Cargando…

End-expiratory Occlusion Test and Mini-fluid Challenge Test for Predicting Fluid Responsiveness in Acute Circulatory Failure

INTRODUCTION: Predicting which patients with acute circulatory failure will respond to the fluid by an increase in cardiac output is a daily challenge. End-expiratory occlusion test (EEOT) and mini-fluid challenge (MFC) can be used for assessing fluid responsiveness in patients with spontaneous brea...

Descripción completa

Detalles Bibliográficos
Autores principales: Selvam, Velmurugan, Shende, Dilip, Anand, Rahul Kumar, Kashyap, Lokesh, Ray, Bikash Ranjan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10661572/
https://www.ncbi.nlm.nih.gov/pubmed/38025504
http://dx.doi.org/10.4103/jets.jets_44_23
_version_ 1785138007263674368
author Selvam, Velmurugan
Shende, Dilip
Anand, Rahul Kumar
Kashyap, Lokesh
Ray, Bikash Ranjan
author_facet Selvam, Velmurugan
Shende, Dilip
Anand, Rahul Kumar
Kashyap, Lokesh
Ray, Bikash Ranjan
author_sort Selvam, Velmurugan
collection PubMed
description INTRODUCTION: Predicting which patients with acute circulatory failure will respond to the fluid by an increase in cardiac output is a daily challenge. End-expiratory occlusion test (EEOT) and mini-fluid challenge (MFC) can be used for assessing fluid responsiveness in patients with spontaneous breathing activity, cardiac arrhythmias, low-tidal volume and/or low lung compliance. METHODS: The objective of the study is to evaluate the value of EEOT and MFC-induced rise in left ventricular outflow tract (LVOT) velocity time integral (VTI) in predicting fluid responsiveness in acute circulatory failure in comparison to the passive leg-raising (PLR) test. Hundred critically ill ventilated and sedated patients with acute circulatory failure were studied. LVOT VTI was measured by transthoracic echocardiography before and after EEOT (interrupting the ventilator at end-expiration over 15 s), and before and after MFC (100 ml of Ringer lactate was infused over 1 min). The variation of LVOT VTI after EEOT and the MFC was calculated from the baseline. Sensitivity, specificity, and area under the receiver-operating characteristic (AUROC) curve of LVOT VTI after EEOT and MFC to predict fluid responsiveness were determined. RESULTS: After PLR, stroke volume (SV) increased by ≥12% in 49 patients, who were defined as responders and 34 patients in whom the increase in SV <12% were defined as nonresponders. A cutoff of 9.1% Change in VTI after MFC (ΔVTI(MFC)) predicted fluid responsiveness with an AUROC of 0.96 (P < 0.001) with sensitivity and specificity of 91.5% and 88.9%, respectively. Change in VTI after EEOT (ΔVTI(EEOT)) >4.3% predicted fluid responsiveness with sensitivity and specificity 89.4% and 88.9%, respectively, with an AUROC of 0.97 (P < 0.001), but in 17 patients, EEOT was not possible because triggering of the ventilator by the patient’s inspiratory effort. CONCLUSION: In conclusion, in mechanically ventilated patients with acute circulatory failure Δ VTI(MFC) and Δ VTI (EEOT) accurately predicts fluid responsiveness.
format Online
Article
Text
id pubmed-10661572
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-106615722023-07-01 End-expiratory Occlusion Test and Mini-fluid Challenge Test for Predicting Fluid Responsiveness in Acute Circulatory Failure Selvam, Velmurugan Shende, Dilip Anand, Rahul Kumar Kashyap, Lokesh Ray, Bikash Ranjan J Emerg Trauma Shock Original Article INTRODUCTION: Predicting which patients with acute circulatory failure will respond to the fluid by an increase in cardiac output is a daily challenge. End-expiratory occlusion test (EEOT) and mini-fluid challenge (MFC) can be used for assessing fluid responsiveness in patients with spontaneous breathing activity, cardiac arrhythmias, low-tidal volume and/or low lung compliance. METHODS: The objective of the study is to evaluate the value of EEOT and MFC-induced rise in left ventricular outflow tract (LVOT) velocity time integral (VTI) in predicting fluid responsiveness in acute circulatory failure in comparison to the passive leg-raising (PLR) test. Hundred critically ill ventilated and sedated patients with acute circulatory failure were studied. LVOT VTI was measured by transthoracic echocardiography before and after EEOT (interrupting the ventilator at end-expiration over 15 s), and before and after MFC (100 ml of Ringer lactate was infused over 1 min). The variation of LVOT VTI after EEOT and the MFC was calculated from the baseline. Sensitivity, specificity, and area under the receiver-operating characteristic (AUROC) curve of LVOT VTI after EEOT and MFC to predict fluid responsiveness were determined. RESULTS: After PLR, stroke volume (SV) increased by ≥12% in 49 patients, who were defined as responders and 34 patients in whom the increase in SV <12% were defined as nonresponders. A cutoff of 9.1% Change in VTI after MFC (ΔVTI(MFC)) predicted fluid responsiveness with an AUROC of 0.96 (P < 0.001) with sensitivity and specificity of 91.5% and 88.9%, respectively. Change in VTI after EEOT (ΔVTI(EEOT)) >4.3% predicted fluid responsiveness with sensitivity and specificity 89.4% and 88.9%, respectively, with an AUROC of 0.97 (P < 0.001), but in 17 patients, EEOT was not possible because triggering of the ventilator by the patient’s inspiratory effort. CONCLUSION: In conclusion, in mechanically ventilated patients with acute circulatory failure Δ VTI(MFC) and Δ VTI (EEOT) accurately predicts fluid responsiveness. Wolters Kluwer - Medknow 2023 2023-08-10 /pmc/articles/PMC10661572/ /pubmed/38025504 http://dx.doi.org/10.4103/jets.jets_44_23 Text en Copyright: © 2023 Journal of Emergencies, Trauma, and Shock https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Selvam, Velmurugan
Shende, Dilip
Anand, Rahul Kumar
Kashyap, Lokesh
Ray, Bikash Ranjan
End-expiratory Occlusion Test and Mini-fluid Challenge Test for Predicting Fluid Responsiveness in Acute Circulatory Failure
title End-expiratory Occlusion Test and Mini-fluid Challenge Test for Predicting Fluid Responsiveness in Acute Circulatory Failure
title_full End-expiratory Occlusion Test and Mini-fluid Challenge Test for Predicting Fluid Responsiveness in Acute Circulatory Failure
title_fullStr End-expiratory Occlusion Test and Mini-fluid Challenge Test for Predicting Fluid Responsiveness in Acute Circulatory Failure
title_full_unstemmed End-expiratory Occlusion Test and Mini-fluid Challenge Test for Predicting Fluid Responsiveness in Acute Circulatory Failure
title_short End-expiratory Occlusion Test and Mini-fluid Challenge Test for Predicting Fluid Responsiveness in Acute Circulatory Failure
title_sort end-expiratory occlusion test and mini-fluid challenge test for predicting fluid responsiveness in acute circulatory failure
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10661572/
https://www.ncbi.nlm.nih.gov/pubmed/38025504
http://dx.doi.org/10.4103/jets.jets_44_23
work_keys_str_mv AT selvamvelmurugan endexpiratoryocclusiontestandminifluidchallengetestforpredictingfluidresponsivenessinacutecirculatoryfailure
AT shendedilip endexpiratoryocclusiontestandminifluidchallengetestforpredictingfluidresponsivenessinacutecirculatoryfailure
AT anandrahulkumar endexpiratoryocclusiontestandminifluidchallengetestforpredictingfluidresponsivenessinacutecirculatoryfailure
AT kashyaplokesh endexpiratoryocclusiontestandminifluidchallengetestforpredictingfluidresponsivenessinacutecirculatoryfailure
AT raybikashranjan endexpiratoryocclusiontestandminifluidchallengetestforpredictingfluidresponsivenessinacutecirculatoryfailure