Cargando…

Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique

The STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique has shown promising results for treating type B aortic dissections, but the potential exists for fatal adverse effects. We present a case of infrarenal aortic rupture while using...

Descripción completa

Detalles Bibliográficos
Autores principales: Hsu, Ashley C., DiBartolomeo, Alexander D., Han, Sukgu M., Fleischman, Fernando, Magee, Gregory A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10665655/
https://www.ncbi.nlm.nih.gov/pubmed/38023324
http://dx.doi.org/10.1016/j.jvscit.2023.101338
_version_ 1785138873410519040
author Hsu, Ashley C.
DiBartolomeo, Alexander D.
Han, Sukgu M.
Fleischman, Fernando
Magee, Gregory A.
author_facet Hsu, Ashley C.
DiBartolomeo, Alexander D.
Han, Sukgu M.
Fleischman, Fernando
Magee, Gregory A.
author_sort Hsu, Ashley C.
collection PubMed
description The STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique has shown promising results for treating type B aortic dissections, but the potential exists for fatal adverse effects. We present a case of infrarenal aortic rupture while using a compliant balloon to balloon mold the true lumen inside previously placed bare metal stents during the STABILISE technique. Caution is advised for providers who wish to perform the STABILISE technique, and we recommend using a semi-compliant balloon sized to the smallest total aortic diameter to mitigate the risk of rupture.
format Online
Article
Text
id pubmed-10665655
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106656552023-09-29 Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique Hsu, Ashley C. DiBartolomeo, Alexander D. Han, Sukgu M. Fleischman, Fernando Magee, Gregory A. J Vasc Surg Cases Innov Tech Case report The STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique has shown promising results for treating type B aortic dissections, but the potential exists for fatal adverse effects. We present a case of infrarenal aortic rupture while using a compliant balloon to balloon mold the true lumen inside previously placed bare metal stents during the STABILISE technique. Caution is advised for providers who wish to perform the STABILISE technique, and we recommend using a semi-compliant balloon sized to the smallest total aortic diameter to mitigate the risk of rupture. Elsevier 2023-09-29 /pmc/articles/PMC10665655/ /pubmed/38023324 http://dx.doi.org/10.1016/j.jvscit.2023.101338 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case report
Hsu, Ashley C.
DiBartolomeo, Alexander D.
Han, Sukgu M.
Fleischman, Fernando
Magee, Gregory A.
Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique
title Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique
title_full Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique
title_fullStr Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique
title_full_unstemmed Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique
title_short Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique
title_sort aortic rupture during stabilise (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10665655/
https://www.ncbi.nlm.nih.gov/pubmed/38023324
http://dx.doi.org/10.1016/j.jvscit.2023.101338
work_keys_str_mv AT hsuashleyc aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique
AT dibartolomeoalexanderd aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique
AT hansukgum aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique
AT fleischmanfernando aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique
AT mageegregorya aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique