Cargando…

Analytical Validation of MINI-PET as Point-of-Care for Erythrocyte Sedimentation Rate Measure in Horses

The erythrocyte sedimentation rate (ESR) is a widely used diagnostic assay in human medicine but nowadays poorly applied in veterinary medicine. This test measures the speed (millimeters per hour) at which red blood cells settle in a whole anticoagulated blood tube. In human medicine, high ESR value...

Descripción completa

Detalles Bibliográficos
Autores principales: Pieroni, Carolina, Grassi, Andrea, Pantoli, Marianna, Berretti, Mirko, Messina, Stefano, Giovannini, Chiara, Lubas, George, Diamanti, Daniela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10665103/
https://www.ncbi.nlm.nih.gov/pubmed/38023429
http://dx.doi.org/10.1155/2023/9965095
_version_ 1785148833261420544
author Pieroni, Carolina
Grassi, Andrea
Pantoli, Marianna
Berretti, Mirko
Messina, Stefano
Giovannini, Chiara
Lubas, George
Diamanti, Daniela
author_facet Pieroni, Carolina
Grassi, Andrea
Pantoli, Marianna
Berretti, Mirko
Messina, Stefano
Giovannini, Chiara
Lubas, George
Diamanti, Daniela
author_sort Pieroni, Carolina
collection PubMed
description The erythrocyte sedimentation rate (ESR) is a widely used diagnostic assay in human medicine but nowadays poorly applied in veterinary medicine. This test measures the speed (millimeters per hour) at which red blood cells settle in a whole anticoagulated blood tube. In human medicine, high ESR values are associated with various disorders, including infections, rheumatoid arthritis, oncologic diseases, and other inflammatory conditions. The ESR can also be influenced by some factors such as age and gender. In veterinary medicine, the ESR with the Westergren manual method was almost forgotten over the years due to blood consumption and long turn-around time. The instrument MINI-PET, using a modified Westergren method, does not require blood consumption or release waste product and recently has been applied in canine medicine. The aims of the study in the horse were as follows: to establish the appropriate time to read the ESR with the Westergren reference method; to compare the MINI-PET ESR results with the reference technique; to assess the ESR reference intervals with MINI-PET; and to establish the ESR stability from collection at different time points by MINI-PET. Using 150 horses, we established 60 minutes as the appropriate time for ESR reading with the Westergren method. Moreover, ESR results obtained in 8 minutes with MINI-PET showed a good correlation with the Westergren ESR. Reference intervals (RIs) with MINI-PET were established in mm/h for the healthy horses (geldings 18.6–100.1; stallions, 13.8–55.7; and mares 1–73.7) according to the American Society of Veterinary Clinical Pathology guidelines. In addition, the ESR stability from the blood collection time was evaluated in the MINI-PET on 15 horses: at room temperature, ESR is stable up to 8 hours and at 4°C up to 24 hours. In conclusion, MINI-PET represents a rapid and reliable tool for measuring ESR in horses, offering a valid option to replace the traditional manual technique.
format Online
Article
Text
id pubmed-10665103
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-106651032023-11-15 Analytical Validation of MINI-PET as Point-of-Care for Erythrocyte Sedimentation Rate Measure in Horses Pieroni, Carolina Grassi, Andrea Pantoli, Marianna Berretti, Mirko Messina, Stefano Giovannini, Chiara Lubas, George Diamanti, Daniela Vet Med Int Research Article The erythrocyte sedimentation rate (ESR) is a widely used diagnostic assay in human medicine but nowadays poorly applied in veterinary medicine. This test measures the speed (millimeters per hour) at which red blood cells settle in a whole anticoagulated blood tube. In human medicine, high ESR values are associated with various disorders, including infections, rheumatoid arthritis, oncologic diseases, and other inflammatory conditions. The ESR can also be influenced by some factors such as age and gender. In veterinary medicine, the ESR with the Westergren manual method was almost forgotten over the years due to blood consumption and long turn-around time. The instrument MINI-PET, using a modified Westergren method, does not require blood consumption or release waste product and recently has been applied in canine medicine. The aims of the study in the horse were as follows: to establish the appropriate time to read the ESR with the Westergren reference method; to compare the MINI-PET ESR results with the reference technique; to assess the ESR reference intervals with MINI-PET; and to establish the ESR stability from collection at different time points by MINI-PET. Using 150 horses, we established 60 minutes as the appropriate time for ESR reading with the Westergren method. Moreover, ESR results obtained in 8 minutes with MINI-PET showed a good correlation with the Westergren ESR. Reference intervals (RIs) with MINI-PET were established in mm/h for the healthy horses (geldings 18.6–100.1; stallions, 13.8–55.7; and mares 1–73.7) according to the American Society of Veterinary Clinical Pathology guidelines. In addition, the ESR stability from the blood collection time was evaluated in the MINI-PET on 15 horses: at room temperature, ESR is stable up to 8 hours and at 4°C up to 24 hours. In conclusion, MINI-PET represents a rapid and reliable tool for measuring ESR in horses, offering a valid option to replace the traditional manual technique. Hindawi 2023-11-15 /pmc/articles/PMC10665103/ /pubmed/38023429 http://dx.doi.org/10.1155/2023/9965095 Text en Copyright © 2023 Carolina Pieroni et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Pieroni, Carolina
Grassi, Andrea
Pantoli, Marianna
Berretti, Mirko
Messina, Stefano
Giovannini, Chiara
Lubas, George
Diamanti, Daniela
Analytical Validation of MINI-PET as Point-of-Care for Erythrocyte Sedimentation Rate Measure in Horses
title Analytical Validation of MINI-PET as Point-of-Care for Erythrocyte Sedimentation Rate Measure in Horses
title_full Analytical Validation of MINI-PET as Point-of-Care for Erythrocyte Sedimentation Rate Measure in Horses
title_fullStr Analytical Validation of MINI-PET as Point-of-Care for Erythrocyte Sedimentation Rate Measure in Horses
title_full_unstemmed Analytical Validation of MINI-PET as Point-of-Care for Erythrocyte Sedimentation Rate Measure in Horses
title_short Analytical Validation of MINI-PET as Point-of-Care for Erythrocyte Sedimentation Rate Measure in Horses
title_sort analytical validation of mini-pet as point-of-care for erythrocyte sedimentation rate measure in horses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10665103/
https://www.ncbi.nlm.nih.gov/pubmed/38023429
http://dx.doi.org/10.1155/2023/9965095
work_keys_str_mv AT pieronicarolina analyticalvalidationofminipetaspointofcareforerythrocytesedimentationratemeasureinhorses
AT grassiandrea analyticalvalidationofminipetaspointofcareforerythrocytesedimentationratemeasureinhorses
AT pantolimarianna analyticalvalidationofminipetaspointofcareforerythrocytesedimentationratemeasureinhorses
AT berrettimirko analyticalvalidationofminipetaspointofcareforerythrocytesedimentationratemeasureinhorses
AT messinastefano analyticalvalidationofminipetaspointofcareforerythrocytesedimentationratemeasureinhorses
AT giovanninichiara analyticalvalidationofminipetaspointofcareforerythrocytesedimentationratemeasureinhorses
AT lubasgeorge analyticalvalidationofminipetaspointofcareforerythrocytesedimentationratemeasureinhorses
AT diamantidaniela analyticalvalidationofminipetaspointofcareforerythrocytesedimentationratemeasureinhorses