Cargando…

Pretreatment patient-specific quality assurance prediction based on 1D complexity metrics and 3D planning dose: classification, gamma passing rates, and DVH metrics

PURPOSE: Highly modulated radiotherapy plans aim to achieve target conformality and spare organs at risk, but the high complexity of the plan may increase the uncertainty of treatment. Thus, patient-specific quality assurance (PSQA) plays a crucial role in ensuring treatment accuracy and providing c...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Liyuan, Luo, Huanli, Li, Shi, Tan, Xia, Feng, Bin, Yang, Xin, Wang, Ying, Jin, Fu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10662260/
https://www.ncbi.nlm.nih.gov/pubmed/37986008
http://dx.doi.org/10.1186/s13014-023-02376-4
_version_ 1785148526978662400
author Chen, Liyuan
Luo, Huanli
Li, Shi
Tan, Xia
Feng, Bin
Yang, Xin
Wang, Ying
Jin, Fu
author_facet Chen, Liyuan
Luo, Huanli
Li, Shi
Tan, Xia
Feng, Bin
Yang, Xin
Wang, Ying
Jin, Fu
author_sort Chen, Liyuan
collection PubMed
description PURPOSE: Highly modulated radiotherapy plans aim to achieve target conformality and spare organs at risk, but the high complexity of the plan may increase the uncertainty of treatment. Thus, patient-specific quality assurance (PSQA) plays a crucial role in ensuring treatment accuracy and providing clinical guidance. This study aims to propose a prediction model based on complexity metrics and patient planning dose for PSQA results. MATERIALS AND METHODS: Planning dose, measurement-based reconstructed dose and plan complexity metrics of the 687 radiotherapy plans of patients treated in our institution were collected for model establishing. Global gamma passing rate (GPR, 3%/2mm,10% threshold) of 90% was used as QA criterion. Neural architecture models based on Swin-transformer were adapted to process 3D dose and incorporate 1D metrics to predict QA results. The dataset was divided into training (447), validation (90), and testing (150) sets. Evaluation of predictions was performed using mean absolute error (MAE) for GPR, planning target volume (PTV) HI and PTV CI, mean absolute percentage error (MAPE) for PTV D(95), PTV D(2) and PTV D(mean), and the area under the receiver operating characteristic (ROC) curve (AUC) for classification. Furthermore, we also compare the prediction results with other models based on either only 1D or 3D inputs. RESULTS: In this dataset, 72.8% (500/687) plans passed the pretreatment QA under the criterion. On the testing set, our model achieves the highest performance, with the 1D model slightly surpassing the 3D model. The performance results are as follows (combine, 1D, and 3D transformer): The AUCs are 0.92, 0.88 and 0.86 for QA classification. The MAEs of prediction are 0.039, 0.046, and 0.040 for 3D GPR, 0.018, 0.021, and 0.019 for PTV HI, and 0.075, 0.078, and 0.084 for PTV CI. Specifically, for cases with 3D GPRs greater than 90%, the MAE could achieve 0.020 (combine). The MAPE of prediction is 1.23%, 1.52%, and 1.66% for PTV D(95), 2.36%, 2.67%, and 2.45% for PTV D(2), and 1.46%, 1.70%, and 1.71% for PTV D(mean). CONCLUSION: The model based on 1D complexity metrics and 3D planning dose could predict pretreatment PSQA results with high accuracy and the complexity metrics play a leading role in the model. Furthermore, dose-volume metric deviations of PTV could be predicted and more clinically valuable information could be provided. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-023-02376-4.
format Online
Article
Text
id pubmed-10662260
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-106622602023-11-20 Pretreatment patient-specific quality assurance prediction based on 1D complexity metrics and 3D planning dose: classification, gamma passing rates, and DVH metrics Chen, Liyuan Luo, Huanli Li, Shi Tan, Xia Feng, Bin Yang, Xin Wang, Ying Jin, Fu Radiat Oncol Research PURPOSE: Highly modulated radiotherapy plans aim to achieve target conformality and spare organs at risk, but the high complexity of the plan may increase the uncertainty of treatment. Thus, patient-specific quality assurance (PSQA) plays a crucial role in ensuring treatment accuracy and providing clinical guidance. This study aims to propose a prediction model based on complexity metrics and patient planning dose for PSQA results. MATERIALS AND METHODS: Planning dose, measurement-based reconstructed dose and plan complexity metrics of the 687 radiotherapy plans of patients treated in our institution were collected for model establishing. Global gamma passing rate (GPR, 3%/2mm,10% threshold) of 90% was used as QA criterion. Neural architecture models based on Swin-transformer were adapted to process 3D dose and incorporate 1D metrics to predict QA results. The dataset was divided into training (447), validation (90), and testing (150) sets. Evaluation of predictions was performed using mean absolute error (MAE) for GPR, planning target volume (PTV) HI and PTV CI, mean absolute percentage error (MAPE) for PTV D(95), PTV D(2) and PTV D(mean), and the area under the receiver operating characteristic (ROC) curve (AUC) for classification. Furthermore, we also compare the prediction results with other models based on either only 1D or 3D inputs. RESULTS: In this dataset, 72.8% (500/687) plans passed the pretreatment QA under the criterion. On the testing set, our model achieves the highest performance, with the 1D model slightly surpassing the 3D model. The performance results are as follows (combine, 1D, and 3D transformer): The AUCs are 0.92, 0.88 and 0.86 for QA classification. The MAEs of prediction are 0.039, 0.046, and 0.040 for 3D GPR, 0.018, 0.021, and 0.019 for PTV HI, and 0.075, 0.078, and 0.084 for PTV CI. Specifically, for cases with 3D GPRs greater than 90%, the MAE could achieve 0.020 (combine). The MAPE of prediction is 1.23%, 1.52%, and 1.66% for PTV D(95), 2.36%, 2.67%, and 2.45% for PTV D(2), and 1.46%, 1.70%, and 1.71% for PTV D(mean). CONCLUSION: The model based on 1D complexity metrics and 3D planning dose could predict pretreatment PSQA results with high accuracy and the complexity metrics play a leading role in the model. Furthermore, dose-volume metric deviations of PTV could be predicted and more clinically valuable information could be provided. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-023-02376-4. BioMed Central 2023-11-20 /pmc/articles/PMC10662260/ /pubmed/37986008 http://dx.doi.org/10.1186/s13014-023-02376-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Chen, Liyuan
Luo, Huanli
Li, Shi
Tan, Xia
Feng, Bin
Yang, Xin
Wang, Ying
Jin, Fu
Pretreatment patient-specific quality assurance prediction based on 1D complexity metrics and 3D planning dose: classification, gamma passing rates, and DVH metrics
title Pretreatment patient-specific quality assurance prediction based on 1D complexity metrics and 3D planning dose: classification, gamma passing rates, and DVH metrics
title_full Pretreatment patient-specific quality assurance prediction based on 1D complexity metrics and 3D planning dose: classification, gamma passing rates, and DVH metrics
title_fullStr Pretreatment patient-specific quality assurance prediction based on 1D complexity metrics and 3D planning dose: classification, gamma passing rates, and DVH metrics
title_full_unstemmed Pretreatment patient-specific quality assurance prediction based on 1D complexity metrics and 3D planning dose: classification, gamma passing rates, and DVH metrics
title_short Pretreatment patient-specific quality assurance prediction based on 1D complexity metrics and 3D planning dose: classification, gamma passing rates, and DVH metrics
title_sort pretreatment patient-specific quality assurance prediction based on 1d complexity metrics and 3d planning dose: classification, gamma passing rates, and dvh metrics
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10662260/
https://www.ncbi.nlm.nih.gov/pubmed/37986008
http://dx.doi.org/10.1186/s13014-023-02376-4
work_keys_str_mv AT chenliyuan pretreatmentpatientspecificqualityassurancepredictionbasedon1dcomplexitymetricsand3dplanningdoseclassificationgammapassingratesanddvhmetrics
AT luohuanli pretreatmentpatientspecificqualityassurancepredictionbasedon1dcomplexitymetricsand3dplanningdoseclassificationgammapassingratesanddvhmetrics
AT lishi pretreatmentpatientspecificqualityassurancepredictionbasedon1dcomplexitymetricsand3dplanningdoseclassificationgammapassingratesanddvhmetrics
AT tanxia pretreatmentpatientspecificqualityassurancepredictionbasedon1dcomplexitymetricsand3dplanningdoseclassificationgammapassingratesanddvhmetrics
AT fengbin pretreatmentpatientspecificqualityassurancepredictionbasedon1dcomplexitymetricsand3dplanningdoseclassificationgammapassingratesanddvhmetrics
AT yangxin pretreatmentpatientspecificqualityassurancepredictionbasedon1dcomplexitymetricsand3dplanningdoseclassificationgammapassingratesanddvhmetrics
AT wangying pretreatmentpatientspecificqualityassurancepredictionbasedon1dcomplexitymetricsand3dplanningdoseclassificationgammapassingratesanddvhmetrics
AT jinfu pretreatmentpatientspecificqualityassurancepredictionbasedon1dcomplexitymetricsand3dplanningdoseclassificationgammapassingratesanddvhmetrics