Decreased Noise and Identification of Very Low Voltage Signals Using a Novel Electrophysiology Recording System

AIMS: The interpretation of intracardiac electrograms recorded from conventional electrophysiology recording systems is frequently impacted by powerline (50/60 Hz) noise and distortion due to notch filtering. This study compares unipolar electrograms recorded simultaneously from a conventional elect...

Descripción completa

Detalles Bibliográficos
Autores principales: Kautzner, Josef, Peichl, Petr, Paamand, Rune, Carlson, Mark D
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Radcliffe Cardiology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10658352/
https://www.ncbi.nlm.nih.gov/pubmed/38023337
http://dx.doi.org/10.15420/ecr.2022.37
_version_ 1785137398791798784
author Kautzner, Josef
Peichl, Petr
Paamand, Rune
Carlson, Mark D
author_facet Kautzner, Josef
Peichl, Petr
Paamand, Rune
Carlson, Mark D
author_sort Kautzner, Josef
collection PubMed
description AIMS: The interpretation of intracardiac electrograms recorded from conventional electrophysiology recording systems is frequently impacted by powerline (50/60 Hz) noise and distortion due to notch filtering. This study compares unipolar electrograms recorded simultaneously from a conventional electrophysiology recording system and one of two 3D mapping systems (control system) with those from a novel system (ECGenius, CathVision ApS) designed to reduce noise without the need for conventional filtering. METHODS: Unipolar electrograms were recorded simultaneously from nine consecutive patients undergoing catheter ablation for AF (five patients), atrioventricular nodal re-entrant tachycardia (three patients), or ventricular tachycardia (one patient) over the course of 1 week in 2020. RESULTS: The noise spectral power of the novel system (49–51 Hz) was 6.1 ± 6.2 times lower than that of the control system. Saturation artefact following pacing (duration 97 ± 85 ms) occurred in eight control recordings and no novel system recordings (p<0.001). High frequency, low amplitude signals and fractionated electrograms apparent on unfiltered novel system unipolar recordings were not present on control recordings. Control system notch filtering obscured His bundle electrograms observable without such filtering using the novel system and induced electrogram distortion that was not present on novel system recordings. Signal saturation occurred in five of seven control system recordings but none of the novel system recordings. CONCLUSION: In this study, novel system recordings exhibited less noise and fewer signal artefacts than the conventional control system and did not require notch filtering that distorted electrograms on control recordings. The novel recording system provided superior electrogram data not apparent with conventional systems.
format Online
Article
Text
id pubmed-10658352
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Radcliffe Cardiology
record_format MEDLINE/PubMed
spelling pubmed-106583522023-10-31 Decreased Noise and Identification of Very Low Voltage Signals Using a Novel Electrophysiology Recording System Kautzner, Josef Peichl, Petr Paamand, Rune Carlson, Mark D Eur Cardiol Arrhythmias AIMS: The interpretation of intracardiac electrograms recorded from conventional electrophysiology recording systems is frequently impacted by powerline (50/60 Hz) noise and distortion due to notch filtering. This study compares unipolar electrograms recorded simultaneously from a conventional electrophysiology recording system and one of two 3D mapping systems (control system) with those from a novel system (ECGenius, CathVision ApS) designed to reduce noise without the need for conventional filtering. METHODS: Unipolar electrograms were recorded simultaneously from nine consecutive patients undergoing catheter ablation for AF (five patients), atrioventricular nodal re-entrant tachycardia (three patients), or ventricular tachycardia (one patient) over the course of 1 week in 2020. RESULTS: The noise spectral power of the novel system (49–51 Hz) was 6.1 ± 6.2 times lower than that of the control system. Saturation artefact following pacing (duration 97 ± 85 ms) occurred in eight control recordings and no novel system recordings (p<0.001). High frequency, low amplitude signals and fractionated electrograms apparent on unfiltered novel system unipolar recordings were not present on control recordings. Control system notch filtering obscured His bundle electrograms observable without such filtering using the novel system and induced electrogram distortion that was not present on novel system recordings. Signal saturation occurred in five of seven control system recordings but none of the novel system recordings. CONCLUSION: In this study, novel system recordings exhibited less noise and fewer signal artefacts than the conventional control system and did not require notch filtering that distorted electrograms on control recordings. The novel recording system provided superior electrogram data not apparent with conventional systems. Radcliffe Cardiology 2023-10-31 /pmc/articles/PMC10658352/ /pubmed/38023337 http://dx.doi.org/10.15420/ecr.2022.37 Text en Copyright © The Author(s), 2023. Published by Radcliffe Group Ltd. https://creativecommons.org/licenses/by-nc/4.0/This work is open access under the CC-BY-NC 4.0 License which allows users to copy, redistribute and make derivative works for non-commercial purposes, provided the original work is cited correctly.
spellingShingle Arrhythmias
Kautzner, Josef
Peichl, Petr
Paamand, Rune
Carlson, Mark D
Decreased Noise and Identification of Very Low Voltage Signals Using a Novel Electrophysiology Recording System
title Decreased Noise and Identification of Very Low Voltage Signals Using a Novel Electrophysiology Recording System
title_full Decreased Noise and Identification of Very Low Voltage Signals Using a Novel Electrophysiology Recording System
title_fullStr Decreased Noise and Identification of Very Low Voltage Signals Using a Novel Electrophysiology Recording System
title_full_unstemmed Decreased Noise and Identification of Very Low Voltage Signals Using a Novel Electrophysiology Recording System
title_short Decreased Noise and Identification of Very Low Voltage Signals Using a Novel Electrophysiology Recording System
title_sort decreased noise and identification of very low voltage signals using a novel electrophysiology recording system
topic Arrhythmias
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10658352/
https://www.ncbi.nlm.nih.gov/pubmed/38023337
http://dx.doi.org/10.15420/ecr.2022.37
work_keys_str_mv AT kautznerjosef decreasednoiseandidentificationofverylowvoltagesignalsusinganovelelectrophysiologyrecordingsystem
AT peichlpetr decreasednoiseandidentificationofverylowvoltagesignalsusinganovelelectrophysiologyrecordingsystem
AT paamandrune decreasednoiseandidentificationofverylowvoltagesignalsusinganovelelectrophysiologyrecordingsystem
AT carlsonmarkd decreasednoiseandidentificationofverylowvoltagesignalsusinganovelelectrophysiologyrecordingsystem