Cargando…

Differences in Mechanical, Electrical and Calcium Transient Performance of the Isolated Right Atrial and Ventricular Myocardium of Guinea Pigs at Different Preloads (Lengths)

There are only a few studies devoted to the comparative and simultaneous study of the mechanisms of the length-dependent regulation of atrial and ventricular contractility. Therefore, an isometric force-length protocol was applied to isolated guinea pig right atrial (RA) strips and ventricular (RV)...

Descripción completa

Detalles Bibliográficos
Autores principales: Lisin, Ruslan, Balakin, Alexandr, Mukhlynina, Elena, Protsenko, Yuri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650485/
https://www.ncbi.nlm.nih.gov/pubmed/37958508
http://dx.doi.org/10.3390/ijms242115524
_version_ 1785135790995537920
author Lisin, Ruslan
Balakin, Alexandr
Mukhlynina, Elena
Protsenko, Yuri
author_facet Lisin, Ruslan
Balakin, Alexandr
Mukhlynina, Elena
Protsenko, Yuri
author_sort Lisin, Ruslan
collection PubMed
description There are only a few studies devoted to the comparative and simultaneous study of the mechanisms of the length-dependent regulation of atrial and ventricular contractility. Therefore, an isometric force-length protocol was applied to isolated guinea pig right atrial (RA) strips and ventricular (RV) trabeculae, with a simultaneous measurement of force (Frank–Starling mechanism) and Ca(2+) transients (CaT) or transmembrane action potentials (AP). Over the entire length-range studied, the duration of isometric contraction, CaT and AP, were shorter in the RA myocardium than in the RV myocardium. The RA myocardium was stiffer than the RV myocardium. With the increasing length of the RA and RV myocardium, the amplitude and duration of isometric contraction and CaT increased, as well as the amplitude and area of the “CaT difference curves” (shown for the first time). However, the rates of the tension development and relaxation decreased. No contribution of AP duration to the heterometric regulation of isometric tension was found in either the RA or RV myocardium of the guinea pig. Changes in the degree of overlap of the contractile proteins of the guinea pig RA and RV myocardium mainly affect CaT kinetics but not AP duration.
format Online
Article
Text
id pubmed-10650485
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106504852023-10-24 Differences in Mechanical, Electrical and Calcium Transient Performance of the Isolated Right Atrial and Ventricular Myocardium of Guinea Pigs at Different Preloads (Lengths) Lisin, Ruslan Balakin, Alexandr Mukhlynina, Elena Protsenko, Yuri Int J Mol Sci Article There are only a few studies devoted to the comparative and simultaneous study of the mechanisms of the length-dependent regulation of atrial and ventricular contractility. Therefore, an isometric force-length protocol was applied to isolated guinea pig right atrial (RA) strips and ventricular (RV) trabeculae, with a simultaneous measurement of force (Frank–Starling mechanism) and Ca(2+) transients (CaT) or transmembrane action potentials (AP). Over the entire length-range studied, the duration of isometric contraction, CaT and AP, were shorter in the RA myocardium than in the RV myocardium. The RA myocardium was stiffer than the RV myocardium. With the increasing length of the RA and RV myocardium, the amplitude and duration of isometric contraction and CaT increased, as well as the amplitude and area of the “CaT difference curves” (shown for the first time). However, the rates of the tension development and relaxation decreased. No contribution of AP duration to the heterometric regulation of isometric tension was found in either the RA or RV myocardium of the guinea pig. Changes in the degree of overlap of the contractile proteins of the guinea pig RA and RV myocardium mainly affect CaT kinetics but not AP duration. MDPI 2023-10-24 /pmc/articles/PMC10650485/ /pubmed/37958508 http://dx.doi.org/10.3390/ijms242115524 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lisin, Ruslan
Balakin, Alexandr
Mukhlynina, Elena
Protsenko, Yuri
Differences in Mechanical, Electrical and Calcium Transient Performance of the Isolated Right Atrial and Ventricular Myocardium of Guinea Pigs at Different Preloads (Lengths)
title Differences in Mechanical, Electrical and Calcium Transient Performance of the Isolated Right Atrial and Ventricular Myocardium of Guinea Pigs at Different Preloads (Lengths)
title_full Differences in Mechanical, Electrical and Calcium Transient Performance of the Isolated Right Atrial and Ventricular Myocardium of Guinea Pigs at Different Preloads (Lengths)
title_fullStr Differences in Mechanical, Electrical and Calcium Transient Performance of the Isolated Right Atrial and Ventricular Myocardium of Guinea Pigs at Different Preloads (Lengths)
title_full_unstemmed Differences in Mechanical, Electrical and Calcium Transient Performance of the Isolated Right Atrial and Ventricular Myocardium of Guinea Pigs at Different Preloads (Lengths)
title_short Differences in Mechanical, Electrical and Calcium Transient Performance of the Isolated Right Atrial and Ventricular Myocardium of Guinea Pigs at Different Preloads (Lengths)
title_sort differences in mechanical, electrical and calcium transient performance of the isolated right atrial and ventricular myocardium of guinea pigs at different preloads (lengths)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650485/
https://www.ncbi.nlm.nih.gov/pubmed/37958508
http://dx.doi.org/10.3390/ijms242115524
work_keys_str_mv AT lisinruslan differencesinmechanicalelectricalandcalciumtransientperformanceoftheisolatedrightatrialandventricularmyocardiumofguineapigsatdifferentpreloadslengths
AT balakinalexandr differencesinmechanicalelectricalandcalciumtransientperformanceoftheisolatedrightatrialandventricularmyocardiumofguineapigsatdifferentpreloadslengths
AT mukhlyninaelena differencesinmechanicalelectricalandcalciumtransientperformanceoftheisolatedrightatrialandventricularmyocardiumofguineapigsatdifferentpreloadslengths
AT protsenkoyuri differencesinmechanicalelectricalandcalciumtransientperformanceoftheisolatedrightatrialandventricularmyocardiumofguineapigsatdifferentpreloadslengths