Cargando…

Optical crosstalk and other forms of light interference in pulse oximeter comparison studies

Purpose: Pulse oximeter accuracy is important for the quality and safety of patient care. Methodological errors occurring during pulse oximeter accuracy studies can confound results. One potential source of error during pulse oximeter comparison studies is optical interference due to sensor-to-senso...

Descripción completa

Detalles Bibliográficos
Autor principal: Kyriacou, Panicos A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10651698/
https://www.ncbi.nlm.nih.gov/pubmed/37610524
http://dx.doi.org/10.1007/s10877-023-01060-y
_version_ 1785136048601300992
author Kyriacou, Panicos A.
author_facet Kyriacou, Panicos A.
author_sort Kyriacou, Panicos A.
collection PubMed
description Purpose: Pulse oximeter accuracy is important for the quality and safety of patient care. Methodological errors occurring during pulse oximeter accuracy studies can confound results. One potential source of error during pulse oximeter comparison studies is optical interference due to sensor-to-sensor crosstalk. Optical crosstalk can occur whenever pulse oximeter sensors are tested in close proximity of one another, as occurs during pulse oximeter comparison studies. Methods: This publication represents the first comprehensive review of sensor-to-sensor crosstalk and other forms of optical interference during pulse oximeter comparison studies. A review of the published literature was undertaken to elucidate the mechanism of optical crosstalk, along with other forms of optical interference, and a solution (shielding) is offered. Results: When pulse oximeter sensors are placed close to each other, as occurs during comparison studies, the red and near-infrared light used can also enter an adjacent sensor and lead to error. Pulse oximeter manufacturers have designed systems to reject some forms of optical interference, such as ambient light. However, light emanating from adjacent sensors during comparison studies can cause artifact, and this can be exacerbated by sensor malposition. Proper sensor placement and use of optical shielding are the best solutions to prevent crosstalk. Conclusions: Crosstalk and other forms of optical interference can corrupt pulse oximeter readings. Proper sensor placement and use of optical shielding of sensors are crucial steps to help protect the integrity of the data. Studies to further characterize crosstalk during pulse oximeter comparison studies are needed.
format Online
Article
Text
id pubmed-10651698
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-106516982023-08-23 Optical crosstalk and other forms of light interference in pulse oximeter comparison studies Kyriacou, Panicos A. J Clin Monit Comput Review Purpose: Pulse oximeter accuracy is important for the quality and safety of patient care. Methodological errors occurring during pulse oximeter accuracy studies can confound results. One potential source of error during pulse oximeter comparison studies is optical interference due to sensor-to-sensor crosstalk. Optical crosstalk can occur whenever pulse oximeter sensors are tested in close proximity of one another, as occurs during pulse oximeter comparison studies. Methods: This publication represents the first comprehensive review of sensor-to-sensor crosstalk and other forms of optical interference during pulse oximeter comparison studies. A review of the published literature was undertaken to elucidate the mechanism of optical crosstalk, along with other forms of optical interference, and a solution (shielding) is offered. Results: When pulse oximeter sensors are placed close to each other, as occurs during comparison studies, the red and near-infrared light used can also enter an adjacent sensor and lead to error. Pulse oximeter manufacturers have designed systems to reject some forms of optical interference, such as ambient light. However, light emanating from adjacent sensors during comparison studies can cause artifact, and this can be exacerbated by sensor malposition. Proper sensor placement and use of optical shielding are the best solutions to prevent crosstalk. Conclusions: Crosstalk and other forms of optical interference can corrupt pulse oximeter readings. Proper sensor placement and use of optical shielding of sensors are crucial steps to help protect the integrity of the data. Studies to further characterize crosstalk during pulse oximeter comparison studies are needed. Springer Netherlands 2023-08-23 2023 /pmc/articles/PMC10651698/ /pubmed/37610524 http://dx.doi.org/10.1007/s10877-023-01060-y Text en © The Author(s) 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Review
Kyriacou, Panicos A.
Optical crosstalk and other forms of light interference in pulse oximeter comparison studies
title Optical crosstalk and other forms of light interference in pulse oximeter comparison studies
title_full Optical crosstalk and other forms of light interference in pulse oximeter comparison studies
title_fullStr Optical crosstalk and other forms of light interference in pulse oximeter comparison studies
title_full_unstemmed Optical crosstalk and other forms of light interference in pulse oximeter comparison studies
title_short Optical crosstalk and other forms of light interference in pulse oximeter comparison studies
title_sort optical crosstalk and other forms of light interference in pulse oximeter comparison studies
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10651698/
https://www.ncbi.nlm.nih.gov/pubmed/37610524
http://dx.doi.org/10.1007/s10877-023-01060-y
work_keys_str_mv AT kyriacoupanicosa opticalcrosstalkandotherformsoflightinterferenceinpulseoximetercomparisonstudies