False-positive diagnoses of damaged breast implants on imaging: a report of two cases

BACKGROUND: Silicone breast implants (SBIs), used in breast reconstruction, are durable and resistant to breakage and internal gel leakage. However, regular imaging examinations are crucial, as symptoms may not be apparent even if the implant ruptures. There are several known imaging findings that s...

Descripción completa

Detalles Bibliográficos
Autores principales: Shimabukuro, Makoto, Ishii, Naohiro, Ko, Takanori, Ohta, Tomoyuki, Matsuzaki, Kyoichi, Kishi, Kazuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10660183/
https://www.ncbi.nlm.nih.gov/pubmed/38021200
http://dx.doi.org/10.21037/gs-23-255
_version_ 1785137707298586624
author Shimabukuro, Makoto
Ishii, Naohiro
Ko, Takanori
Ohta, Tomoyuki
Matsuzaki, Kyoichi
Kishi, Kazuo
author_facet Shimabukuro, Makoto
Ishii, Naohiro
Ko, Takanori
Ohta, Tomoyuki
Matsuzaki, Kyoichi
Kishi, Kazuo
author_sort Shimabukuro, Makoto
collection PubMed
description BACKGROUND: Silicone breast implants (SBIs), used in breast reconstruction, are durable and resistant to breakage and internal gel leakage. However, regular imaging examinations are crucial, as symptoms may not be apparent even if the implant ruptures. There are several known imaging findings that suggest SBI failure. Although artifacts such as moisture and air bubbles or substances similar to the gel extending outside the shell may appear on imaging, no reports have demonstrated false-positive diagnoses of damaged SBIs in detail. Hence, we present two cases in which failure was suspected based on the imaging results but not confirmed. CASE DESCRIPTION: In case 1, at the 4-year follow-up after implant-based breast reconstruction, ultrasonography revealed a stepladder sign, and magnetic resonance imaging (MRI) revealed the salad oil sign. Although SBI failure was suggested, intraoperative examination revealed only a small amount of fluid retention within the capsule and no SBI fractures. Consequently, the imaging results were proved to be artifacts. In case 2, at the 7-year follow-up after implant-based breast reconstruction, ultrasonography revealed a subcapsular line sign, and MRI confirmed a keyhole sign. Although SBI failure was suggested, intraoperative examination revealed no implant fractures. Hematogenous serous effusion was found within the capsule, and blood clots and a large amount of fibrinous mass were found deposited at the bottom of the capsule. These findings caused false-positive diagnoses on imaging. CONCLUSIONS: In cases of suspected fractures, patients may opt for either observation or surgical removal, or replacement of the implant. When choosing the latter, it is important to inform patients of the possibility of an unbroken implant.
format Online
Article
Text
id pubmed-10660183
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-106601832023-10-30 False-positive diagnoses of damaged breast implants on imaging: a report of two cases Shimabukuro, Makoto Ishii, Naohiro Ko, Takanori Ohta, Tomoyuki Matsuzaki, Kyoichi Kishi, Kazuo Gland Surg Case Report BACKGROUND: Silicone breast implants (SBIs), used in breast reconstruction, are durable and resistant to breakage and internal gel leakage. However, regular imaging examinations are crucial, as symptoms may not be apparent even if the implant ruptures. There are several known imaging findings that suggest SBI failure. Although artifacts such as moisture and air bubbles or substances similar to the gel extending outside the shell may appear on imaging, no reports have demonstrated false-positive diagnoses of damaged SBIs in detail. Hence, we present two cases in which failure was suspected based on the imaging results but not confirmed. CASE DESCRIPTION: In case 1, at the 4-year follow-up after implant-based breast reconstruction, ultrasonography revealed a stepladder sign, and magnetic resonance imaging (MRI) revealed the salad oil sign. Although SBI failure was suggested, intraoperative examination revealed only a small amount of fluid retention within the capsule and no SBI fractures. Consequently, the imaging results were proved to be artifacts. In case 2, at the 7-year follow-up after implant-based breast reconstruction, ultrasonography revealed a subcapsular line sign, and MRI confirmed a keyhole sign. Although SBI failure was suggested, intraoperative examination revealed no implant fractures. Hematogenous serous effusion was found within the capsule, and blood clots and a large amount of fibrinous mass were found deposited at the bottom of the capsule. These findings caused false-positive diagnoses on imaging. CONCLUSIONS: In cases of suspected fractures, patients may opt for either observation or surgical removal, or replacement of the implant. When choosing the latter, it is important to inform patients of the possibility of an unbroken implant. AME Publishing Company 2023-10-26 2023-10-30 /pmc/articles/PMC10660183/ /pubmed/38021200 http://dx.doi.org/10.21037/gs-23-255 Text en 2023 Gland Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Case Report
Shimabukuro, Makoto
Ishii, Naohiro
Ko, Takanori
Ohta, Tomoyuki
Matsuzaki, Kyoichi
Kishi, Kazuo
False-positive diagnoses of damaged breast implants on imaging: a report of two cases
title False-positive diagnoses of damaged breast implants on imaging: a report of two cases
title_full False-positive diagnoses of damaged breast implants on imaging: a report of two cases
title_fullStr False-positive diagnoses of damaged breast implants on imaging: a report of two cases
title_full_unstemmed False-positive diagnoses of damaged breast implants on imaging: a report of two cases
title_short False-positive diagnoses of damaged breast implants on imaging: a report of two cases
title_sort false-positive diagnoses of damaged breast implants on imaging: a report of two cases
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10660183/
https://www.ncbi.nlm.nih.gov/pubmed/38021200
http://dx.doi.org/10.21037/gs-23-255
work_keys_str_mv AT shimabukuromakoto falsepositivediagnosesofdamagedbreastimplantsonimagingareportoftwocases
AT ishiinaohiro falsepositivediagnosesofdamagedbreastimplantsonimagingareportoftwocases
AT kotakanori falsepositivediagnosesofdamagedbreastimplantsonimagingareportoftwocases
AT ohtatomoyuki falsepositivediagnosesofdamagedbreastimplantsonimagingareportoftwocases
AT matsuzakikyoichi falsepositivediagnosesofdamagedbreastimplantsonimagingareportoftwocases
AT kishikazuo falsepositivediagnosesofdamagedbreastimplantsonimagingareportoftwocases