Experience of treating congenital complete atrioventricular block with epicardial pacemaker in infants and young children: a retrospective study

BACKGROUND: This article summarizes the treatment experience for congenital complete atrioventricular block (CCAVB) in newborns and infants, and discusses the necessity and feasibility of treating CCAVB with permanent pacemaker implantation in this population. METHODS: In this study, the clinical da...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Linhong, Meng, Qiang, Liu, Changgen, Wang, Gang, Wang, Hui, Zhou, Gengxu, Feng, Zhichun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10664347/
https://www.ncbi.nlm.nih.gov/pubmed/37990158
http://dx.doi.org/10.1186/s12872-023-03620-1
Descripción
Sumario:BACKGROUND: This article summarizes the treatment experience for congenital complete atrioventricular block (CCAVB) in newborns and infants, and discusses the necessity and feasibility of treating CCAVB with permanent pacemaker implantation in this population. METHODS: In this study, the clinical data and follow-up results of nine children admitted at our center with CCAVB from January 2005 to March 2023 were retrospectively analyzed. Among them, two children received early implantation of permanent pacemakers (within 1 year of age), two children received non-early implantation (1 year or older), and the remaining five children received no pacemaker implantation. CCAVB diagnosis was confirmed by clinical symptoms and clinical examinations, including electrocardiography and echocardiography before surgery. After surgery, the pacing and sensing functions of the pacemaker were observed using electrocardiography, echocardiography, and pacing threshold monitoring. A comprehensive assessment of the treatment efficacy was conducted, encompassing improvements in clinical symptoms, growth and development, as well as the absence of any additional potential complications. The children who did not receive pacemaker implantation were followed up. RESULTS: Among the four children who successfully received pacemaker implantation, one child who received non-early implantation died. For the remaining three children, the threshold level, amplitude, impedance, and minute ventilation sensor function of the pacemaker were good during the follow-up period, with a heart rate at the pacing rate. The growth and development of the aforementioned patients who received pacemaker implantation demonstrated adherence to the percentile curve, and their motor and cognitive development remained unaffected. However, among the children who did not undergo pacemaker implantation, two experienced death, while three were lost to follow-up, thereby limiting the evaluation of their long-term outcomes. CONCLUSIONS: Early implantation of an epicardial pacemaker at an early stage in newborns and infants diagnosed with CCAVB can significantly improve clinical symptoms without affecting their growth and development. These data are in line with current literature and suggest that early implantation of an epicardial pacemaker in newborns and infants diagnosed with CCAVB but further studies are needed.