Cargando…
Surveillance of central line associated bloodstream infection (CLABSI) – comparison of current (CDC/NHSN) and modified criteria: A prospective study
BACKGROUND AND AIMS: There is a huge load of central line–associated bloodstream infection (CLABSI) being reported in developing countries, with increased mortality and healthcare costs. Effective surveillance is a must to reduce the incidence of CLABSI. The current criteria (Centre for Disease Cont...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10661645/ https://www.ncbi.nlm.nih.gov/pubmed/38025573 http://dx.doi.org/10.4103/joacp.joacp_393_21 |
Sumario: | BACKGROUND AND AIMS: There is a huge load of central line–associated bloodstream infection (CLABSI) being reported in developing countries, with increased mortality and healthcare costs. Effective surveillance is a must to reduce the incidence of CLABSI. The current criteria (Centre for Disease Control and Prevention/National Healthcare Safety Network [CDC/NHSN]) for CLABSI surveillance have their own shortcomings. For diagnosing CLABSI, current CDC/NHSN CLABSI surveillance criteria are laborious and time consuming with low predictive power. Hence, modified criteria have been postulated, which are simple and implementable at resource-constrained setups. The primary objective was to compare modified criteria with CDC criteria. The secondary objective was to determine the prevalence of CRBSI. MATERIAL AND METHODS: A total of 98 patients with central line in situ or having the central venous line removed ≤24 hrs prior to the date of the event were enrolled. Paired blood cultures were obtained and results were analyzed using differential time to positivity. RESULTS: The incidence of CLBSI was 8.16% and the device utilization rate was 11.6%. The negative predictive value of both the surveillance criteria was found to be excellent and comparable (96.2% for modified criteria and 97.1% for CDC criteria), therefore both can be used for screening purposes. AUC for current CDC/NHSN criteria was better than modified criteria (0.76 versus 0.66, P < 0.0001), suggesting it to be a better criterion for surveillance of CLABSI. CONCLUSION: Modified criteria were not superior to CDC/NHSN criteria for surveillance. Thus, there is a scope of improving the modified criteria for the purpose of surveillance. CLBSI load was higher; CLABSI bundle for prevention is thus highly recommended. |
---|