Cargando…
Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review
AIMS: Pulmonary vein isolation (PVI) plays a central role in the interventional treatment of atrial fibrillation (AF). Uncertainties remain about the durability of ablation lesions from different energy sources. We aimed to systematically review the durability of ablation lesions associated with var...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10664405/ https://www.ncbi.nlm.nih.gov/pubmed/37944133 http://dx.doi.org/10.1093/europace/euad335 |
_version_ | 1785138609650663424 |
---|---|
author | Serban, Teodor Mannhart, Diego Abid, Qurrat-ul-ain Höchli, Andres Lazar, Sorin Krisai, Philipp Bettelini, Arianna Sofia Knecht, Sven Kühne, Michael Sticherling, Christian du Fay de Lavallaz, Jeanne Badertscher, Patrick |
author_facet | Serban, Teodor Mannhart, Diego Abid, Qurrat-ul-ain Höchli, Andres Lazar, Sorin Krisai, Philipp Bettelini, Arianna Sofia Knecht, Sven Kühne, Michael Sticherling, Christian du Fay de Lavallaz, Jeanne Badertscher, Patrick |
author_sort | Serban, Teodor |
collection | PubMed |
description | AIMS: Pulmonary vein isolation (PVI) plays a central role in the interventional treatment of atrial fibrillation (AF). Uncertainties remain about the durability of ablation lesions from different energy sources. We aimed to systematically review the durability of ablation lesions associated with various PVI-techniques using different energy sources for the treatment of AF. METHODS AND RESULTS: Structured systematic database search for articles published between January 2010 and January 2023 reporting PVI-lesion durability as evaluated in the overall cohort through repeat invasive remapping during follow-up. Studies evaluating only a proportion of the initial cohort in redo procedures were excluded. A total of 19 studies investigating 1050 patients (mean age 60 years, 31% women, time to remap 2–7 months) were included. In a pooled analysis, 99.7% of the PVs and 99.4% of patients were successfully ablated at baseline and 75.5% of the PVs remained isolated and 51% of the patients had all PVs persistently isolated at follow-up across all energy sources. In a pooled analysis of the percentages of PVs durably isolated during follow-up, the estimates of RFA were the lowest of all energy sources at 71% (95% CI 69–73, 11 studies), but comparable with cryoballoon (79%, 95%CI 74–83, 3 studies). Higher durability percentages were reported in PVs ablated with laser-balloon (84%, 95%CI 78–89, one study) and PFA (87%, 95%CI 84–90, 2 studies). CONCLUSION: We observed no significant difference in the durability of the ablation lesions of the four evaluated energies after adjusting for procedural and baseline populational characteristics. |
format | Online Article Text |
id | pubmed-10664405 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-106644052023-11-07 Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review Serban, Teodor Mannhart, Diego Abid, Qurrat-ul-ain Höchli, Andres Lazar, Sorin Krisai, Philipp Bettelini, Arianna Sofia Knecht, Sven Kühne, Michael Sticherling, Christian du Fay de Lavallaz, Jeanne Badertscher, Patrick Europace Meta-Analysis AIMS: Pulmonary vein isolation (PVI) plays a central role in the interventional treatment of atrial fibrillation (AF). Uncertainties remain about the durability of ablation lesions from different energy sources. We aimed to systematically review the durability of ablation lesions associated with various PVI-techniques using different energy sources for the treatment of AF. METHODS AND RESULTS: Structured systematic database search for articles published between January 2010 and January 2023 reporting PVI-lesion durability as evaluated in the overall cohort through repeat invasive remapping during follow-up. Studies evaluating only a proportion of the initial cohort in redo procedures were excluded. A total of 19 studies investigating 1050 patients (mean age 60 years, 31% women, time to remap 2–7 months) were included. In a pooled analysis, 99.7% of the PVs and 99.4% of patients were successfully ablated at baseline and 75.5% of the PVs remained isolated and 51% of the patients had all PVs persistently isolated at follow-up across all energy sources. In a pooled analysis of the percentages of PVs durably isolated during follow-up, the estimates of RFA were the lowest of all energy sources at 71% (95% CI 69–73, 11 studies), but comparable with cryoballoon (79%, 95%CI 74–83, 3 studies). Higher durability percentages were reported in PVs ablated with laser-balloon (84%, 95%CI 78–89, one study) and PFA (87%, 95%CI 84–90, 2 studies). CONCLUSION: We observed no significant difference in the durability of the ablation lesions of the four evaluated energies after adjusting for procedural and baseline populational characteristics. Oxford University Press 2023-11-07 /pmc/articles/PMC10664405/ /pubmed/37944133 http://dx.doi.org/10.1093/europace/euad335 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Meta-Analysis Serban, Teodor Mannhart, Diego Abid, Qurrat-ul-ain Höchli, Andres Lazar, Sorin Krisai, Philipp Bettelini, Arianna Sofia Knecht, Sven Kühne, Michael Sticherling, Christian du Fay de Lavallaz, Jeanne Badertscher, Patrick Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review |
title | Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review |
title_full | Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review |
title_fullStr | Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review |
title_full_unstemmed | Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review |
title_short | Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review |
title_sort | durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review |
topic | Meta-Analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10664405/ https://www.ncbi.nlm.nih.gov/pubmed/37944133 http://dx.doi.org/10.1093/europace/euad335 |
work_keys_str_mv | AT serbanteodor durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT mannhartdiego durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT abidqurratulain durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT hochliandres durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT lazarsorin durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT krisaiphilipp durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT betteliniariannasofia durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT knechtsven durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT kuhnemichael durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT sticherlingchristian durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT dufaydelavallazjeanne durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview AT badertscherpatrick durabilityofpulmonaryveinisolationforatrialfibrillationametaanalysisandsystematicreview |