Cargando…

Immunofluorescence Staining for IgG Subclass: Cause for Discrepancy in the Detection of IgG1

INTRODUCTION: Immunofluorescence (IF) staining for IgG subclasses plays an important role in the classification of kidney disease. However, widely used IgG subclass-specific antibodies are now commercially unavailable. Thus, we compared alternative antibodies for performing IgG subclass staining. ME...

Descripción completa

Detalles Bibliográficos
Autores principales: Kudose, Satoru, Sekulic, Miroslav, Walavalkar, Vighnesh, Batal, Ibrahim, Stokes, M. Barry, Markowitz, Glen S., D’Agati, Vivette D., Santoriello, Dominick
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10658247/
https://www.ncbi.nlm.nih.gov/pubmed/38025244
http://dx.doi.org/10.1016/j.ekir.2023.08.015
_version_ 1785137377334788096
author Kudose, Satoru
Sekulic, Miroslav
Walavalkar, Vighnesh
Batal, Ibrahim
Stokes, M. Barry
Markowitz, Glen S.
D’Agati, Vivette D.
Santoriello, Dominick
author_facet Kudose, Satoru
Sekulic, Miroslav
Walavalkar, Vighnesh
Batal, Ibrahim
Stokes, M. Barry
Markowitz, Glen S.
D’Agati, Vivette D.
Santoriello, Dominick
author_sort Kudose, Satoru
collection PubMed
description INTRODUCTION: Immunofluorescence (IF) staining for IgG subclasses plays an important role in the classification of kidney disease. However, widely used IgG subclass-specific antibodies are now commercially unavailable. Thus, we compared alternative antibodies for performing IgG subclass staining. METHODS: A total of 21 cases were stained by 3 different methods: direct IF using fluorescein isothiocyanate (FITC)-conjugated polyclonal antibodies against IgG1-4 (commercially unavailable method), direct IF using FITC-conjugated monoclonal antibodies (clones HP-6091, 6014, 6050, and 6025), indirect IF using monoclonal antibodies (clones HP-6069, 6002, 6050, and 6025), and FITC-conjugated polyclonal secondary antibody. For cases with discrepancy in IgG1 staining, additional direct IF using FITC-conjugated monoclonal antibody (clone 4E3) was performed. RESULTS: Of 21 cases, 11 (52%) had no staining for IgG1 by direct IF using the clone HP-6091 despite ≥1+ staining by the direct IF using polyclonal antibodies. Similarly, direct IF for IgG1 using the clone 4E3 had negative result in all 10 cases with available tissue. However, indirect IF for IgG1 using the clone HP-6069 had similar staining intensity (within 1 order of magnitude) as direct IF using the polyclonal antibodies (10 of 10). Results of IF for IgG2, IgG3, and IgG4 were similar in most cases. CONCLUSION: The choice of antibodies influences the result of IgG subclass staining, especially for anti-IgG1 antibodies, in which 2 monoclonal antibodies (HP6091 and 4E3) appear less sensitive. Although this may be due to unaccounted variables and requires confirmation, our results may partially explain the difference in IgG1 staining in the literature and underscore the need for careful validation.
format Online
Article
Text
id pubmed-10658247
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106582472023-08-21 Immunofluorescence Staining for IgG Subclass: Cause for Discrepancy in the Detection of IgG1 Kudose, Satoru Sekulic, Miroslav Walavalkar, Vighnesh Batal, Ibrahim Stokes, M. Barry Markowitz, Glen S. D’Agati, Vivette D. Santoriello, Dominick Kidney Int Rep Clinical Research INTRODUCTION: Immunofluorescence (IF) staining for IgG subclasses plays an important role in the classification of kidney disease. However, widely used IgG subclass-specific antibodies are now commercially unavailable. Thus, we compared alternative antibodies for performing IgG subclass staining. METHODS: A total of 21 cases were stained by 3 different methods: direct IF using fluorescein isothiocyanate (FITC)-conjugated polyclonal antibodies against IgG1-4 (commercially unavailable method), direct IF using FITC-conjugated monoclonal antibodies (clones HP-6091, 6014, 6050, and 6025), indirect IF using monoclonal antibodies (clones HP-6069, 6002, 6050, and 6025), and FITC-conjugated polyclonal secondary antibody. For cases with discrepancy in IgG1 staining, additional direct IF using FITC-conjugated monoclonal antibody (clone 4E3) was performed. RESULTS: Of 21 cases, 11 (52%) had no staining for IgG1 by direct IF using the clone HP-6091 despite ≥1+ staining by the direct IF using polyclonal antibodies. Similarly, direct IF for IgG1 using the clone 4E3 had negative result in all 10 cases with available tissue. However, indirect IF for IgG1 using the clone HP-6069 had similar staining intensity (within 1 order of magnitude) as direct IF using the polyclonal antibodies (10 of 10). Results of IF for IgG2, IgG3, and IgG4 were similar in most cases. CONCLUSION: The choice of antibodies influences the result of IgG subclass staining, especially for anti-IgG1 antibodies, in which 2 monoclonal antibodies (HP6091 and 4E3) appear less sensitive. Although this may be due to unaccounted variables and requires confirmation, our results may partially explain the difference in IgG1 staining in the literature and underscore the need for careful validation. Elsevier 2023-08-21 /pmc/articles/PMC10658247/ /pubmed/38025244 http://dx.doi.org/10.1016/j.ekir.2023.08.015 Text en © 2023 International Society of Nephrology. Published by Elsevier Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Clinical Research
Kudose, Satoru
Sekulic, Miroslav
Walavalkar, Vighnesh
Batal, Ibrahim
Stokes, M. Barry
Markowitz, Glen S.
D’Agati, Vivette D.
Santoriello, Dominick
Immunofluorescence Staining for IgG Subclass: Cause for Discrepancy in the Detection of IgG1
title Immunofluorescence Staining for IgG Subclass: Cause for Discrepancy in the Detection of IgG1
title_full Immunofluorescence Staining for IgG Subclass: Cause for Discrepancy in the Detection of IgG1
title_fullStr Immunofluorescence Staining for IgG Subclass: Cause for Discrepancy in the Detection of IgG1
title_full_unstemmed Immunofluorescence Staining for IgG Subclass: Cause for Discrepancy in the Detection of IgG1
title_short Immunofluorescence Staining for IgG Subclass: Cause for Discrepancy in the Detection of IgG1
title_sort immunofluorescence staining for igg subclass: cause for discrepancy in the detection of igg1
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10658247/
https://www.ncbi.nlm.nih.gov/pubmed/38025244
http://dx.doi.org/10.1016/j.ekir.2023.08.015
work_keys_str_mv AT kudosesatoru immunofluorescencestainingforiggsubclasscausefordiscrepancyinthedetectionofigg1
AT sekulicmiroslav immunofluorescencestainingforiggsubclasscausefordiscrepancyinthedetectionofigg1
AT walavalkarvighnesh immunofluorescencestainingforiggsubclasscausefordiscrepancyinthedetectionofigg1
AT batalibrahim immunofluorescencestainingforiggsubclasscausefordiscrepancyinthedetectionofigg1
AT stokesmbarry immunofluorescencestainingforiggsubclasscausefordiscrepancyinthedetectionofigg1
AT markowitzglens immunofluorescencestainingforiggsubclasscausefordiscrepancyinthedetectionofigg1
AT dagativivetted immunofluorescencestainingforiggsubclasscausefordiscrepancyinthedetectionofigg1
AT santoriellodominick immunofluorescencestainingforiggsubclasscausefordiscrepancyinthedetectionofigg1