Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial
Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs w...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650536/ https://www.ncbi.nlm.nih.gov/pubmed/37958243 http://dx.doi.org/10.3390/diagnostics13213347 |
_version_ | 1785135802936721408 |
---|---|
author | Jacques, Jérémie Neuhaus, Horst Enderle, Markus D. Biber, Ulrich Linzenbold, Walter Schenk, Martin Khalaf, Kareem Repici, Alessandro |
author_facet | Jacques, Jérémie Neuhaus, Horst Enderle, Markus D. Biber, Ulrich Linzenbold, Walter Schenk, Martin Khalaf, Kareem Repici, Alessandro |
author_sort | Jacques, Jérémie |
collection | PubMed |
description | Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60–65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife(®) flex T-Type (HK-T) and the Olympus DualKnife(®) J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified. |
format | Online Article Text |
id | pubmed-10650536 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106505362023-10-30 Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial Jacques, Jérémie Neuhaus, Horst Enderle, Markus D. Biber, Ulrich Linzenbold, Walter Schenk, Martin Khalaf, Kareem Repici, Alessandro Diagnostics (Basel) Article Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60–65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife(®) flex T-Type (HK-T) and the Olympus DualKnife(®) J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified. MDPI 2023-10-30 /pmc/articles/PMC10650536/ /pubmed/37958243 http://dx.doi.org/10.3390/diagnostics13213347 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jacques, Jérémie Neuhaus, Horst Enderle, Markus D. Biber, Ulrich Linzenbold, Walter Schenk, Martin Khalaf, Kareem Repici, Alessandro Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial |
title | Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial |
title_full | Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial |
title_fullStr | Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial |
title_full_unstemmed | Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial |
title_short | Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial |
title_sort | colorectal endoscopic submucosal dissection: performance of a novel hybrid-technology knife in an animal trial |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10650536/ https://www.ncbi.nlm.nih.gov/pubmed/37958243 http://dx.doi.org/10.3390/diagnostics13213347 |
work_keys_str_mv | AT jacquesjeremie colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial AT neuhaushorst colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial AT enderlemarkusd colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial AT biberulrich colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial AT linzenboldwalter colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial AT schenkmartin colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial AT khalafkareem colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial AT repicialessandro colorectalendoscopicsubmucosaldissectionperformanceofanovelhybridtechnologyknifeinananimaltrial |