Cargando…

Ultra-High-Resolution Time-of-Flight MR-Angiography for the Noninvasive Assessment of Intracranial Aneurysms, Alternative to Preinterventional DSA?

PURPOSE: The 3D time-of-flight (TOF) magnetic resonance angiography (MRA) at 3T shows high sensitivity for intracranial aneurysms but is inferior to three-dimensional digital subtraction angiography (3D-DSA) regarding aneurysm characteristics. We applied an ultra-high-resolution (UHR) TOF-MRA using...

Descripción completa

Detalles Bibliográficos
Autores principales: Schubert, Tilman, Husain, Hakim Shakir, Thurner, Patrick, Madjidyar, Jawid, Barnaure, Isabelle, Piccirelli, Marco, Klarhöfer, Markus, Schmidt, Michaela, Speier, Peter, Forman, Christoph, Kulcsar, Zsolt
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10654166/
https://www.ncbi.nlm.nih.gov/pubmed/37401949
http://dx.doi.org/10.1007/s00062-023-01320-z
_version_ 1785136569702678528
author Schubert, Tilman
Husain, Hakim Shakir
Thurner, Patrick
Madjidyar, Jawid
Barnaure, Isabelle
Piccirelli, Marco
Klarhöfer, Markus
Schmidt, Michaela
Speier, Peter
Forman, Christoph
Kulcsar, Zsolt
author_facet Schubert, Tilman
Husain, Hakim Shakir
Thurner, Patrick
Madjidyar, Jawid
Barnaure, Isabelle
Piccirelli, Marco
Klarhöfer, Markus
Schmidt, Michaela
Speier, Peter
Forman, Christoph
Kulcsar, Zsolt
author_sort Schubert, Tilman
collection PubMed
description PURPOSE: The 3D time-of-flight (TOF) magnetic resonance angiography (MRA) at 3T shows high sensitivity for intracranial aneurysms but is inferior to three-dimensional digital subtraction angiography (3D-DSA) regarding aneurysm characteristics. We applied an ultra-high-resolution (UHR) TOF-MRA using compressed sensing reconstruction to investigate the diagnostic performance in preinterventional evaluation of intracranial aneurysms compared to conventional TOF-MRA and 3D-DSA. METHODS: In this study 17 patients with unruptured intracranial aneurysms were included. Aneurysm dimensions, configuration, image quality and sizing of endovascular devices were compared between conventional TOF-MRA at 3T and UHR-TOF with 3D-DSA as gold standard. Quantitatively, contrast-to-noise ratios (CNR) were compared between TOF-MRAs. RESULTS: On 3D-DSA, 25 aneurysms in 17 patients were detected. On conventional TOF, 23 aneurysms were detected (sensitivity: 92.6%). On UHR-TOF, 25 aneurysms were detected (sensitivity: 100%). Image quality was not significantly different between TOF and UHR-TOF (p = 0.17). Aneurysm dimension measurements were significantly different between conventional TOF (3.89 mm) and 3D-DSA (4.2 mm, p = 0.08) but not between UHR-TOF (4.12 mm) and 3D-DSA (p = 0.19). Irregularities and small vessels at the aneurysm neck were more frequently correctly depicted on UHR-TOF compared to conventional TOF. Comparison of the planned framing coil diameter and flow-diverter (FD) diameter revealed neither a statistically significant difference between TOF and 3D-DSA (coil p = 0.19, FD p = 0.45) nor between UHR-TOF and 3D-DSA (coil: p = 0.53, FD 0.33). The CNR was significantly higher in conventional TOF (p = 0.009). CONCLUSION: In this pilot study, ultra-high-resolution TOF-MRA visualized all aneurysms and accurately depicted aneurysm irregularities and vessels at the base of the aneurysm comparably to DSA, outperforming conventional TOF. UHR-TOF with compressed sensing reconstruction seems to represent a non-invasive alternative to pre-interventional DSA for intracranial aneurysms.
format Online
Article
Text
id pubmed-10654166
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-106541662023-07-04 Ultra-High-Resolution Time-of-Flight MR-Angiography for the Noninvasive Assessment of Intracranial Aneurysms, Alternative to Preinterventional DSA? Schubert, Tilman Husain, Hakim Shakir Thurner, Patrick Madjidyar, Jawid Barnaure, Isabelle Piccirelli, Marco Klarhöfer, Markus Schmidt, Michaela Speier, Peter Forman, Christoph Kulcsar, Zsolt Clin Neuroradiol Original Article PURPOSE: The 3D time-of-flight (TOF) magnetic resonance angiography (MRA) at 3T shows high sensitivity for intracranial aneurysms but is inferior to three-dimensional digital subtraction angiography (3D-DSA) regarding aneurysm characteristics. We applied an ultra-high-resolution (UHR) TOF-MRA using compressed sensing reconstruction to investigate the diagnostic performance in preinterventional evaluation of intracranial aneurysms compared to conventional TOF-MRA and 3D-DSA. METHODS: In this study 17 patients with unruptured intracranial aneurysms were included. Aneurysm dimensions, configuration, image quality and sizing of endovascular devices were compared between conventional TOF-MRA at 3T and UHR-TOF with 3D-DSA as gold standard. Quantitatively, contrast-to-noise ratios (CNR) were compared between TOF-MRAs. RESULTS: On 3D-DSA, 25 aneurysms in 17 patients were detected. On conventional TOF, 23 aneurysms were detected (sensitivity: 92.6%). On UHR-TOF, 25 aneurysms were detected (sensitivity: 100%). Image quality was not significantly different between TOF and UHR-TOF (p = 0.17). Aneurysm dimension measurements were significantly different between conventional TOF (3.89 mm) and 3D-DSA (4.2 mm, p = 0.08) but not between UHR-TOF (4.12 mm) and 3D-DSA (p = 0.19). Irregularities and small vessels at the aneurysm neck were more frequently correctly depicted on UHR-TOF compared to conventional TOF. Comparison of the planned framing coil diameter and flow-diverter (FD) diameter revealed neither a statistically significant difference between TOF and 3D-DSA (coil p = 0.19, FD p = 0.45) nor between UHR-TOF and 3D-DSA (coil: p = 0.53, FD 0.33). The CNR was significantly higher in conventional TOF (p = 0.009). CONCLUSION: In this pilot study, ultra-high-resolution TOF-MRA visualized all aneurysms and accurately depicted aneurysm irregularities and vessels at the base of the aneurysm comparably to DSA, outperforming conventional TOF. UHR-TOF with compressed sensing reconstruction seems to represent a non-invasive alternative to pre-interventional DSA for intracranial aneurysms. Springer Berlin Heidelberg 2023-07-04 2023 /pmc/articles/PMC10654166/ /pubmed/37401949 http://dx.doi.org/10.1007/s00062-023-01320-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Schubert, Tilman
Husain, Hakim Shakir
Thurner, Patrick
Madjidyar, Jawid
Barnaure, Isabelle
Piccirelli, Marco
Klarhöfer, Markus
Schmidt, Michaela
Speier, Peter
Forman, Christoph
Kulcsar, Zsolt
Ultra-High-Resolution Time-of-Flight MR-Angiography for the Noninvasive Assessment of Intracranial Aneurysms, Alternative to Preinterventional DSA?
title Ultra-High-Resolution Time-of-Flight MR-Angiography for the Noninvasive Assessment of Intracranial Aneurysms, Alternative to Preinterventional DSA?
title_full Ultra-High-Resolution Time-of-Flight MR-Angiography for the Noninvasive Assessment of Intracranial Aneurysms, Alternative to Preinterventional DSA?
title_fullStr Ultra-High-Resolution Time-of-Flight MR-Angiography for the Noninvasive Assessment of Intracranial Aneurysms, Alternative to Preinterventional DSA?
title_full_unstemmed Ultra-High-Resolution Time-of-Flight MR-Angiography for the Noninvasive Assessment of Intracranial Aneurysms, Alternative to Preinterventional DSA?
title_short Ultra-High-Resolution Time-of-Flight MR-Angiography for the Noninvasive Assessment of Intracranial Aneurysms, Alternative to Preinterventional DSA?
title_sort ultra-high-resolution time-of-flight mr-angiography for the noninvasive assessment of intracranial aneurysms, alternative to preinterventional dsa?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10654166/
https://www.ncbi.nlm.nih.gov/pubmed/37401949
http://dx.doi.org/10.1007/s00062-023-01320-z
work_keys_str_mv AT schuberttilman ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT husainhakimshakir ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT thurnerpatrick ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT madjidyarjawid ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT barnaureisabelle ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT piccirellimarco ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT klarhofermarkus ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT schmidtmichaela ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT speierpeter ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT formanchristoph ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa
AT kulcsarzsolt ultrahighresolutiontimeofflightmrangiographyforthenoninvasiveassessmentofintracranialaneurysmsalternativetopreinterventionaldsa