Cargando…

Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial

Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs w...

Descripción completa

Detalles Bibliográficos
Autores principales: Jacques, Jérémie, Neuhaus, Horst, Enderle, Markus D., Biber, Ulrich, Linzenbold, Walter, Schenk, Martin, Khalaf, Kareem, Repici, Alessandro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650536/
https://www.ncbi.nlm.nih.gov/pubmed/37958243
http://dx.doi.org/10.3390/diagnostics13213347
_version_ 1785135802936721408
author Jacques, Jérémie
Neuhaus, Horst
Enderle, Markus D.
Biber, Ulrich
Linzenbold, Walter
Schenk, Martin
Khalaf, Kareem
Repici, Alessandro
author_facet Jacques, Jérémie
Neuhaus, Horst
Enderle, Markus D.
Biber, Ulrich
Linzenbold, Walter
Schenk, Martin
Khalaf, Kareem
Repici, Alessandro
author_sort Jacques, Jérémie
collection PubMed
description Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60–65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife(®) flex T-Type (HK-T) and the Olympus DualKnife(®) J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified.
format Online
Article
Text
id pubmed-10650536
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106505362023-10-30 Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial Jacques, Jérémie Neuhaus, Horst Enderle, Markus D. Biber, Ulrich Linzenbold, Walter Schenk, Martin Khalaf, Kareem Repici, Alessandro Diagnostics (Basel) Article Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60–65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife(®) flex T-Type (HK-T) and the Olympus DualKnife(®) J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified. MDPI 2023-10-30 /pmc/articles/PMC10650536/ /pubmed/37958243 http://dx.doi.org/10.3390/diagnostics13213347 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jacques, Jérémie
Neuhaus, Horst
Enderle, Markus D.
Biber, Ulrich
Linzenbold, Walter
Schenk, Martin
Khalaf, Kareem
Repici, Alessandro
Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial
title Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial
title_full Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial
title_fullStr Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial
title_full_unstemmed Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial
title_short Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial
title_sort colorectal endoscopic submucosal dissection: performance of a novel hybrid-technology knife in an animal trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650536/
https://www.ncbi.nlm.nih.gov/pubmed/37958243
http://dx.doi.org/10.3390/diagnostics13213347
work_keys_str_mv AT jacquesjeremie colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial
AT neuhaushorst colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial
AT enderlemarkusd colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial
AT biberulrich colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial
AT linzenboldwalter colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial
AT schenkmartin colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial
AT khalafkareem colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial
AT repicialessandro colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial