Cargando…
Submuscular plating vs. elastic stable intramedullary nailing for diaphyseal femur fractures in children: a systematic review and meta-analysis
OBJECTIVES: This review evaluates the safety and efficacy of submuscular plating (SMP) vs. elastic stable intramedullary nailing (ESIN) in the treatment of pediatric femur shaft fracture. METHOD: Studies comparing the efficacy and safety of SMP and ESIN in pediatric shaft fracture were retrieved fro...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10663353/ https://www.ncbi.nlm.nih.gov/pubmed/38027269 http://dx.doi.org/10.3389/fped.2023.1256630 |
_version_ | 1785138381581189120 |
---|---|
author | Li, Donghui Wang, Xiangyue Lu, Jialing Xue, Mingfeng |
author_facet | Li, Donghui Wang, Xiangyue Lu, Jialing Xue, Mingfeng |
author_sort | Li, Donghui |
collection | PubMed |
description | OBJECTIVES: This review evaluates the safety and efficacy of submuscular plating (SMP) vs. elastic stable intramedullary nailing (ESIN) in the treatment of pediatric femur shaft fracture. METHOD: Studies comparing the efficacy and safety of SMP and ESIN in pediatric shaft fracture were retrieved from five databases (PubMed, Embase, Cochrane, OVID, and Web of Science) from inception to March 2023 using a systematic literature search strategy. A total of 13 outcome measures, such as perioperative parameters, clinical outcomes, and radiographic results, were included in the meta-analysis. RESULTS: Eight eligible studies involving 491 patients were included in the narrative synthesis. There were no significant differences in baseline characteristics between the two groups. Meta-analysis showed reduced radiation time (RT), soft tissue irritation and angular deformation in the SMP group than in the ESIN group. However, the SMP group had greater estimated blood loss (EBL) than the ESIN group. The duration of surgery, length of hospital stay (LOS), implant removal, complications requiring surgery, Flynn score, incidence of infection, fracture healing time, and limb length discrepancy (LLD) were similar between the two groups. Only one study reported higher incidences of fracture nonunion or delayed healing in the ESIN group. CONCLUSION: SMP is an effective and safe intervention superior to ESIN in reducing soft tissue irritation, angular deformation and radiation time. Given the presence of potential bias and heterogeneity, surgeons should select the treatment that would provide the best outcomes for EBL, LOS, operation time, and bone nonunion or delayed healing based on their experience. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023404118, Identifier PROSPERO (CRD42021228512). |
format | Online Article Text |
id | pubmed-10663353 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-106633532023-11-08 Submuscular plating vs. elastic stable intramedullary nailing for diaphyseal femur fractures in children: a systematic review and meta-analysis Li, Donghui Wang, Xiangyue Lu, Jialing Xue, Mingfeng Front Pediatr Pediatrics OBJECTIVES: This review evaluates the safety and efficacy of submuscular plating (SMP) vs. elastic stable intramedullary nailing (ESIN) in the treatment of pediatric femur shaft fracture. METHOD: Studies comparing the efficacy and safety of SMP and ESIN in pediatric shaft fracture were retrieved from five databases (PubMed, Embase, Cochrane, OVID, and Web of Science) from inception to March 2023 using a systematic literature search strategy. A total of 13 outcome measures, such as perioperative parameters, clinical outcomes, and radiographic results, were included in the meta-analysis. RESULTS: Eight eligible studies involving 491 patients were included in the narrative synthesis. There were no significant differences in baseline characteristics between the two groups. Meta-analysis showed reduced radiation time (RT), soft tissue irritation and angular deformation in the SMP group than in the ESIN group. However, the SMP group had greater estimated blood loss (EBL) than the ESIN group. The duration of surgery, length of hospital stay (LOS), implant removal, complications requiring surgery, Flynn score, incidence of infection, fracture healing time, and limb length discrepancy (LLD) were similar between the two groups. Only one study reported higher incidences of fracture nonunion or delayed healing in the ESIN group. CONCLUSION: SMP is an effective and safe intervention superior to ESIN in reducing soft tissue irritation, angular deformation and radiation time. Given the presence of potential bias and heterogeneity, surgeons should select the treatment that would provide the best outcomes for EBL, LOS, operation time, and bone nonunion or delayed healing based on their experience. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023404118, Identifier PROSPERO (CRD42021228512). Frontiers Media S.A. 2023-11-08 /pmc/articles/PMC10663353/ /pubmed/38027269 http://dx.doi.org/10.3389/fped.2023.1256630 Text en © 2023 Li, Wang, Lu and Xue. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Pediatrics Li, Donghui Wang, Xiangyue Lu, Jialing Xue, Mingfeng Submuscular plating vs. elastic stable intramedullary nailing for diaphyseal femur fractures in children: a systematic review and meta-analysis |
title | Submuscular plating vs. elastic stable intramedullary nailing for diaphyseal femur fractures in children: a systematic review and meta-analysis |
title_full | Submuscular plating vs. elastic stable intramedullary nailing for diaphyseal femur fractures in children: a systematic review and meta-analysis |
title_fullStr | Submuscular plating vs. elastic stable intramedullary nailing for diaphyseal femur fractures in children: a systematic review and meta-analysis |
title_full_unstemmed | Submuscular plating vs. elastic stable intramedullary nailing for diaphyseal femur fractures in children: a systematic review and meta-analysis |
title_short | Submuscular plating vs. elastic stable intramedullary nailing for diaphyseal femur fractures in children: a systematic review and meta-analysis |
title_sort | submuscular plating vs. elastic stable intramedullary nailing for diaphyseal femur fractures in children: a systematic review and meta-analysis |
topic | Pediatrics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10663353/ https://www.ncbi.nlm.nih.gov/pubmed/38027269 http://dx.doi.org/10.3389/fped.2023.1256630 |
work_keys_str_mv | AT lidonghui submuscularplatingvselasticstableintramedullarynailingfordiaphysealfemurfracturesinchildrenasystematicreviewandmetaanalysis AT wangxiangyue submuscularplatingvselasticstableintramedullarynailingfordiaphysealfemurfracturesinchildrenasystematicreviewandmetaanalysis AT lujialing submuscularplatingvselasticstableintramedullarynailingfordiaphysealfemurfracturesinchildrenasystematicreviewandmetaanalysis AT xuemingfeng submuscularplatingvselasticstableintramedullarynailingfordiaphysealfemurfracturesinchildrenasystematicreviewandmetaanalysis |