It was demonstrated that the sensor, accumulated in endolysosomes for 24 h, disappeared from proliferating 2D enMSCs by 72 h, but can still be recorded in non-proliferating spheroids. PLIM showed high sensitivity and responsiveness of iridium chromophore phosphorescence to experimental hypoxia both in 2D and 3D cultures. In spheroids, the phosphorescence signal was detected at a depth of up to 60 μm using PLIM and showed a gradient in the intracellular O(2) level towards their center. |
format | Online Article Text |
id | pubmed-10650141 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106501412023-10-26 The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells Litvinov, Ilia K. Belyaeva, Tatiana N. Salova, Anna V. Aksenov, Nikolay D. Chelushkin, Pavel S. Solomatina, Anastasia I. Tunik, Sergey P. Kornilova, Elena S. Int J Mol Sci Article The oxygenation of cells and tissues and acidification of the cellular endolysosomal system are among the major factors that ensure normal functioning of an organism and are violated in various pathologies. Recording of these parameters and their changes under various conditions is an important task for both basic research and clinical applications. In the present work, we utilized internalizable dual pH/O(2) lifetime sensor (Ir-HSA-FITC) based on the covalent conjugation of human serum albumin (HSA) with fluorescein isothiocyanate (FITC) as pH sensor and an orthometalated iridium complex as O(2) sensor. The probe was tested for simultaneous detection of acidification level and oxygen concentration in endolysosomes of endometrial mesenchymal stem/stromal cells (enMSCs) cultivated as 2D monolayers and 3D spheroids. Using a combined FLIM/PLIM approach, we found that due to high autofluorescence of enMSCs FITC lifetime signal in control cells was insufficient to estimate pH changes. However, using flow cytometry and confocal microscopy, we managed to detect the FITC signal response to inhibition of endolysosomal acidification by Bafilomycin A1. The iridium chromophore phosphorescence was detected reliably by all methods used. It was demonstrated that the sensor, accumulated in endolysosomes for 24 h, disappeared from proliferating 2D enMSCs by 72 h, but can still be recorded in non-proliferating spheroids. PLIM showed high sensitivity and responsiveness of iridium chromophore phosphorescence to experimental hypoxia both in 2D and 3D cultures. In spheroids, the phosphorescence signal was detected at a depth of up to 60 μm using PLIM and showed a gradient in the intracellular O(2) level towards their center. MDPI 2023-10-26 /pmc/articles/PMC10650141/ /pubmed/37958592 http://dx.doi.org/10.3390/ijms242115606 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Litvinov, Ilia K. Belyaeva, Tatiana N. Salova, Anna V. Aksenov, Nikolay D. Chelushkin, Pavel S. Solomatina, Anastasia I. Tunik, Sergey P. Kornilova, Elena S. The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells |
title | The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells |
title_full | The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells |
title_fullStr | The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells |
title_full_unstemmed | The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells |
title_short | The Dual Luminescence Lifetime pH/Oxygen Sensor: Evaluation of Applicability for Intravital Analysis of 2D- and 3D-Cultivated Human Endometrial Mesenchymal Stromal Cells |
title_sort | dual luminescence lifetime ph/oxygen sensor: evaluation of applicability for intravital analysis of 2d- and 3d-cultivated human endometrial mesenchymal stromal cells |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650141/ https://www.ncbi.nlm.nih.gov/pubmed/37958592 http://dx.doi.org/10.3390/ijms242115606 |
work_keys_str_mv | AT litvinoviliak thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT belyaevatatianan thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT salovaannav thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT aksenovnikolayd thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT chelushkinpavels thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT solomatinaanastasiai thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT tuniksergeyp thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT kornilovaelenas thedualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT litvinoviliak dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT belyaevatatianan dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT salovaannav dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT aksenovnikolayd dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT chelushkinpavels dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT solomatinaanastasiai dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT tuniksergeyp dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells AT kornilovaelenas dualluminescencelifetimephoxygensensorevaluationofapplicabilityforintravitalanalysisof2dand3dcultivatedhumanendometrialmesenchymalstromalcells |