An Unusual Case of Onlay Reverse Shoulder Arthroplasty Disassembly Due to Cement Interposition. A Case Report
INTRODUCTION: Reverse shoulder arthroplasty (RSA) complication rates range between 1.4% and 28% depending on the nature of the indication. Even though glenosphere dissociation is the third most frequent complication after RSA, with an incidence that can rise to just over 12%, there is no evidence in...
Autores principales: | Brandariz, Rodrigo, Lüdke, Eric, Laurencet, Pierre-Alexandre, Cunningham, Gregory |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10664207/ https://www.ncbi.nlm.nih.gov/pubmed/38025360 http://dx.doi.org/10.13107/jocr.2023.v13.i11.4012 |
Ejemplares similares
-
Onlay versus Inlay humeral steam in Reverse Shoulder Arthroplasty (RSA): clinical and biomechanical study
por: Beltrame, Alessandro, et al.
Publicado: (2019) -
Comparison of Clinical Performance of Inlay versus Onlay Humerus Implants in Reverse Total Shoulder Arthroplasty
por: Lee, Hyo-Jin, et al.
Publicado: (2023) -
PHILOS plating of periprosthetic humeral shaft fracture after onlay-type reverse total shoulder arthroplasty: a case report
por: Saito, Tomohiro, et al.
Publicado: (2020) -
Reverse shoulder arthroplasty using an onlay humeral prosthesis, offset humeral tray, and augmented glenoid baseplate: surgical technique and review of the impact of prosthesis design on scapular fractures following reverse shoulder arthroplasty
por: Holliday, Charles, et al.
Publicado: (2022) -
Onlay Uncemented Lateralized Reverse Shoulder Arthroplasty for Fracture Sequelae Type 1 with Valgus/Varus Malunion: Deltoid Lengthening and Outcomes
por: Romano, Alfonso Maria, et al.
Publicado: (2020)