Reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics—observations from a simulation-based study
The evidence base of surgical fracture care is extremely sparse with only few sound RCTs available. It is hypothesized that anthropometric factors relevantly influence mechanical conditions in the fracture gap, thereby interfering with the mechanoinduction of fracture healing. Development of a finit...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10665421/ https://www.ncbi.nlm.nih.gov/pubmed/37993727 http://dx.doi.org/10.1038/s41598-023-47910-2 |
_version_ | 1785148866954264576 |
---|---|
author | Roland, Michael Diebels, Stefan Orth, Marcel Pohlemann, Tim Bouillon, Bertil Tjardes, Thorsten |
author_facet | Roland, Michael Diebels, Stefan Orth, Marcel Pohlemann, Tim Bouillon, Bertil Tjardes, Thorsten |
author_sort | Roland, Michael |
collection | PubMed |
description | The evidence base of surgical fracture care is extremely sparse with only few sound RCTs available. It is hypothesized that anthropometric factors relevantly influence mechanical conditions in the fracture gap, thereby interfering with the mechanoinduction of fracture healing. Development of a finite element model of a tibia fracture, which is the basis of an in silico population (n = 300) by systematic variation of anthropometric parameters. Simulations of the stance phase and correlation between anthropometric parameters and the mechanical stimulus in the fracture gap. Analysis of the influence of anthropometric parameters on statistical dispersion between in silico trial cohorts with respect to the probability to generate two, with respect to anthropometric parameters statistically different trial cohorts, given the same power assumptions. The mechanical impact in the fracture gap correlates with anthropometric parameters; confirming the hypothesis that anthropometric factors are a relevant entity. On a cohort level simulation of a fracture trial showed that given an adequate power the principle of randomization successfully levels out the impact of anthropometric factors. From a clinical perspective these group sizes are difficult to achieve, especially when considering that the trials takes advantage of a „laboratory approach “, i.e. the fracture type has not been varied, such that in real world trials the cohort size have to be even larger to level out the different configurations of fractures gaps. Anthropometric parameters have a significant impact on the fracture gap mechanics. The cohort sizes necessary to level out this effect are difficult or unrealistic to achieve in RCTs, which is the reason for sparse evidence in orthotrauma. New approaches to clinical trials taking advantage of modelling and simulation techniques need to be developed and explored. |
format | Online Article Text |
id | pubmed-10665421 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-106654212023-11-22 Reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics—observations from a simulation-based study Roland, Michael Diebels, Stefan Orth, Marcel Pohlemann, Tim Bouillon, Bertil Tjardes, Thorsten Sci Rep Article The evidence base of surgical fracture care is extremely sparse with only few sound RCTs available. It is hypothesized that anthropometric factors relevantly influence mechanical conditions in the fracture gap, thereby interfering with the mechanoinduction of fracture healing. Development of a finite element model of a tibia fracture, which is the basis of an in silico population (n = 300) by systematic variation of anthropometric parameters. Simulations of the stance phase and correlation between anthropometric parameters and the mechanical stimulus in the fracture gap. Analysis of the influence of anthropometric parameters on statistical dispersion between in silico trial cohorts with respect to the probability to generate two, with respect to anthropometric parameters statistically different trial cohorts, given the same power assumptions. The mechanical impact in the fracture gap correlates with anthropometric parameters; confirming the hypothesis that anthropometric factors are a relevant entity. On a cohort level simulation of a fracture trial showed that given an adequate power the principle of randomization successfully levels out the impact of anthropometric factors. From a clinical perspective these group sizes are difficult to achieve, especially when considering that the trials takes advantage of a „laboratory approach “, i.e. the fracture type has not been varied, such that in real world trials the cohort size have to be even larger to level out the different configurations of fractures gaps. Anthropometric parameters have a significant impact on the fracture gap mechanics. The cohort sizes necessary to level out this effect are difficult or unrealistic to achieve in RCTs, which is the reason for sparse evidence in orthotrauma. New approaches to clinical trials taking advantage of modelling and simulation techniques need to be developed and explored. Nature Publishing Group UK 2023-11-22 /pmc/articles/PMC10665421/ /pubmed/37993727 http://dx.doi.org/10.1038/s41598-023-47910-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Roland, Michael Diebels, Stefan Orth, Marcel Pohlemann, Tim Bouillon, Bertil Tjardes, Thorsten Reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics—observations from a simulation-based study |
title | Reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics—observations from a simulation-based study |
title_full | Reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics—observations from a simulation-based study |
title_fullStr | Reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics—observations from a simulation-based study |
title_full_unstemmed | Reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics—observations from a simulation-based study |
title_short | Reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics—observations from a simulation-based study |
title_sort | reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics—observations from a simulation-based study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10665421/ https://www.ncbi.nlm.nih.gov/pubmed/37993727 http://dx.doi.org/10.1038/s41598-023-47910-2 |
work_keys_str_mv | AT rolandmichael reappraisalofclinicaltraumatrialsthecriticalimpactofanthropometricparametersonfracturegapmicromechanicsobservationsfromasimulationbasedstudy AT diebelsstefan reappraisalofclinicaltraumatrialsthecriticalimpactofanthropometricparametersonfracturegapmicromechanicsobservationsfromasimulationbasedstudy AT orthmarcel reappraisalofclinicaltraumatrialsthecriticalimpactofanthropometricparametersonfracturegapmicromechanicsobservationsfromasimulationbasedstudy AT pohlemanntim reappraisalofclinicaltraumatrialsthecriticalimpactofanthropometricparametersonfracturegapmicromechanicsobservationsfromasimulationbasedstudy AT bouillonbertil reappraisalofclinicaltraumatrialsthecriticalimpactofanthropometricparametersonfracturegapmicromechanicsobservationsfromasimulationbasedstudy AT tjardesthorsten reappraisalofclinicaltraumatrialsthecriticalimpactofanthropometricparametersonfracturegapmicromechanicsobservationsfromasimulationbasedstudy |