Cargando…
Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique
The STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique has shown promising results for treating type B aortic dissections, but the potential exists for fatal adverse effects. We present a case of infrarenal aortic rupture while using...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10665655/ https://www.ncbi.nlm.nih.gov/pubmed/38023324 http://dx.doi.org/10.1016/j.jvscit.2023.101338 |
_version_ | 1785138873410519040 |
---|---|
author | Hsu, Ashley C. DiBartolomeo, Alexander D. Han, Sukgu M. Fleischman, Fernando Magee, Gregory A. |
author_facet | Hsu, Ashley C. DiBartolomeo, Alexander D. Han, Sukgu M. Fleischman, Fernando Magee, Gregory A. |
author_sort | Hsu, Ashley C. |
collection | PubMed |
description | The STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique has shown promising results for treating type B aortic dissections, but the potential exists for fatal adverse effects. We present a case of infrarenal aortic rupture while using a compliant balloon to balloon mold the true lumen inside previously placed bare metal stents during the STABILISE technique. Caution is advised for providers who wish to perform the STABILISE technique, and we recommend using a semi-compliant balloon sized to the smallest total aortic diameter to mitigate the risk of rupture. |
format | Online Article Text |
id | pubmed-10665655 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-106656552023-09-29 Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique Hsu, Ashley C. DiBartolomeo, Alexander D. Han, Sukgu M. Fleischman, Fernando Magee, Gregory A. J Vasc Surg Cases Innov Tech Case report The STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique has shown promising results for treating type B aortic dissections, but the potential exists for fatal adverse effects. We present a case of infrarenal aortic rupture while using a compliant balloon to balloon mold the true lumen inside previously placed bare metal stents during the STABILISE technique. Caution is advised for providers who wish to perform the STABILISE technique, and we recommend using a semi-compliant balloon sized to the smallest total aortic diameter to mitigate the risk of rupture. Elsevier 2023-09-29 /pmc/articles/PMC10665655/ /pubmed/38023324 http://dx.doi.org/10.1016/j.jvscit.2023.101338 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case report Hsu, Ashley C. DiBartolomeo, Alexander D. Han, Sukgu M. Fleischman, Fernando Magee, Gregory A. Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique |
title | Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique |
title_full | Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique |
title_fullStr | Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique |
title_full_unstemmed | Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique |
title_short | Aortic rupture during STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique |
title_sort | aortic rupture during stabilise (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) technique |
topic | Case report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10665655/ https://www.ncbi.nlm.nih.gov/pubmed/38023324 http://dx.doi.org/10.1016/j.jvscit.2023.101338 |
work_keys_str_mv | AT hsuashleyc aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique AT dibartolomeoalexanderd aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique AT hansukgum aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique AT fleischmanfernando aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique AT mageegregorya aorticruptureduringstabilisestentassistedballooninducedintimaldisruptionandrelaminationinaorticdissectionrepairtechnique |