Comparison of percutaneous vertebroplasty and conservative treatment for one level thoracolumbar osteoporotic compression fracture in a 3-year study
The efficacy of Mesh optimized versus standard percutaneous vertebroplasty (PVP) for osteoporotic vertebral compression fractures. Grid optimization (102 cases; 38 men, 64 women aged 67.3 ± 8.5) and traditional PVP groups (94 cases) were identified from 196 PVP patients treated from May 2016 to 2019...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10661551/ https://www.ncbi.nlm.nih.gov/pubmed/37985672 http://dx.doi.org/10.1038/s41598-023-36905-8 |
_version_ | 1785148470092365824 |
---|---|
author | Xie, Yanchun Gu, Hongwen Wei, Yongcun Xuan, Anwu Yu, Hailong |
author_facet | Xie, Yanchun Gu, Hongwen Wei, Yongcun Xuan, Anwu Yu, Hailong |
author_sort | Xie, Yanchun |
collection | PubMed |
description | The efficacy of Mesh optimized versus standard percutaneous vertebroplasty (PVP) for osteoporotic vertebral compression fractures. Grid optimization (102 cases; 38 men, 64 women aged 67.3 ± 8.5) and traditional PVP groups (94 cases) were identified from 196 PVP patients treated from May 2016 to 2019. The optimal puncture site and angle forced bone cement into both groups before surgery. The main indexes were operation time, X-ray fluoroscopy times, bone cement injection volume, leakage, VAS, and injured vertebrae height. Preoperative general data were equivalent between groups (P > 0.05). All patients survived surgery without spinal cord injury, incision infection, pulmonary embolism, or death. The mesh optimization group had improved operation time (34.8 ± 6.5 min), fluoroscopy times (29.5 ± 5.5), bone cement injection volume (5.3 ± 2.1 ml), and bone cement permeability greater (3.9 percent; 4/98) than the standard PVP group (P < 0.05). Similarly, the grid optimization group had superior VAS scores (1.1 ± 0.6; 1.0 ± 0.3; and 0.9 ± 0.2) than the standard PVP group at 3 days, 3 months, and the last follow-up visit (P < 0.05). On day three after surgery, both had similar heights of injured vertebra's anterior and middle edges (P > 0.05). However, in the mesh optimization group, measurements improved to 1.8 ± 0.4 mm and (1.8 ± 0.3) mm by month three and to 1.7 ± 0.3 mm at last follow-up (P < 0.05). Mesh-optimized PVP with a mesh locator treats osteoporotic vertebral compression fractures more safely and effectively than regular PVP. |
format | Online Article Text |
id | pubmed-10661551 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-106615512023-11-20 Comparison of percutaneous vertebroplasty and conservative treatment for one level thoracolumbar osteoporotic compression fracture in a 3-year study Xie, Yanchun Gu, Hongwen Wei, Yongcun Xuan, Anwu Yu, Hailong Sci Rep Article The efficacy of Mesh optimized versus standard percutaneous vertebroplasty (PVP) for osteoporotic vertebral compression fractures. Grid optimization (102 cases; 38 men, 64 women aged 67.3 ± 8.5) and traditional PVP groups (94 cases) were identified from 196 PVP patients treated from May 2016 to 2019. The optimal puncture site and angle forced bone cement into both groups before surgery. The main indexes were operation time, X-ray fluoroscopy times, bone cement injection volume, leakage, VAS, and injured vertebrae height. Preoperative general data were equivalent between groups (P > 0.05). All patients survived surgery without spinal cord injury, incision infection, pulmonary embolism, or death. The mesh optimization group had improved operation time (34.8 ± 6.5 min), fluoroscopy times (29.5 ± 5.5), bone cement injection volume (5.3 ± 2.1 ml), and bone cement permeability greater (3.9 percent; 4/98) than the standard PVP group (P < 0.05). Similarly, the grid optimization group had superior VAS scores (1.1 ± 0.6; 1.0 ± 0.3; and 0.9 ± 0.2) than the standard PVP group at 3 days, 3 months, and the last follow-up visit (P < 0.05). On day three after surgery, both had similar heights of injured vertebra's anterior and middle edges (P > 0.05). However, in the mesh optimization group, measurements improved to 1.8 ± 0.4 mm and (1.8 ± 0.3) mm by month three and to 1.7 ± 0.3 mm at last follow-up (P < 0.05). Mesh-optimized PVP with a mesh locator treats osteoporotic vertebral compression fractures more safely and effectively than regular PVP. Nature Publishing Group UK 2023-11-20 /pmc/articles/PMC10661551/ /pubmed/37985672 http://dx.doi.org/10.1038/s41598-023-36905-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Xie, Yanchun Gu, Hongwen Wei, Yongcun Xuan, Anwu Yu, Hailong Comparison of percutaneous vertebroplasty and conservative treatment for one level thoracolumbar osteoporotic compression fracture in a 3-year study |
title | Comparison of percutaneous vertebroplasty and conservative treatment for one level thoracolumbar osteoporotic compression fracture in a 3-year study |
title_full | Comparison of percutaneous vertebroplasty and conservative treatment for one level thoracolumbar osteoporotic compression fracture in a 3-year study |
title_fullStr | Comparison of percutaneous vertebroplasty and conservative treatment for one level thoracolumbar osteoporotic compression fracture in a 3-year study |
title_full_unstemmed | Comparison of percutaneous vertebroplasty and conservative treatment for one level thoracolumbar osteoporotic compression fracture in a 3-year study |
title_short | Comparison of percutaneous vertebroplasty and conservative treatment for one level thoracolumbar osteoporotic compression fracture in a 3-year study |
title_sort | comparison of percutaneous vertebroplasty and conservative treatment for one level thoracolumbar osteoporotic compression fracture in a 3-year study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10661551/ https://www.ncbi.nlm.nih.gov/pubmed/37985672 http://dx.doi.org/10.1038/s41598-023-36905-8 |
work_keys_str_mv | AT xieyanchun comparisonofpercutaneousvertebroplastyandconservativetreatmentforonelevelthoracolumbarosteoporoticcompressionfractureina3yearstudy AT guhongwen comparisonofpercutaneousvertebroplastyandconservativetreatmentforonelevelthoracolumbarosteoporoticcompressionfractureina3yearstudy AT weiyongcun comparisonofpercutaneousvertebroplastyandconservativetreatmentforonelevelthoracolumbarosteoporoticcompressionfractureina3yearstudy AT xuananwu comparisonofpercutaneousvertebroplastyandconservativetreatmentforonelevelthoracolumbarosteoporoticcompressionfractureina3yearstudy AT yuhailong comparisonofpercutaneousvertebroplastyandconservativetreatmentforonelevelthoracolumbarosteoporoticcompressionfractureina3yearstudy |